The JA-152J MS II Bi-directional two-button key fob 

JA-152J MS II 

1 / 2 

MMJ23100 

The JA-152J MS II is a component of the 

JABLOTRON 100 + 

system. 

It is designed to remotely control a security system, various appliances 

(using PG programmable outputs) or to trigger panic alarms and more. 

The remote control can also be 

enrolled to multipurpose relays such 

as the AC-16x series for direct relay 

control according to the pre-set 

mode. The remote is equipped with 

optical and acoustic indication. It 

checks its battery status and 

indicates when the battery is nearly 

discharged. 

The remote 

communicates via the Jablotron 

wireless protocol and is powered by 

a single power cell.  The remote 

takes up a single position  in the 

system. 

Figure:

 1 – LED indication; A, B – buttons,

 see their functions according to 

table 1. 

Enrolling the remote control to a control panel 

There must be a JA-11xR radio module installed in the control panel for 

the ability to work with a control panel. It occupies one position in the system. 

The remote can be enrolled to an arbitrary number of JABLOTRON 100 

systems. One pair of buttons can control several sections at the same time 

(common control)  and it can show the current status of the section or PG 

output. 

1. The control panel has to be in service mode.

2. Basic procedure:

a. Go to  the 

F-Link

  software, select the required position in the

Devices

 tab and launch 

enrollment mode

.

b. For transmission of an enrollment signal press and hold buttons

(A+B) simultaneously for at least 3 s (within this time the yellow

LED flashes rapidly).

c.  After 3 s the enrollment signal is sent and confirmed by one long

yellow LED flash. Release both buttons and close enrollment

mode.

To set the key fob to comply with security 

grade 2 use F-Link SW, Parameters tab and 

the option “Perform EN50131-1”. (See the 

JA-10xK control panel installation manual)

 

Notes: 

Enrolling the remote control to the system is possible by entering

the production code via F-Link software. The production code is on

the sticker with a bar code glued onto the battery holder inside the

remote. All digits in the production code are required

(example: 1400-00-0000-0001)

If you want to remove the remote control from the system (for

instance when someone has lost  it), erase it from the particular

address of the control panel.

Setting the properties 

Perform settings using 

F-Link

  software – 

Devices

  tab. Click on the 

JA-152J  MS II´s 

Internal settings

. Then a window appears 

automatically where you can set the following parameters: 

Functions of the buttons:

  set a particular function for the pair of 

buttons A-B (typically setting / unsetting, OFF / ON  switching of some 

appliance, etc.) or a function for each single button A, B (gate opening, 

garage door opening, etc.) and also for a double press of the remote. 

See the following table 1. 

Reaction for single button 

/

  (A / B) 

Reaction for pressing 

simultaneously 

+

(A + B)

 

 

None (button not used)

 

Copy PG

 

Change PG state

 

Silent panic ***)

 

Audible panic ***)

 

Health troubles

 

Report A, B, C, D

  None (button not used)

  Read status ***)

  Copy PG **)

  Change PG status

  Silent panic ***)

  Audible panic ***)

  Health troubles

  Report A, B, C, D

Reaction for pair of buttons (segment function) 

-

 

(A - B) 

  Unset / Set

  Unset / Partially set

  Unset / Partially set / Set

  Unset / Set with confirmation 

  Unset / Partially set with confirmation 

  Unset / Partially set / Set with confirmation 

  PG OFF / ON

Table 1. Button function options overview 

For each function selected for a remote control button it is necessary 

to select the appropriate PG or sections to be controlled or from which 

reports should be reported (panic, etc.). For  the  common  control 

of multiple sections  it 

is not recommended

  to operate a  common 

section, but to select the desired section in the remote control internal 

settings. 

Notes: 

*)

 

Once a button (with the “Copy PG” function enabled) is pressed 

and held, the activation signal is transmitted once every second. 

The function can be utilized to extend the duration of a PG output 

(said PG must have the “copy PG” function enabled). The aximal 

length of continuous transmission is 1 minute. 

**) 

The 

„Copy PG“ 

reaction to a double press can be used for a 1 s 

impulse only for the selected PG – double button pressing cannot 

send 1s activation signal repeatedly unlike single buttons. 

***)  The reactions of the buttons  which are not supported when the 

system is configured comply with security grade 2. 

****)  If there is a pre-set function for the pair of buttons A+B (typically 

Unset / Set section or PG OFF / ON), then that option also 

triggers the  option 

„Read status“

. If this  option is enabled the 

remote reacts to a double press by showing the current status of 

the section or PG. 

For all functions related to setting the sections, the  control panel 

follows the option 

Ways of setting

 selected in the Parameters tab. 

a. For 

„with confirmation“ 

types of setting  (see table 1),  for 

„set

with warning“ 

options  and 

„set with confirmation“ 

pressing the

buttons in an 8 s period

 

can be repeated and the command is

performed.

b. The option „

Do not set with active zone“, 

doesn´t  allow the

system to be set using a remote control (key  fob) when any

zone with an 

Instant

  reaction is active. To set the system all

zones have to be in standby.

Take over a user´s access privileges:

 Taking over a user´s access 

privileges for the sections and time limited access according to the 

specific user, it respects individual access to the controlled section and 

also limited access to a section if pre-set. Factory settings: disabled. 

Take over a user´s identity:

  The selected user will be visible as 

a source in the event log. Factory settings: disabled. 

Delayed panic:

 Valid for reactions such as Silent panic and Audible 

panic. The delay can be set from 5 to 240 s. Cancelling the panic alarm 

during  a  running delay can be performed by repeated pressing of the 

specific button. 

Operation with a multipurpose relay (MPR) 

The remote control can also be enrolled to a multipurpose relay of the 

AC-16x series, to control a relay according to the chosen mode. Each 

button should be enrolled to the MPR with a different mode. Even one 

remote can be enrolled to multiple MPRs for example with a different 

function. When you enroll a keyfob to the control panel and also to an 

MPR within its RF range, don´t select the same buttons. To enroll 

a keyfob to an MPR, follow the installation manual of the MPR. 

The control panel is able to run a maximum 

of 5 simultaneous timers (delayed panic 

alarms). 