The JA-151TH Wireless temperature detector

The JA-151TH Wireless temperature detector

1 / 2

MNG51308

The JA-151TH is a component of the 

JABLOTRON 100

system.

It serves for temperature measurement and forwarding measured 
data to MyJABLOTRON. MyJABLOTRON analyses and stores 
measured data for further use for instance the SMS reporting 
of exceeding temperature limits or to create graphs of measured 
temperatures.

All

functions are programmable

directly 

in MyJABLOTRON. The PG control function can be assigned 
to maximum of 2 thermometers per control panel. This product
should be installed by a trained technician with a valid certificate 
issued by an authorised distributor. 

Installation

Select the installation place according to the temperature 

measuring requirements. It is not recommended to install 
the detector near heat sources affecting measuring (heaters, 
electric fans, air conditioning outlets, fireplace inserts, etc.). 
The detector can also be installed in an outdoor environment but 
it has to be placed into a suitable box with a minimum of IP65 
housing, the JA-192PL-A for example.

Figure 1: 1 – cover tab; 2 – LED indication

1. Open the cover by pushing the tab (1).
2. Attach the plastic base to the required place using screws.
3. Follow the instructions in the control panel installation manual. 

Basic procedure:
a. Go to the 

F-link

software, select the required position 

in the

Devices

tab and launch the enrollment mode 

by clicking on the

Enroll

option.

b. The enrollment signal is transmitted when the battery 

is inserted into the detector.

4. Close the detector cover.

Figure 2: 3 – production code; 4 – activation button; 5 – battery

Note:

Enrolling the detector to the system is also possible with active 
enrolment mode by entering the production code (3) via 
the F-Link software. All digits in the production code are 
required (1400-00-0000-0001).

If you want to remove the detector from the control panel, erase 
it from its position.

Functions

The JA-114E and JA-154E series of keypads are able to display 

up to 2 current temperatures on the keypad screen. See the JA-10xK 
installation manual.

The detector has a fixed antifreeze temperature of +6 °C with ±1 °C 

hysteresis. Therefore the detector has an activation temperature 
of +5 °C. The deactivation temperature is +7 °C. 

Using the F-Link software, it is possible to configure the JA-10xK 

control panel’s reaction (PG output, 24h alarm, etc.) to react 
to temperature detector activation. Thus the selected PG output 
is controlled directly by the control panel.

All thermometer functions can be fully used in MyJABLOTRON. 

The registration procedure is described in the

Control panel installation 

manual.

MyJablotron

All thermometers and their measured values are stored and shown 

in the

Thermostats and Thermometers

tab in MyJABLOTRON. 

The temperatures are stored automatically every 5 minutes. 
The temperatures are displayed in a graph with an adjustable timeline. 
It’s possible to export data from the graphs in various formats for further 
processing. The graph function enables you to compare temperatures 
from two thermometers or different time periods (only available 
in the MyJABLOTRON mobile app).

The app offers the following functions:

PG control by measured temperature

Using MyJABLOTRON, it’s possible to configure activation of a PG 

output by a temperature measured by the thermometer. The selected 
PG output is controlled remotely from MyJABLOTRON therefore stable 
external communication is necessary for this function to work properly.
If this function is selected, the user can use a slider to configure 
the desired temperature which will activate the PG output. These 
settings are located in the 

Thermostats and Thermometer

tab.

Linking

the thermometer with a PG output is done by a service 

technician in the 

Installation management 

section

of

the

MyCOMPANY app. Select the control panel, enter the 

Devices

tab,

press the symbol of a gearwheel on the thermometer and select a PG 
output which should be controlled by the measured temperature. 
Use the slider to configure the desired activation temperature. 
This configured link is indicated by a PG symbol at the thermometer’s 
position.

Warning!

The controlled PG output must be configured to have 

ON/OFF

or 

Impulse

functions (configurable in the F-Link software). 

Notes:

Establishing the link and controlling the PG output by the measured
temperature can also be done in the MyCOMPANY and 
MyJABLOTRON mobile app.

This function can be configured for a maximum of 2 thermometers 
enrolled to the control panel (the sum of wireless and BUS 
thermometers).

Connection via GSM and LAN communicators is required in order 
to make sure that PG output control from MyJABLOTRON works 
properly.

Due to fact that PG outputs are controlled via an external app,

we cannot guarantee proper functioning under all 
circumstances

. When the connection with MyJABLOTRON is lost, 

the status of the PG output stays unchanged until the connection 
is re-established. This is why we recommend using a controlled PG 
output along with the IMPULS function set to an activation time 
of 2:00:00. The PG output will be controlled by commands from 
MyJABLOTRON. If the connection is lost, activation of the PG
output will be limited by the activation time of the IMPULS function.

The activation hysteresis of a PG output is +/- 1 °C. The PG output 
will be activated when the measured temperature is 1 °C lower than 
the activation temperature. Deactivation will occur when this 
temperature is exceeded by 1 °C.

Notifying

the user when the temperature exceeds the allowed 

range

You can set a higher and a lower temperature limit and a certain 

period of time of temperature monitoring for a selected thermometer 
in 

Settings 

Æ

Thermometer notification

. When one of these limits 

is exceeded or gone below then it’s reported by an SMS, an e-mail 
or push notifications if you use the MyJABLOTRON app. 

Battery replacement

The system sends a report automatically when the battery is low. 

During the battery replacement it is not necessary to switch 
the system to service mode (this detector has no tamper contact).

After taking out the battery, presses the activation button (4) 

to discharge the capacitors in the detector and then insert 
a new battery.

Apply the same procedure if you need to enroll the detector 

to a different control panel.