JA-10E BUS keypad 

JA-10E BUS keypad 

1 / 2 

MNX51101 

The keypad is a component of the 

JA-10

 system used to control  

the control panel and display its current status.  Using an external 

input a door detector can be connected to the keypad

.

 

It  is  necessary  to use this manual in combination with  

the JA-10 installation and user manuals. 

The  keypad  contains 4 function buttons  (5), an LCD display (3),  

a system indicator (2), status indicators A, B, C, D (1), a keypad with 

an RFID chip card/tag reader (4). 

Figure 1 : 1 – status indicators; 2 – system indicator; 3 – LCD display;  

4 – keypad and the RFID reader; 5 – function buttons A, B, C, D;  

6 – keypad opening tab; 7 – detachable  BUS terminals; 8 – tamper 

contact; 9 – production number 

Installation 

1.  Open the keypad housing

 

by pressing the tab on the bottom

(6) using a screwdriver. The tab is also accessible from

the front after opening the keypad cover.

2. 

Break away a hole in the plastic base, run the cable through

and screw the plastic back on a  selected place. Connect

the cable to the BUS terminals (7). For easier installation you

can detach the BUS terminals, connect the cables and

re-attach them.

3.  Insert the keypad back into the plastic base. Make sure

the conductors do not touch the tamper contact spring. 

4. Proceed according to the control panel installation manual.

Basic procedure: 
a. When the device is switched on, the system indicator (2) will

start flashing yellow repeatedly to indicate that the keypad

has not yet been enrolled to the system. 

b. Open the 

N-Link

  software, select the required position

in the 

Devices

 window, and click on the 

Enroll

 button which

will open a 

Device information

 dialogue window.

c.  Click on 

Scan/add new BUS devices

 

which will display a list 

of connected unenrolled devices. Double-click on the device

you want to enroll – the JA-10E in this case. 

d. The keypad is now enrolled and the yellow LED indicator

switches off.

Notes: 

The keypad can also by enrolled by opening the enrollment

mode (the Enroll button in the Devices tab of the N-Link SW)

and pressing the keypad’s cover or the tamper contact.

Enrollment is also possible by entering its production code (9)

in the N-Link software or using a bar code scanner. All

numbers stated under the bar code must  be entered (e.g.

1400-00-0000-0001).

Installation of a magnetic contact 

The keypad supports connection of a door detector. The IN input 

reacts to being disconnected from the GND contact. The control 

panel’s reaction to an activated IN input is configurable in the N-Link 

SW. 

Figure 2: connecting a magnetic contact 

Setting the properties 

Go to the 

Devices 

window in the N-Link software. When you are 

at the keypad position, click on the 

Internal settings

 option which will 

display a dialogue  window with all properties. Internal settings are 

separated into 2 basic tabs: 

Function

 and 

Settings

Function tab: 

Day and time 

– displays the current time in the top-right corner of the 

display 

The system is not prepared to be Set

  –  indicates an obstacle 

preventing setting the control panel. 

User  defined  text

  –  enables showing any text, for example the 

phone number of an installer company, etc. 

Button  function 

–  On the left is a selection of button functions.  

On the right is a selection of Sections or PG outputs to which  the 

functions will be assigned. A function button can be assigned with 

these functions: None, Unsetting/setting, Unsetting/Partially setting, 

Unsetting/Partially setting/Setting, Section indication, Panic, Fire, 

Audible panic, Medical Troubles, PG ON/OFF,  PG ON, PG OFF, 

PG indication, PG indicates inversely, Common functional button 

Authorization

 – Setting and Unsetting requires user authorization. 

When this parameter is disabled the function buttons can be operated 

without authorization, however this does not apply to  Unsetting  

a  section which always requires authorization. Both ON and OFF 

statuses of PG outputs can be configured to be operated with or without 

authorization  

Sections controlled by authorization

 – selection of sections which 

can be controlled by authorization (using an RFID chip or a code) 

PG Control – 

selection of PG outputs which can be controlled by 

authorization (using an RFID chip or a code)

 

Logo – 

the keypad can display a black and white picture of 128x64 

pixels (such as a company logo etc.) which stays on the screen for  

25 seconds after the last keypad operation. 

Import 

– enables copying settings from other keypads of the same 

type which have already been enrolled.  For example, this can be 

utilized when the building has multiple entrances and it is necessary 

for all keypads to have identical functions. In addition, this function 

can also be used when replacing a faulty keypad with another. The 

Import button provides the history of keypad settings on a position of 

a particular device. 

Setting tab: 

Acoustic indication of selected sections: 

Higher volume

  –  Increased  volume of indication  (It does  not 

apply to alarms). 

Alarms

 – Indicates alarms (sounds a siren). 

Entrance delay

 – continuous sound during the entrance delay 

Exit delay 

– slow beeping (1/sec) 

Exit delay when partially set

  –  slow beeping (deactivated

by default) 

Button status change 

 

beeps once when a status is changed

 

Function:

Optical indication setting:

1.

Indicates permanently

  –  the keypad  indicates  permanently.

When the mains electricity is disconnected  it indicates

the same way as option 3. When mains electricity is restored

the keypad indicates permanently again. 

2.

Section/PG status change on keypad

  –  The status

change  of a section/PG  is indicated by  a  specific  function

button  and a status indicator. Entrance delay and alarms

are indicated by all function buttons and status indicators.

3.

Section/PG status change on button

 – The keypad indicates

after a change of the section/PG status, entrance delay and

alarm only by a particular button and a section indicator.

Always switch the power off before 

connecting the keypad to the BUS.

 