JA-150E Wireless keypad 

JA-10E BUS keypad 

1 / 3 

MLU25301 

The keypad is a component of the 

JABLOTRON 100

 system used  

to control the control panel and display its current status. Using an external 
input a door detector can be connected to the keypad

.

 

It is necessary to use this manual in combination with 

 

the 

JABLOTRON 100

 installation and user manuals. 

The keypad contains 4 function buttons (5), an LCD display (3), 

a system indicator (2), status indicators A, B, C, D (1), a keypad with 
an RFID chip card/tag reader (4). 

 

Figure 1: 1 – status indicators A,B,C,D; 2 – system indicator; 3 – LCD 

display; 4 – keypad and the RFID reader; 5 – function buttons A, B, C, D;  

6 – keypad opening tab; 7 – batteries; 8 – detachable  BUS terminals;  

9 – tamper contact; 10 – mini USB connector; 11 – production number. 

Installation 

1.  Open the keypad housing

 

by pressing the tab on the bottom (6) 

using a screwdriver which will release the keypad from its back part.  

2. 

Screw the back part on a selected place. We recommend using all 
four mounting holes and screws to attach the plastic base.  
To meet the criteria of EN 50131 grade 2 the plastic base must  
be screwed by at least two screws using the mounting hole next  
to the tamper contact hole and the mounting hole in the diagonal 
corner. 

3.  Insert two CR123A lithium batteries in the keypad. 
4.  Insert the keypad back into the back part and lock the bottom tab 

using the little screw.  

5.  Proceed according to the control panel installation manual. 

Basic procedure: 

a.  The JA-111R radio module must be installed in the control 

panel. The keypad must be in its communication range. 

b.  When the device is switched on, the system indicator (2) will 

start showing yellow light to indicate that the keypad has not yet 
been enrolled to the system.  

c. Open 

the 

F-Link

 software, select the required position in the 

Devices

 window, and click on the 

Enroll

 button which will open 

the enrollment mode. 

d.  Press the keypad cover to enroll the keypad and the yellow 

LED indicator starts flashing (twice with pause) to indicate 
Service mode, which may take a few seconds. The enrollment 
signal can be sent by inserting the batteries in the keypad  
or pressing the tamper contact. 

Notes: 

 

Enrollment is also possible by entering its production code (11)  
in the F-Link software or using a bar code scanner. All numbers 
stated under the bar code must be entered (e.g. 1400-00-0000-
0001). 

Installation of a magnetic contact 

The keypad supports connection of a door detector. The IN input 

reacts to being disconnected from the common GND contact.  
The control panel’s reaction to an activated IN input is configurable  
in the F-Link SW.  

 

Figure 2: connecting a magnetic contact 

Setting the properties 

Go to the 

Devices 

window in the F-Link software. When you are 

at the keypad  position,  click  on  the 

Internal settings

 option which will 

display a dialogue window to configure its settings and function buttons. 
Internal settings are separated into 2 basic tabs: 

Function

 and 

Settings

The Function tab: 

Time

 – Displays the current time in the top-right corner of the display 

User text

 – Enables showing any text, for example the phone number 

of an installer company, etc. 

Temperature

 – Displays the temperature measured by one 

 

of the selected thermometers in the bottom-right corner of the keypad 
display. 

Buttons Function 

– On the left is a selection of button functions.  

On the right is a selection of Sections or PG outputs to which the functions 
will be assigned. A function button can be assigned with these functions: 
None, Set/Unset, Unset/Partially set, Unset/Partially set/Set, Section 
indication, Panic, Fire, Audible panic, Medical Troubles, PG ON/OFF, PG 
ON, PG OFF, PG indication, PG indicates inversely, Common function 
button. 

Authorization

 – Setting and Unsetting requires user authorization. 

When this parameter is disabled the function buttons can be operated 
without authorization, however this does not apply to Unsetting a section 
which always requires authorization. Both ON and OFF statuses 

 

of PG outputs can be configured to be operated with or without 
authorization.  

Import 

– Enables copying settings from other keypads of the same type 

and FW version, which have already been enrolled. For example, this can 
be utilized when the building has multiple entrances and it is necessary for 
all keypads to have identical functions. In addition, this function can also  
be used when replacing a faulty keypad with another. The Import button 
provides the history of keypad settings on a particular position 

 

of the device. 

Section selection

 – Selection of sections which can be controlled  

by authorization (using an RFID chip or a code) 

PG selection – 

Selection of PG outputs which can be controlled  

by authorization (using an RFID chip or a code)

 

The Setting tab: 

Acoustic indication of selected sections: 

Higher volume

 – Increased volume of indication (it does not apply  

to alarm). 

Alarms

 – Indicates alarm (sounds a siren). 

Entrance delay

 – Continuous sound during the entrance delay. 

Exit delay 

– Slow beeping (1x every second) 

Exit delay when partially set

 – Slow beeping (deactivated by default). 

Segment status change 

 

Beeps once when a status is changed.

 

Function: 

Optical indication setting: 

1. 

Indicates permanently

 – The keypad indicates permanently. 

When the mains electricity is disconnected it indicates the same 
way as option 3. When mains electricity is restored the keypad 
indicates permanently again. 

2. 

Section/PG status change on keypad

 – The status change  

of a section/PG is indicated by a specific function button 
and a status indicator. Entrance delay and alarms are indicated 
by all function buttons and status indicators. 

3. 

Section/PG status change on segment

 – The keypad indicates 

after a change of the section/PG status, entrance delay and alarm 
only by a particular button and a section indicator. 

4. 

Segment status change on keypad

 – The keypad indicates 

after a change of the section/PG status by a particular button and  
a section indicator. Entrance delay and alarms are indicated 
acoustically only.  

5.  Entrance delay/Alarms on segment

 – The keypad indicates 

entrance delays and alarms with a function button and a status 
indicator. Change of section/PG status is not indicated visually 
or acoustically.

 

6. 

Wake-up by pressing

 – The keypad starts to optically and 

acoustically indicate after the front cover has been opened and 
also when a key or a function button has been pressed.

 

RFID reader: 

In order to save energy we limit the RFID reader to function for 
3 seconds after pressing the keypad cover. The RFID reader can be 
also completely disabled. This setting applies to wireless keypads  
as long as they are permanently supplied by an external power 
supply, otherwise their RFID readers will always turn off automatically. 

Permanently ON

 – 

the RFID reader is always active. This works only 

when the 

Optical indication setting 

is set to the option number  

1 - Indicates permanently. 

Activated by pressing

 – When the keypad is activated the RFID 

wakes up for 3 seconds. 

Disabled

 – RFID reader is permanently disabled. 