The AC-83 wireless output relay module 

1 / 2 

MJT51403 

The AC-83 wireless relay output module

The AC-83 is a component of Jablotron’s Oasis system. It provides 3 

relays which can be controlled by radio signals. The AC-83 is mains-

powered. The device is suitable for heating control via signals received 

from wireless thermostats of the TP-8x series. You can use the device 

in the following combinations: 

o

  With PGX and PGY outputs of a JA-8x control panel equipped 

with a radio module (for switching between heating modes). 

o

  With RC-8x remote controls (for switching between heating 

modes). 

o

  With JA-80M or JA-82M magnetic door-detectors (for heating 

enablement or disablement). 

 

 

 

1

2

3

4

R

A

D

IO

m

ax

 F

 5

 A

 / 2

50

V

buttons

LEDs

fuse

max 5 A

X

Y

holes to route

a fixing belt

 

 Installation 

 

Installation of this module shall only be undertaken by 

technicians holding a certificate issued by an authorized 

distributor. 

Warning: this device is galvanically connected to the 

mains.

 

Open the module’s cover (1 screw) and take out the circuit board (2 

tabs). Install the back part of the housing to the desired place, re-install 

the circuit board, connect the wires and enroll the desired wireless 

devices. 

 Terminals 

L, N, N 

Power 230V/50Hz (N, N is a pair of connected terminals) 

Lp 

Normally open contact for the Z common relay 

L1

 

Normally open contact for the X output relay 

L2

 

Normally open contact for the Y output relay 

All normally open contacts are fused by a common 5 Amp fuse – 

the total combined consumption of the terminals must not exceed 

this limit. 

 

Warning: The mains power output does not 

provide mains isolation for safety!!

 

 

 Function description 

The 

X and Y relays 

are totally independent. Jablotron TP-8x 

wireless thermostats can be enrolled to them individually using the X 

and Y enrollment buttons. In parallel to thermostats, either 

remote 

controls 

or a 

JA-80 control panel 

can be enrolled (however, these 

devices cannot be used in a simultaneous combination) to control 

switching the thermostat modes. In addition to the previously 

mentioned, wireless magnetic door-detectors can be enrolled and 

subsequently used to control the disabling of the heating. 

The 

Z relay 

is designed to control a heating circulation pump. It 

reacts to the logical OR sum of the X and Y relays – the Z output is 

closed if, and only if, at least one of the X or Y relays is closed. 

All three relays are used in combination to provide “

pump cleaning

”. 

This function is realized by the simultaneous activation of the X, Y and 

Z relays for 6 minutes every 7

th

 day. This is especially 

useful in the 

summer

, when the heating system is out of operation. By such 

activations a reduction of sediments is achieved in the heating system 

and in the pump in particular. The function is not optional – it cannot be 

disabled. 

 Enrollment procedure  

  Up to 8 wireless devices (thermostats, magnetic door-detectors, 

control panel, remote controls) can be enrolled to each X or Y relay. 

  Use the 

X or Y button 

depending on which relay you want to enroll 

a device to. 

  Enter 

enrollment mode 

(this is indicated by red LED No. 2 or 4 

flashing) by pressing the button. 

 

Use a safe insulation tool for button handling.

 

 

Activate the device’s transmitter 

while the LED is flashing, as 

follows: 

o

 

Thermostat 

(should be enrolled first) – connect its battery up (if 

it has already been connected, first disconnect it, and then wait 

10 seconds). 

o

 

Control panel PG output 

– key in 299 in service mode. 

o

 

Key fob 

– press a button. 

o

 

Magnetic door-detector 

–  connect its battery up (if it has 

already been connected, first disconnect it, and then wait 10 

seconds). 

 

Enrollment is confirmed 

by a short flash from all AC-83 indicators. 

  If 

no enrollment signal has been received within 10 sec., 

enrollment mode automatically ends. 

  If you wish to enroll 

another device

, repeat the above enrollment 

procedure. 

Notes: 

  An overview of applicable control devices is provided in the table 

below together with their enrollment methods and basic 

descriptions of use. 

  If a device does not enroll, either it is too far from the receiver, or 

too close, or the maximum number of devices (= 8) has been 

exceeded. 

  Each transmitting device (keyfob, detector, control panel, etc.) can 

be enrolled to an unlimited number of different receivers. 

  Devices are enrolled to a non-volatile memory, so the AC-83 will 

not forget them if its power is disconnected. 

 

Control 

device 

Enrolled by 

Notes 

PGx output 

on the 

control 

panel 

Keying in 

299 in 

Service 

mode 

switching between heating modes (anti-

freeze / temperature regulation) 

- cannot be used in combination with 

remote controls 

Remote 

control 

Pressing any 

button 

switching between heating modes (anti-

freeze / temperature regulation) 

- cannot be used in combination with a 

control panel 

Magnetic 

door-

detector  

Inserting a 

battery 

sensor activation (door or window 

opening) disables standard temperature 

regulation mode  

- cannot be used in combination with 

remote controls  

 

 Use with TP-8x thermostats 

  If a single thermostat is enrolled to a relay without any other 

devices enrolled in parallel, the relay will switch the heating on or 

off, according to signals from the thermostat. 

  If multiple thermostats are enrolled, the corresponding relay 

switches on if at least one of the thermostats requires the heating to 

be switched on. 

  The enrollment of a thermostat to a relay is indicated by green LED 

1 for relay X and green LED 3 for relay Y. 

  Heating activation is indicated by red LED 2 for relay X  and red 

LED 4 for relay Y. 

 

Other devices can be combined 

with a thermostat and all be 

enrolled to the same relay (a total of 8 devices, including the 

thermostat).  

 

 

 