background image

 

 
 
 

Summary of Contents for 8670-5WB

Page 1: ......

Page 2: ...nting and Routing Detail 8 o Figure 3 Electrical Installation Detail 9 o Figure 4 Cabinet and Base Dimensions 10 Timer setup 11 15 o SSAC Setup 11 o IDX Setup 12 o Infitec Setup 13 o Timer Settings Chart 14 o Typical Timer Settings 15 Programming the Remote Start System 16 Maintenance 17 Parts Breakdown 18 20 o 8670 5WB 18 o 8778A 1 19 o 22002 51A 20 Schematics 21 o S8670 5WB 21 Troubleshooting 22...

Page 3: ... can Key number can be found on the tag that comes attached to the keys There may be more than one key number depending on unit Please keep this information with your records MODEL _________________________________________ SERIAL _________________________________________ KEY NUMBER S _________________________________ DATE PURCHASED _______________________________ DISTRIBUTOR ______________________...

Page 4: ...AC 60Hz 14 AMPS 1 5 HORSEPOWER ONE CYLINDER ONE STAGE OIL LESS SCFM PSI 6 0 5 20 4 1 40 3 1 90 2 9 100 2 1 125 MAX PSI TEMPERATURE RANGE 10 DEGREES F TO 100 DEGREES F MOTOR 1 5 HP 1725 RPM CAPACITOR START NEMA 56 FRAME AUTOMATIC THERMAL OVERLOAD NO LUBRICATION REQUIRED ON MOTOR OR COMPRESSOR ...

Page 5: ...TIME INCORRECTLY GENERAL MECHANICAL ALL DIMENSIONS IN DRAWINGS ARE IN INCHES MOUNTING STUD SIZE 3 8 X 16 UNC X 1 4 MINIMUM CONCRETE REQUIRED AROUND MOUNTING STUD 18 MINIMUM PAD RECOMMENDED FOR BUMPER CLEARANCE FOR GASOLINE DISPENSING LOCATIONS A MINIMUM 18 HIGH PAD ABOVE THE DRIVEWAY 20 FOOT HORIZONTAL CLEARANCE FROM THE EXTERIOR ENCLOSURE OF ANY GASOLINE DISPENSING PUMP ELECTRICAL SERVICE Dedicat...

Page 6: ...DO NOT install the cover at this time 4 Mount cabinet to base securely as shown in Figure 2 using only the four 5 16 18 X bolts DO NOT install the 20 X bolts at this time 5 Using Figures 2 3 install electrical and water services to the unit and run air and water lines to the inputs of their respective hose reels Air line should run between the output of the unloader valve and the input of the air ...

Page 7: ...8670 5WB Manual 10 2006 7 Figure 1 Installation footprint for 6025 hose reel base ...

Page 8: ...8670 5WB Manual 10 2006 8 Figure 2 Mounting and routing detail ...

Page 9: ...8670 5WB Manual 10 2006 9 Figure 3 Electrical installation detail ...

Page 10: ...8670 5WB Manual 10 2006 10 Figure 4 Cabinet and hose reel base dimensions ...

Page 11: ...mer and coin settings For custom settings follow the steps below 1 Figure the total time your vac will run in minutes and divide that number by the number of coins to start This is your time per coin Round up or down to the nearest tenth of a minute 2 Subtract the largest value switch initially 6 4 from your time per coin a If the resulting number is zero move the switch to the on position and set...

Page 12: ...r using Table 1 ignore settings for switches 1 and 512 For custom settings follow the steps below 1 Figure the total time your vac will run in seconds and divide that number by the number of coins to start This is your time per coin Round up or down to the nearest even number 2 Subtract the largest value switch initially 256 from your time per coin a If the resulting number is zero move the switch...

Page 13: ...ow the steps below 1 Figure the total time your vac will run in seconds This is your total run time Round up or down as desired 2 Subtract the largest value switch initially 512 from your total run time a If the resulting number is zero move the switch to the on position and set all remaining un set switches in the off position Your timer is now set b If the resulting number is positive move the s...

Page 14: ... 0 8 48 sec 0 9 54 sec 1 0 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 2 0 2 5 3 0 3 5 4 0 4 5 5 0 5 5 6 0 6 5 7 0 7 5 8 0 8 5 9 0 9 5 10 0 0 1 x x x x x x x x x x x x x x x x x x 0 2 x x x x x x x x x x x x x x x x x x 0 4 x x x x x x x x x x x x x x x x x 0 8 x x x x x x x x x x x x x x x x 1 6 x x x x x x x x x x x x x x 3 2 x x x x x x x 6 4 x x x x x x x x 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 x x x ...

Page 15: ...N 50 4 1 2 MIN 2 4 8 256 50 5 MIN 2 4 16 128 50 5 MIN 0 1 0 8 1 6 50 5 MIN 4 8 32 256 50 5 1 2 MIN 2 4 32 128 50 5 1 2 MIN 50 5 1 2 MIN 2 8 64 256 75 2 MIN 8 32 75 2 MIN 75 2 MIN 8 16 32 64 75 2 1 2 MIN 2 16 32 75 2 1 2 MIN 75 2 1 2 MIN 2 4 16 128 75 3 MIN 4 8 16 32 75 3 MIN 0 2 0 8 75 3 MIN 4 16 32 128 75 3 1 2 MIN 2 4 64 75 3 1 2 MIN 75 3 1 2 MIN 2 16 64 128 75 4 MIN 16 64 75 4 MIN 75 4 MIN 16 3...

Page 16: ...circuit board in place 3 Press and release the Learn Code Button LED indicator will blink at a rate of two times per second 4 Press the Transmitter Button once The indicator light should now be on continuously 5 Press the same Transmitter Button again The indicator light should now turn off The remote start system should now be programmed Note You must perform steps 3 5 within 30 seconds If the LE...

Page 17: ... on top of valve and remove coil cover and coil Then using a flat head screwdriver remove the piston housing Clean out any debris on the piston and in the piston housing and reassemble the valve Clean the outside portion of the cabinet with a stainless steel polish DO NOT use any abrasive cleaners steel wool or any kind of brush to clean the exterior Doing so could possibly scratch or damage the f...

Page 18: ...8670 5WB Manual 10 2006 18 ...

Page 19: ...8670 5WB Manual 10 2006 19 ...

Page 20: ...8670 5WB Manual 10 2006 20 ...

Page 21: ......

Page 22: ...move the wires leading to the timer from the coin mech and tap them together one time for each coin necessary to start the timer If machine starts replace the coin mech Remote Starter Test transmitter batteries and replace if needed Remove receiver cover and verify proper voltage across terminals 1 and 3 24VAC If proper voltage is present and transmitter batteries are good follow instructions to p...

Reviews: