background image

WWW.JADERANGE.COM

CHINESE RANGE

T

IT

A

N

 C

H

IN

E

S

E

 R

A

N

G

E

MODEL NO.

DESCRIPTION

o

jcr-1

one hole chinese range

o

jcr-2

two hole chinese range

o

jcr-3

three hole chinese range

o

jcr-4

four hole chinese range

o

jcr-5

five hole chinese range

o

jcr-6

six hole chinese range

STANDARD FEATURES

• Heavy gauge stainless steel front, sides, interior angle

structuring, plate shelf, top, sides & pipe legs

• Range top 12 gauge stainless steel angle iron and reinforced

with 10 gauge steel burner chamber

• Heavy gauge steel body structure
• Each burner individually controlled—each hole has individual

main “shut-off” valve

• Heavy-duty stainless steel pipe legs with adjustable feet for

leveling

• Stainless steel tubular rack provided for holding wok covers
• Top-cooling water flow is controlled by independent valve—

water flows through perforated stainless steel tube running
the length of the appliance, beneath 14 gauge stainless steel
front plate shelf

• Gas inlet and water drain location are available (by

specification) at either end on rear of appliance

• Appropriate size wok, cover and drip pan for each hole
• Stainless steel drip pan for each hole
• One faucet kit for every two holes
• Spice tray
• 1-1/4" gas regulator

form #jt0550 ©2008 jade range, llc

JCR-4 (four 20

"

holes)

TM

®

TITAN

DRAIN PIPE 2" 

(SPECIFY LEFT OR RIGHT)

1 1/4" GAS

DRIP PANS

1/2" WATER

CONN.

40" [1016]

10 1/2" [267]

20" [508]

30 1/2" [775]

62 3/4" [1594]

1 1/2" [38]

10" [254]

2" [51]

2 1/2" [64]

16" [406]

14 3/4" [375]

4 1/2" [114]

30" [762]

3" [76]

24" [610]

LENGTH

CONNECTION

(SPECIFY LEFT OR RIGHT)

CUSTOM CHINESE RANGE FORMULA

To calculate width of range, add 1" to each hole plus width of hole; add
4" for each side; add 6" between each hole.

Example: For JCR-2 (one 14" hole and one 16" hole), calculate
4 + (14 + 1) + 6 + (16 + 1) + 4 = 46" overall width

PLEASE SPECIFY WHEN ORDERING

• Hole Size(s)
• 3-ring 

o

or Jet Burners 

o

• Gas Inlet: Right 

o

Left 

o

• Water Drain:   Right 

o

Left 

o

• Manual 

or Swing on Faucet 

o

Ring burners or jet burners to 100,000 BTU/hr. each

H

H

Standard hole diameters are: 12", 14", 16", 18", 20", 22" & 24". 
Depth is 42" when 24" hole is specified.

JADE RANGE, LLC., A MIDDLEBY COMPANY • 2650 Orbiter Street • Brea, CA 92821 •  PHONE:  800-884-5233   FAX:  714-961-2550

Note: In line with their policy to continually improve products, Jade reserves the right to change materials and specifications without notice.

printed in usa