The JA-114E Bus access module with LCD, keypad and RFID 

The JA-114E Bus access module with LCD, keypad and RFID 

 

MLU51105 

The keypad is a component of the 

JABLOTRON

 

JA-100

 system

Its

 

modular architecture enables users to create a combination whose size 
of  installation  perfectly  meets  their  needs.  The  device  should  be 
installed  by  a  trained  technician  with  a  valid  certificate  issued  by 
authorized distributor.

 

The keypad comprises a display, an RFID card / chip reader and the 

first control segment (1). JA-192E segments can be used to extend the 
JA-114E  unit  by  the  required  number  of  segments  (the  max.  allowed 
amount is 20 on one unit). The tilting keypad cover (6) can be removed 
if the user prefers permanent access.

 

 

 

Figure: 1 

– control segment; 2 – segment buttons; 3 – backlit activation 

button; 4 

– LCD; 5 – keypad module with RFID; 6 – tabs for opening; 

7 - cover screws 

 

 

Figure: 8 

– control segment connector; 9 – production code;  

10 

– bus terminals; 11 – tamper contact 

Installation   

1. 

Gradually  press  the  four  tabs  (6)  on  the  sides  and  release  the 
keypad from the plastic base. 

 

2. 

When  installing  more  control  segments,  first  remove  the  socket 
cover on the 1

st

 segment. 

 

3.  Remove  the  plastic  windows  from  the  segments  (by  levering  on 

both sides of the segments near the buttons). 

4. 

Always connect the segment wires to the connector of the previous 
segment and click them into each other (we recommend coiling the 
wires  by  turning  the  segment  by  360° 

–  this  will  prevent  any 

possible damage to the  wires between the plastic parts). Use this 
method to install all the required control segments. Finally, push the 
socket cover in. 

 

5. 

Push  the 

cable  through  the  plastic  base  and  attach  it 

to  the 

selected  place  together  with  the  segments 

using  screws.

  If 

multiple  control  segments  are  required,  attach  them  onto  the  wall 
using screws as well (use the number of screws required).

 

6. 

Connect the bus cable to the bus terminals (10). 

 

 

When connecting the module to the bus, 
always switch the power off.

 

7.  Connect the segment wires to the internal connector of the keypad 

(8).  

8.  Insert the keypad into the base. 
9.  Proceed  according  to  the  control  panel  installation  manual.  Basic 

procedure: 

a. 

When the device is switched on, the yellow LED starts flashing 
repeatedly  to  indicate  that  the  keypad  has  not  been  enrolled 
into the system. 

 

b.  Go  to  the 

F-Link

  program,  select  the  required  position  in  the 

Devices

  window  and  launch  the  enrollment  mode  by  clicking 

on the 

Enroll

 option. 

c. 

Press the  backlit activation  button (3)  above the screen 

– the 

keypad is thus enrolled and the yellow LED indicator goes off.

 

 

10. 

When you have completed the installation, insert descriptive labels 
onto the segment plastic windows and close them. Label printing is 
a  part  of  the  F-Link  program  (

Devices

  window,  at  the  keypad 

position 

– 

Internal settings

).

 

 

Note: To comply with the EN 50131-3 norm it is necessary to fix the 
cover  tab  by  the  screws  from  the  accessories.  In  picture  no  1  the 
cover tabs are fixed by the arrows. 

 

 

Figure: Inserting a label into a control segment 

Setting the properties 

Go to the 

Devices 

window in the F-Link program. When you are at 

the  keypad  position,  use  the 

Internal  settings

  option.  The  particular 

unit is displayed and it is possible to set its properties. It is possible to 
set  the  required  functions  for  individual  segments  (control  of  sections, 
section status signalling, alarm triggering, PG output control, PG output 
status signalling, etc.). More details are available in the F-Link program. 

A common segment (up to 2 of them allowed on one keyboard) simulates 

the  simultaneous  pressing  of  several  segments  which  are  placed  on  this 
keyboard  and  which  control  sections.  The  selection  of  sections  which  are 
assigned to the common segment is performed by F-Link SW, the 

Devices

 

window. At the keyboard position select 

Internal settings / and Common 

segment 1 (2) 

and mark the segments which will be operated en bloc. The 

selected sections will be set / unset after pressing a button on the common 
segment. If the states of the segments which are operated by the common 
segment are mixed, then only the segments that need changing will be set / 
unset.  If  partial  setting  is  enabled  for  some  segments,  then  the  common 
segment respects this: 1 st. press = partially setting, 2

nd

 press = full setting. It 

is not suitable to combine a common segment with a common section 

The indication of the common segment is: all segments set = green, some 

set (partially set) = yellow, all sections fully set = red.  

Unit modifications  

If you need to change the unit’s individual segments, it is possible to 

separate them by levering the corresponding separating gaps from one 
side (sideways from the buttons). 

 

 