background image

H0342700 

Rev A

AquaPure

®

 Ei

TM

 Series 

Replacement Kits 

for Models APURE35/35C

These instructions are to be used with the following Jandy

 

Replacement Parts:

R0512100 -- R-Kit, Power PCB Assembly

R0512300 -- R-Kit, Control PCB Assembly

R0512400 -- R-Kit, Controller Cover Assembly

R0512500 -- R-Kit, Output Cable Assembly

1. Introduction

 

This document gives instructions for replacing 

various components on the Jandy AquaPure Ei chlorine 

generating device. 

 

The instructions were written with safety as the 

priority and must be followed exactly. Not following the 

written procedure or taking shortcuts may increase the 

risk of personal injury. Read through the instructions 

completely before starting the procedure. 

 

Before starting the procedure, use the parts list at 

the back of these instructions to identify the parts that 

are in your kit. If any parts are missing from the kit 

please call your local Jandy distributor for assistance. 

For technical assistance, please contact our Technical 

Support Department at 1.800.822.7933.

2. Ordering Information

 

To order or purchase parts for the Jandy AquaPure 

Ei chlorine generating device, contact your nearest 

Jandy dealer or distributor. If they cannot supply you 

with what you need, call Zodiac Pool Systems, Inc. at 

1.800.822.7933.  In Canada call Zodiac Pool Systems 

Canada, Inc. Customer Support Department at  

1.888.647.4004. 

WARNING

FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed 

and qualified in pool equipment by the jurisdiction in which the product will be installed where 

such state or local requirements exists. In the event no such state or local requirement exists, 

the installer or maintainer must be a professional with sufficient experience in pool equipment 

installation and maintenance so that all of the instructions in this manual can be followed 

exactly. Before installing this product, read and follow all warning notices and instructions that 

accompany this product. Failure to follow warning notices and instructions may result in property 

damage, personal injury, or death. Improper installation and/or operation will void the warranty.
Improper installation and/or operation can create unwanted electrical hazard which can cause 

serious injury, property damage, or death. 

Summary of Contents for AquaPure Ei Series

Page 1: ...tion To order or purchase parts for the Jandy AquaPure Ei chlorine generating device contact your nearest Jandy dealer or distributor If they cannot supply you with what you need call Zodiac Pool Syst...

Page 2: ...s and lifting up see Figure 2 Figure 1 Power Pack R Kits Outpu t Flow On O ff Salt Power Pack Cover Assembly R0512400 Power PCB Assembly R512100 Control PCB Assembly R512300 Output Cable Assembly R512...

Page 3: ...able Assembly 1 Ensure that all power to the power pack and the controller is disconnected turned off at the circuit breaker 2 Remove the terminal cap from the cell and disconnect the cell leads 3 Det...

Page 4: ...safety and safety of equipment B Bonding 1 The National Electrical Code NEC requires pool equipment to be bonded to each other Check your local codes to determine if the NEC and or other local install...

Page 5: ...TVSS PCB Assembly to Green 4 pin connector see Figure 8 a Into Green 4 pin connector insert the Blue Wire into Pin 2 120v Or Neutral b Into Green 4 pin connector insert the Brown Wire into Pin 4 120v...

Page 6: ...and AquaLink RS Control System or PDA Network Cable Tie Comm Hole Figure 9 Accessing and Wiring to the Power PCB 7 In the AquaLinkRS or PDA power center wire the power pack directly to the LOAD SIDE o...

Page 7: ...power off to both devices and repeat steps 1 and 2 If the power pack still does not connect to the controller re check the wiring connections see Figure 10 and the controller setting on the power pac...

Page 8: ...K RS OR PDA BLK YEL RED GRN RED BLK BLK NOT USED LOAD 2 LOAD 1 GROUND CHASSIS WHT TO EARTH BONDING POINT NOT USED NOT USED NOT USED TRI Ei TVSS PCBA BLUE BRN Figure 12 240 VAC or 120 VAC Wiring Diagra...

Reviews: