JA-120PC (90) PIR motion BUS detector with a 90° verification camera

JA-120PC (90) BUS PIR motion BUS detector with a 90° verification camera

1 / 2

MMP53102

This device is a bus component of the 

JABLOTRON JA-100 

system.

It serves for the detection of human movement in building interiors and visual 
alarm confirmation. The camera takes colour photos with a resolution of up to 
640x480 pixels. The camera trigger follows detected movement, which 
ensures that the cause of the alarm is always recorded. The camera 
is equipped with a visible flash for taking photos in the dark. The images are 
saved in the internal memory of the detector and then they are forwarded 
to the control panel and from the control panel they can be sent 
to MyJABLOTRON, ARC and a user. The detector can also take a picture 
by request. The detector should be installed by a trained technician with 
a valid certificate issued by an authorised distributor.

Installation

The detector can be installed on 

the wall or in the corner of a room. 
There should be no objects that can 
quickly change temperature (e.g. 
heating appliances) or which move 
(e.g. curtains hanging above 
a radiator, robotic vacuum cleaners) 
or pets in the detector’s field of sight. 
It is not recommended to install the 
detector opposite windows 
or in places with intense air circulation 
(close to ventilators, heat sources, air 
conditioning outlets, unsealed doors, 
etc.). There should be no obstacles in 
front of the detector which might 
obstruct its view of the protected area.  

Figure: 1 – flash for illumination; 2 – camera lens; 

3 – PIR detector lens; 4 – cover tab;

Avoid installation too close to a ceiling. Using 
the flash may cause over-exposure of the scene 
due to reflections. 

1.

Open the detector cover (by pushing the cover tab (4)). Avoid touching 
the PIR sensor inside (14) – you could damage it. 

2.

Take out the PCB – it is held by a tab (9).

3.

The recommended detector installation height is 2.5m above the floor. 

4.

Attach the plastic base to the wall using screws (vertically, with the cover 
tab facing downwards).

5.

Re-insert the PCB and connect the BUS cables to the terminals (11)

6.

Plug the connecting cable (6) into the connector on the PCB.

Always switch the system power off before 
connecting the detector to the system BUS.

Figure: 5 – Camera module; 6 – connecting cable; 7 – production code; 

8 – red LED indicator; 9 – PCB tab; 10 – yellow LED indicator; 

11 – BUS terminals;  12 – BUS cable; 13 – tamper contact; 14 – PIR sensor; 

15 – Micro SD memory card; 16 – yellow LED Micro SD card indicator

7.

Proceed according to the control panel installation manual. Basic 
procedure:
a.

When the device is switched on, the yellow LED indicator (10) starts 
flashing repeatedly to indicate that the module has not been 
enrolled into the system.

b.

Go to the 

F-Link

software, select the required position 

in the 

Devices

tab and launch the enrollment mode by clicking 

on the 

Enroll

button.

c.

Press the 

Scan/add new BUS devices

button, select 

the JA-120PC 90° detector and confirm by double clicking on it. 
The detector will be enrolled and the yellow LED indicator (10) will 
go off. 

d.

If the detector is enrolled as a first camera PIR or a control panel 
is not connected to an external mass storage, F-Link shows 
a dialogue window with the question: “Enable image transfer 
to external storage?” We recommend enabling this option with 
the agreement of the customer and confirming this acceptance 
by recording it in the system service log with his signature. 

Note

: If the transmission is not enabled, images will be saved in the 

internal memory of the detector and the control panel. Then it won’t 
be possible to send images to users’ cell phones and e-mails.

8.

Close the detector cover and test its functionality.

Notes

:

-

The detector can be also enrolled by pressing the front tamper contact 
(13).

-

Or the detector can be enrolled by entering the serial number (7) 
in the F-Link software (or using a bar code reader). Enter all digits 
located below the bar code (1400-00-0000-0001).

-

If you want to remove the detector from the system, erase it from 
its position in the control panel.

-

In order to comply with the EN 50131-2-4 norm, the cover tab (4) must 
be secured with the supplied screw.

Detector internal settings

Settings can be made using 

F-Link

software. In the 

Devices

tab use 

the 

Internal settings

option on the detector’s position to open a dialog 

window where you can configure the settings (

*

default settings):

LED movement indication:

Disables/*Enables

movement indication with 

the red LED (8) during operation. Always indicates service mode.

PIR immunity level:

Defines false alarm immunity. The 

*Standard

level 

combines basic immunity with a rapid reaction. The Increased level provides 
higher immunity but the detector reaction is slower.

LQ photo quality:

Standard*

quality uses optimized compression in order 

to achieve the fastest possible transfer to the ARC or to the end user 
in MyJABLOTRON. The goal is achieving alarm verification in the fastest time 
possible. If the quality is switched to 

Extended, 

the system will use lower image 

compression which will at least double the time necessary to transfer the image 
(depends on the conditions of the captured scene). Change the quality only if 
the LQ image does not have the quality required by the customer – it may depend 
on the captured space. It is not recommended when there are more verification 
detectors in the premises which may take images at the same time.

Taking photos during alarms:

No flash, *With flash

Flash intensity: 

Low, *Medium, High – if the captured scene is over-exposed 

(e.g.in a small room), the intensity of the flash can be decreased. It can be 
increased for larger spaces.

PG output reaction:

You can select PG outputs, whose activation will trigger 

taking a picture (

* No

, camera does not react to PG). For further info see

Installation recommendations, cautions.

Taking a photo by PG activation:

No flash, *With flash

Taking photos during entrance delay:

*No flash, With flash

Send pre-alarm photos:

This option is not available when the 

Extended 

LQ 

photo quality is selected due to more than double size of the photo and therefore 
longer transmission time. When this parameter is enabled the detector will send 
photos even when the detector is configured with repeated or confirmed reaction 
and the alarm has not been confirmed. During every entrance delay, up to two 
photos can be taken when the detector is triggered even when the system has 
been unset properly. 

This option will noticeably increase the volume of data transferred 

to MyJABLOTRON or external mass storage. If the system is unset (alarm 
is triggered), the images taken during the entrance delay will be sent automatically 
regardless of this option.

Test:

takes a test photo (LQ) with a flash and F-Link displays it. When the 

Detail

button is pressed, the F-Link software shows the picture in a 640x480 px 

resolution. Photos are sent to the external mass storage (provided that transferring 
is enabled). 

To set the JA-120PC (90) detector to comply 
with security grade 2 or other requirements use 
F-Link SW, Parameters tab and the option 
“System profiles”.

Camera and basic reactions

The process of how the camera takes pictures depends on the settings 

in the 

F-Link

software

– under the 

Devices

tab. Choose a type of 

Reaction

on the detector’s position.

Instant:

During an alarm triggered by the detector, the camera can be activated 

up to 3 times (then it will be auto-bypassed). Each activation, depending 
on the detected movement, takes 2 photos maximum. Photos are sent to 
the control panel (6 photos maximum). 

Delayed:

The first activation (entrance delay) takes up to 2 photos depending 

on the detected movement and saves them into the internal memory 

(Send pre-

alarm image 

disabled

)

. When alarm is triggered, photos are sent from the internal 

memory to the control panel. Then the behaviour is the same as with an instant 
reaction (8 photos maximum). 

Warning

: When the Device autobypass/3rd alarm is enabled (located 

in 

Settings/Parameters

) taking photos is blocked after the 3rd alarm. During 

each alarm the detector can be triggered up to three times. This way, 

Reviews: