Anti explosive type lumina res
i
980820200_09_004
Page 1 from 3
IP-66
CONFORMITY WITH STANDARDS EN 60598-2-22 - UNE
20392.93 - UNE 20062.93 - EN 50014 EN50018
CONFORMITY TO DIRECTIVE 94/9/CE (ATEX)
ο
CERTIFICATE N 02ATEX2041 X
CE 0163
e
x
II2GD
o
o
EExd IIC T6 T85 C Y EExd IIC T6 T85 C
D
L
156
115
196.5
DIMENSIONS
TYPE
L
D
FSA-8202C
FSA-8352C
FSA-2118C
FSP-3236CC
IFA-3136P
IFA-3236
IFA-3236P
IFA-4258P
485mm
485mm
750mm
1350mm
1350mm
1350mm
1350mm
1650mm
391mm
391mm
656mm
1256mm
1256mm
1256mm
1256mm
1556mm
MOUNTING & CONNECTING
FIG. A
1
2
FIG. D
5
3
FIG. B
FIG. C
REMOTE
CONTROL
DEVICE
230 V – 50 Hz
4
1. Unscrew the hexagonal screw with 2 mm Allen key (Fig. A).
2. Turn the cover until completely being taken off (Fig. A).
3. Extract the connecting plates (Fig. B).
4. Connect the wires to the mains supply (Fig. C). The main supply
connection are indicated on the label next to the connecting plate. The
connections must be done with the mains supply cables out of tension.
The mains supply cables must be introduced into the housing through
the metallic stuffing box due to ATEX directive and certified by an
organism, adapted to used cables (threads: ¾ NPT).
5. Insert again the connecting plates into their right place (Fig. D).
6. Put the cover in its place and turn it until being completely closed (fig E).
7. Screw the hexagonal screw with the 2 mm Allen key (Fig. E). Maximum
tightens force: 0.85 N*m (±15%)
8. Mount the ceiling-bracket. The ceiling-bracket are mounted in the
housing with screws M8x15 + ø16/8.5 flat washer + ø14/8.5 fluted
washer (Fig. F).
9 .Fix luminaire in ceiling or wall, screwing in the holes located in the
ceiling-bracket (Fig. F).
10. Mains supply: ~230 V 50 Hz .
6
7
FIG. E
8
9
9
FIG. F
FSA-8203C
485mm
391mm