JACUZZI COMET CLEANER
//
Troubleshooting Guide
Symptom
Possible Reason
Corrective Action
Power Supply
The power supply is not
working/responding to pushing buttons
1.
Control panel is damaged
2.
Power switch & PCB are
damaged
3.
Power supply is unplugged
1.
Replace control panel
2.
Replace power switch & PCB
3.
Check to ensure power supply
cord is plugged in
LED Indicators
All three LED indicators on power
supply are flashing
The cleaner has finished current cycle
Power off the cleaner
Only one LED indicator on the power
supply is flashing
The cleaner is running automatically
No action required
LED indicators are not flashing/not
working even after selecting cycle
setting
Control panel is damaged
Replace control panel
Movement
Cleaner is floating on the surface of the
water, not sinking to/staying on pool
floor
Cleaner was deployed without exhausting
the air inside it completely
Deploy the cleaner only after exhausting
the air inside it completely
Cleaner will only travel halfway across
pool, then stops completely
1.
Nozzle is on backwards, causing
friction between impeller and
water channel, which warns
cleaner to stop
2.
Power unit has failed
3.
Motor has failed
4.
Cable is broken
1.
Reinstall nozzle
2.
Replace power switch & PCB
3.
Replace motor
4.
Replace cable
Cleaner stops/gets stuck at walls/stairs Toothed clutch between impeller and
axle sleeve is engaged improperly
Replace impeller and axle sleeve
Cleaner does not move at all
1.
Power unit has failed
2.
Motor has failed
3.
Cable is broken
1.
Replace power switch & PCB
2.
Replace motor
3.
Replace cable
Cleaner is moving in circles
Improper nozzle angle is set
Adjust nozzle angle
Cable has excessive tangling
Improper nozzle angle is set