JA-63 „PROFI“  

Alarm system - installation manual 

 

 

 

 

 

 

 

Summary of Contents for JA-63 PROFI"

Page 1: ...JA 63 PROFI Alarm system installation manual...

Page 2: ......

Page 3: ...ication 12 9 19 Arming and disarming chirps with wired siren 12 9 20 Siren alarm in Disarm Partial arming 12 9 21 Wireless siren alarm 12 9 22 Indication of system problems when arming 12 9 23 Control...

Page 4: ...ssages calls to predefined telephone numbers and plays audible warning communicates with 2 CMS allows remote access from a phone s keypad and can be set via web page Operation and programming is possi...

Page 5: ...nd used to hang it from the wall Its active part from the plastic ring to the coil should be installed vertically and should not be obstructed by any large metal object The antenna can be located behi...

Page 6: ...e setting in the programming mode see 9 6 The control panel also wirelessly transmits the PGX and PGY signals and UC receiving units can be used as remote outputs for these signals U is a back up powe...

Page 7: ...ess item manual when installing After you install the item to the desired location leave it un powered and without its cover The method of enrollment is described in section 9 1 7 Back up battery inst...

Page 8: ...YES 310 NO YES Siren alarm enabled 32x 321 YES 320 NO YES Exit delay audible indication enabled 33x 331 YES 330 NO YES Partial arming exit delay audible indication 34x 341 YES 340 NO NO Entrance dela...

Page 9: ...ill enroll to position A when its power is switched on If you need to enroll a siren which is already powered and it is not possible to easily switch off its power you can enroll it the following way...

Page 10: ...ed message and phone number editing in the user mode sequence 2 5 x The User mode which is accessible with F 0 Master Code is for bypass setting system testing and battery replacement This setting ena...

Page 11: ...etter understanding you can simply imagine that the master control panel is just another remote control Arming control of the subsystem by the master control panel can be disabled by erasing the corre...

Page 12: ...setting has no effect options 3 7 1 alarm in disarm partial arming enabled 3 7 0 alarm in disarm partial arming disabled Factory default setting enabled 9 21 Wireless siren alarm sequence 3 8 x The w...

Page 13: ...e triggered or a fault indication will be generated when communication with the detectors is lost and the control panel is armed Options 6 9 6 1 Communication loss causes an alarm 6 9 6 0 Communicatio...

Page 14: ...completed Time Setting 4 hh mm dd MM YY where hh hours 24 hr cycle mm minutes dd day MM month YY year Example on Jun 30 2007 at 17 15 enter 4 17 15 30 06 07 After the control panel is powered its inte...

Page 15: ...C 60A interface cable Comlink software is designed for the Windows system User can check and operate the JA 63 system easily via their PC can read complete events memory with all details can view the...

Page 16: ...change location of the detector or use an optional sensor s lens fault or alarm C is indicated blown fuse in the control panel or radio communication jamming PC with Comlink SW gives details when acti...

Page 17: ...uts Alarm relay dry contacts 1A 60V programmable outputs PgX PgY Chime Fire Arm Panic Alarm Door Home AC failure siren output 12 V 0 7 A Wireless outputs control panel transmits signals for siren and...