background image

Model 37010-Series

ELECTRIC MARINE TOILET 
Push Button Operation

FEATURES

• White Vitreous China Bowl Available in Two Sizes

• Baked Enamel Seat & Cover in Compact or

Household Size

• Flexible Impeller Flush Pump

• Permanent Magnet Type Motor, Fully Enclosed, with

Stainless Steel Shaft

• High Capacity Macerator and Bowl Scavenger Pump

• Built-in Back Flow Preventer

• All Corrosion Resistant Material for Marine Use

VARIATIONS 

VOLTAGE

COMPACT SIZE

HOUSEHOLD SIZE

12 Vdc

37010-0000

37010-1000

12 Vdc EMC

37010-0090

37010-1090

24 Vdc

37010-0006

37010-1006

24 Vdc EMC

37010-0096

37010-1096

32 Vdc

37010-0003

37010-1003

INSTALLATION

The Jabsco electric toilet may be installed above or below
the waterline. Flush pump is self-priming with a vertical lift
up to 4 feet; discharge macerator pump can operate
against a vertical head up to 4 feet.

Inlet and outlet seacocks should be easily accessible and
be positive shut off valves. If seacocks cannot be conve-
niently operated from toilet location, install suitable shut off
valves for inlet and discharge connections.

Base assembly may be moved 90° to accommodate con-
nections and provide accessibility for servicing.

Surface where toilet is mounted should be flat to prevent
distortion of toilet base.

PLUMBING CONNECTIONS - Connect inlet hose using
either 5/8" or 3/4" ID hose (a sleeve is included to adapt
pump inlet from 5/8" to 3/4"). Make sure all inlet connec-
tions are airtight and free of sharp bends or restrictions.

Connect 1" or 1-1/2" hose to discharge port (Adaptor
98023-0080 is included to convert discharge port to 1-1/2"
ID hose), and make suitable connection to holding tank or
other discharge system. Avoid sharp bends or restrictions.

For above waterline installations, a check valve may have
to be installed in the flush water intake line to ensure rapid

Model 37010-Series

pump priming. To retain water in bowl, make a loop in the
discharge line about 8 inches above base of bowl.

Do not connect the toilet to the vessels

potable water for its source of supply. To do so can result in
contamination of potable water supply. If fresh water is pre-
ferred for flushing, provide a separate fresh water tank to
supply water to the toilet only.

DO NOT CONNECT INLET HOSE TO A PRESSURIZED
WATER SYSTEM.

If the toilet is, or can be, below waterline at any normal
(including static) attitude of vessel heel and/or trim, a 3/4"
Vented Loop Fitting must be installed in the length of hose
connecting the flushing pump to the inlet seacock. The
Vented Loop Fitting must be positioned so it remains slight-
ly* above the waterline at all angles of heel and trim.

In some installations when a vented loop is installed in the
intake hose, the flushing pump primeability and flow char-
acteristics are reduced and may adversely affect toilet
function. To restore pump performance, connect a solenoid
valve (Jabsco No. 37068-0000) to the vent air inlet to inter-
rupt the air supply during the flush cycle. The brass port of
the solenoid valve (remove plastic filter if attached) should
be connected to the vent inlet with 3/16" hose and the
solenoid wired in parallel with the toilet motor. See
Diagram 1 for installation and wiring illustration.

* Recommended minimum height above waterline is 6".

CAUTION

!

Flood hazard.   If toilet is installed below the 
waterline or may be below the waterline at any 
angle of heel or trim, it must be installed with 
properly positioned vented loops.  Failure to do 
so can result in flooding which can cause loss 
of property and life.

WARNING

!

Reviews: