DESCRIPTION OF KEYPAD (

Access module with segments

For the most convenient control and status indication the JABLOTRON 100 system offers various types 

of access modules. Controlling (setting, unsetting and other available functions) can be done just by pressing 
one button on the two-button segments. Moreover, the buttons are backlit in order to clearly indicate the 
segment status at fi rst sight. The segments can also be used to control various devices – heating, window 
shutters, gates, etc. An arbitrary number of segments can be used as needed.   

Continuous yellow

PARTIALLY SET 

Flashes red

ALARM

Continuous green

EVERYTHING OK

Flashes green

CONTROL

Continuous yellow

FAULT

When controlling the system using buttons on segments the command must be confi rmed  with 

authorization. This can be done by applying an RFID card or by entering a code on a keypad. Authorisation
can be done by RFID cards / tags of the OASiS system, Azor system or any other one working with EM 
125kHz. If a high security level is required, it can be set so that the card authorization must be confi rmed 
by entering an access code on a keypad. On the other hand mainly for home automation usage the control 
via segments can be simplifi ed by setting that for setting or controlling devices no authorization is required. 
This feature can be used e.g. to control window shutters on the house using a keypad. 

Another advantage of controlling the system using segments is the possibility to carry out multiple 

commands at the same time – it is therefore possible to set the house section with one segment, set 
the garden section alarm with the second one and unset the garage section with the third one. Only one 
authorization is required after selecting all options via segment buttons. 

The authorization code entered on a keypad can consist of up to seven characters. It includes a prefi x 

(one to three digits) a separating star and a four-digit code. It can thus be for example 123*1234 or 1*1234. 
This code can be simplifi ed for buildings with only a few users by omitting the prefi x. Only a four digit code 
is then used.

Card reader

Keypad with a reader

Keypad with a LCD display 

and a reader

Access module

CARD READER / KEYPAD

Continuous red

SET / ON

Flashes red

ALARM / ALARM MEMORY

Continuous green

UNSET / OFF

Flashes green

ENTRY DELAY

Summary of Contents for 100

Page 1: ...card authorization must be con rmed by entering an access code on a keypad On the other hand mainly for home automation usage the control via segments can be simpli ed by setting that for setting or...

Page 2: ...want to unset the alarm When I enter the building the entrance delay is triggered It is indicated by an uninterrupted beeping sound and repeated ashing of the green LED on the button I press the ashi...

Page 3: ...is necessary to press the button twice in the rst step When you press the button for the rst time the LED starts ashing yellow and it turns red after the second press When the authorization is con rme...

Page 4: ...MMAND Command wording can be set according to the actual situation e g SUNBLINDS DOWN It can be set that no code is required before the command You can also enable control by dialling in from an autho...

Page 5: ...orise your self By pressing buttons or you can read the basic list of the event memory In the upper status bar the time when the event occurred is visible By pressing ENTER on a selected event it show...

Page 6: ...display shows you the Users and Devices settings only for Administrator authorisa tion Choose which settings you want to change Users or Devices and con rm the selection by pressing ENTER User setting...

Page 7: ...keypad rmware LU60x10 and higher and control panel rmware LJ60408 or MD60408 and higher Lower rmware only makes the menu partially available Firmware upgrades can be done by the installer 3 During ins...

Page 8: ...User manual JABLOTRON 100 For questions and further information contact your installer MLJ57102 NOTES...