background image

JABLOTRON

ALARMS

a.s.

Pod

Skalkou

4567/33

46601

Jablonec

n.

Nisou

Czech

Republic

www

.jablotron.com

||

|

The JA-162A Internal wireless siren 

The JA-162A Internal wireless siren 

1 / 2 

MNJ51103 

1

The JA-162A is a component of the 

JABLOTRON 100 

system.  

It is used for alarm indication inside a building. It can also be used 
for other acoustic indications (PG outputs, entry/exit delays and 
doorbell). Pressing the siren button can silence the alarm 

 

(= confirmation of a person’s presence in the building) or trigger  
a panic alarm (optional function). The siren is equipped with  
a backup battery for cases when AC dropouts can happen. It has 
also got a built-in detector of siren tampering by disconnection from 
its electrical socket. The siren should be installed by a trained 
technician with a valid manufacturer’s certificate. 

 

 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 

Figure 1: 1 – transparent control button 

Installation and enrolling the siren to the 

control panel 

It is necessary to perform the enrollment procedure in service mode 

and the system has to be equipped with an JA-110R radio module.  

1.  Plug the siren into the required electrical socket where there is 

still a good RF range to the control panel. 

2.  The  control  button  (1)  lights  permanently  with  a  yellow  colour 

and  it  means  the  siren  is  ready  to  be  enrolled.  If  the  control 
button  (1)  doesn´t  light  permanently,  then  follow  the 

Warning

 

below.  

3.  Go  to  the  F-link  software,  select  the  required  position  in  the 

Devices  window  and  click  on  the  Enroll  option  –  enrollment 
mode is then launched.  

4.  Press  the  control  button  (1)  on  the  siren.  The  siren  is  thus 

enrolled to required position and the yellow LED goes off.  

5.  Set the siren properties (see the Internal setting chapter)  

Warning

: If the battery is low then the siren can´t be enrolled to 

the control panel. This status is indicated by the periodical flashing 
of the yellow LED each 15 s. It is strictly necessary to wait (usually 
a few minutes) until the backup battery is charged to the point when 
it is able to transmit the enrolling signal. When the backup battery is 
fully charged (permanently lit yellow LED), open the enrollment 
mode and then press the control button (1) to transmit an enrolling 
signal.  

If the siren is unplugged from the electricity then it will be able to 

work for 12 hrs from the backup battery. When the backup battery 
voltage reaches the critical level, then the siren is turned off to 
protect the backup battery against damage. 

Internal settings of the siren 

Go  to  the 

Devices 

tab  in  the  F-Link  software.  When  you  are  at 

the siren position, use the 

Internal settings

 option to open a dialog 

window where you can set: (* indicates default settings). 

Sections: 

defines  for  which  sections  the  siren  should  indicate  an 

alarm and possibly also entrance / exit delays and system setting. The 
default setting is indication disabled for all sections.* 

Reaction: defines whether the siren should indicate an 

IW*

 

(internal warning) or 

EW

 (external warning) signal. Alarm indication with 

siren  chirps  can  also  be  completely  disabled  (other  functions  remain 
active). 

Siren tones: 

intermittent

*, 

continuous

 

Maximum siren time: 

1, 2, 3*, 4, 5

 

minutes.

  

Detection of tampering

:

  by  the  built-in  accelerometer  the  siren 

detects  its  disconnection  from  electrical  socket.  Options 

Disabled, 

Always*, During alarm. 

Higher  volume:  YES  /  NO*  - 

affects  only  entrance/exit  delay 

signalling and sounds indicating PG output triggering. 

Beeps during section control: 

YES  /  NO* 

-  if  enabled,  the  siren 

chirps  once  after  setting,  twice  after  unsetting  and  three  times  when 
unsetting after an alarm. It only does so for selected sections. 

Entrance delay beeping: 

YES  /  NO*

    if  enabled,  it  indicates  the 

entrance delays of the selected sections. 

Entrance delay beeping with a partially set system: YES

 / NO*

  if 

enabled,  it  indicates  the  exit  delays  of  the  selected  sections  when 
partially set. 

Exit delay beeping: 

YES  /  NO*

 

 

if  enabled,  it  indicates  the  exit 

delays of the selected sections. 

Flash when button is pressed: YES

 / NO*

 

 

if enabled, it indicates 

pressing the button by quick flash of the LED.  

Acoustic signalling of PG output activity: 

Sound indication can be set for each PG output:

 

No

  

-  PG output generates no sound 

Slow beeping

  

-  slow chirping – 1 per second (for the whole period 

when the PG is active) 

Quick beeping

     rapid chirping – 2 per second (for the whole period 

when the PG is active) 

One beep

  

-  1  chirp  when  the  PG is  activated, 2  chirps  when 

the PG is deactivated 

20 sec of beeping

   20 sec long chirp when the PG is activated 

Melodies 1,2,3,4

   -  doorbell melody selection 

Control panel reaction to pressing the siren button: 

The default setting is that pressing the siren button (1) during an 

alarm  mutes  the  siren  and  concurrently  confirms  a  person’s 
presence in the building (a report is sent).  

It is possible to change the siren button reaction in order to function 

as  a  panic  alarm  button  (1)  in  the  Devices  window  in  the  F-Link 
software. In such a case the system responds to the pressing with a 
panic alarm in the section to which the siren has been assigned. 

Test 

 

by pressing the TEST button you can test the siren function 

and the siren reacts to this pressing by 3 s alarm sound. 

 

Note: 

The siren sound has the highest priority, the chirps during control 

have a lower priority and the PG output activity indication has the 
lowest priority (PG1 has a higher priority than PG2 etc). The chirp 
with higher priority always terminates the chirp with a lower priority. 

 

To  set  the  siren  to  comply  with  security  grade  2 
according  to  the  EN50131  norm,  use  F-Link  SW  (1.4.0 
and higher), the Parameters tab and the option System 
profiles.

 

Backup battery replacement 

The  siren  checks  the  backup  battery  status  automatically.  The 

current  status  can  be  checked  by  the  F-link  software  tab  called 
Diagnostics  (current  battery  status,  its  voltage  when  loaded  and 
unloaded).  When  a  backup  battery  fault  is  triggered,  then  it  is 
necessary  to  replace  it  as  fast  as  possible  to  avoid  siren 
malfunctioning.  

The  control  panel  must  be  in  service  mode  (see  control  panel 

installation  manual)  then  it  is  possible  to  open  the  siren  cover,

 

before  you  start  changing  the  battery.

  Valid  when  Detection  of 

tampering  is  enabled.  Always  use  a  3,6  V,  170  mAh  (BAT-3V6-
N170) backup battery.  

Note

: If the battery is low (as reported to the control panel) the 

siren is not able to fully perform all its functions  

 
   

Battery replacement procedure: 

 

Battery replacement can only be done by a 
person  with  an  adequate  electrotechnical 
qualification  and  only  when  the  siren  is 
disconnected from its electrical socket. 

1.  Unplug the siren from the electrical socket. 
2.  Unscrew the 4 locking screws on the siren’s rearside and remove 

the rearside carefuly. 

3.  Take out the PCB from the Front part. 
4.  Now  it  is  possible  to  replace  the old  backup battery.  Fix  the  new 

backup battery by the ties and connect it by connector to the PCB.  

5.  Re-assemble the siren in reverse order of the points (1 – 3) – be 

careful,  the  spring  has  to  be  correctly  assembled  on  the  LED’s 
body otherwise the button will not work (1). 

 

Reviews: