JA-88P outdoor wireless motion detector
1 / 2
MKU52105
JA-88P outdoor wireless motion detector
The JA-88P wireless PIR detector is designed to indicate movement outside
the building caused by human bodies. It is based on an outdoor detector by
Optex supplemented with a transmitter compatible with JA-80 OASiS
systems. Both the detector and the transmitter are powered by three lithium
batteries and the low battery signal is transmitted to an control panel. The
detector is equipped with two TAMPER contacts (front and rear), which
immediately report opening of the detector cover or its possible tearing from
the place of installation. The detector regularly performs automatic tests and
reports its status to the control panel.
Installation
The following instructions should be followed when selecting a place for
detector installation:
The detector must be installed in a position where its bottom surface is
parallel to the watched zone (either directly on the wall, or possibly, if a
change of direction is required, the supplied joint can be used). This
condition is essential for good immunity to false alarms. For more
information see Fig.1.
The detector should be installed 2.5 – 3 m above the ground.
No other moving objects (bushes, trees, high grass, etc.) should be situated in
the detection area of the detector. These objects can be masked out using the
supplied foils. Avoid direct action by strong sources of light (sun reflections).
You can use the supplied viewing hood for this purpose.
When selecting the right place to install your detector, keep in mind that the best
movement detection is provided when the detection zones intersect (Fig.2).
PARALEL
2,5 ... 3m
TILT
Fig.1 and 2
1.
Unfasten the curing screw on the bottom side of the upper cover and
remove it.
2.
Pull the plastic tab under the lower PIR sensor slightly to remove the
optical part.
Warning: Do not touch the detector sensing face during
handling.
3.
Use a screwdriver to punch a hole on the right of the bottom detector
cover in order to pull the rear TAMPER cable through (supplied in the
package).
When installed without the joint holder:
Use the
Base Mounting Template
from the box lid
.
Pull the rear TAMPER cable through the punched hole in the bottom
detector cover and fix a magnetic contact to the place according to the
template
(Base side)
.
Mark a place on the wall where you want to install the detector – i.e.
holes for the screws and the magnet (
Wall side), and
fix the magnet
to the wall.
Fix the rear cover on the wall while checking the position of the
magnet and the reed contact (they should be as close as possible).
When installed with the joint holder:
Use the
Bracket Base Mounting Template
from the box lid
.
Press the plastic tab to remove the screw cover (secured with a
plastic cord against falling during work ).
Unscrew the securing screw (inside under the cover) to loosen the
joint and swivel it to one side to gain access to the installation
holes.
Pull the rear TAMPER cable through the cavity in the joint and fix
the magnetic contact in the given place (between the plastic lugs).
Mark a place on the wall where you want to install the detector – i.e.
holes for the screws and the magnet
(Wall side),
and
fix the magnet
to the wall.
Fix the joint holder to the wall while checking the position of the
magnet and the reed contact (they must touch).
Now screw the bottom cover together with the joint holder. Remove
the central screw which blocks vertical movement and screw it
through a hole in the bottom cover.
4.
Pull the rear TAMPER cable through the opening you have punched
in the bottom detector cover and insert the rear TAMPER connector
into the pins marked TMP IN (remove the jumper installed in
production).
Enrolling the detector to the system
The signal transmitter for wireless communication is located underneath
the optical part of the detector.
The transmitter’s battery case is not
used;
the batteries are inserted into the battery holder of the motion
detector.
Use three AA 3.6 V lithium batteries by the same
manufacturer and replace all three batteries at the same time.
The
correct position of the batteries is indicated on the battery holder. When
inserting the batteries, it is necessary to remove the part of the holder held
in place with a metal lug. When the batteries have been installed, the
transmitter sends a signal which enrolls it to the control panel (the control
panel must be in enrollment mode at that time – see the manual). Use
switch no. 2 to set the system’s reaction to any detected movement (ON =
instant or OFF = delayed). Switch no. 1 should be left in the OFF position
rear tamper
connector
Switch 1
INSTANT
DELAY
Switch 2
PULSE*
STATUS
Vcc
TMP
INP
GND
interconnection
to a detector
indication
Set pulse mode
*
battery not
used
Fig. 3 detector transmitter
BRACKET BASE
BRACKET
SHAFT COVER
BASE
BATTERY HOLDER
OPTICAL PART
PIR SENSOR
(
)
DO NOT TOUCH
IR ANTIMASKING
INSTALATION SCREWS
JOINT POSITION LOCKING
(DETECTOR TILT)
LED INDICATOR
MASKING FOIL
LENS
UPPER COVER
SECURING SCREW
PROTECTIVE HOOD
COVER SCREWS
JOINT POSITION LOCKING
(DETECTOR DIRECTION)
Fig.4 detector configuration