Features 

UL217 Listed

Sleek design

Wall tamper

Strong, reliable RF signal

Low Battery indication 

Key Instructions

1. Read the “INSTALLING YOUR SMOKE ALARM” section

a. Install your Smoke Alarm.

2. Enroll the Smoke Alarm in a panel:

a. Place the JAQX Smart Hub into wireless enrollment mode by pressing the 

external red button for 3 seconds until hub beeps.

b. Send an enrollment signal from the sensor by press & holding TEST button 

until you hear the sounder beep.

3. Confirm that the sensor has been properly enrolled by checking for new FLOOD zone 

on your JAQX App or in your customer portal.T

4. Test the Smoke Alarm is enrolled in a panel:

a. Press & hold TEST button until you hear the sounder beep.

b. Panel will indicate a Smoke Test.

c. Read the “WEEKLY TESTING OF YOUR SMOKE ALARM” section:

5. Test the functionality of the Smoke Alarm.

 

Operation

 

Situation

 

Sounder

 

LED

 

Wireless Signal to Panel

Recovery

 

Actual smoke 

RED 

(pulsing) 

Wireless Smoke Alarm Signal 

sent to hub.

Silence an actual alarm with the TEST button.  Sensor will return to 

alarm if smoke is still present. 

Press & hold test 

button 

Wireless Smoke Test Signal 

sent to hub.

Sensor: Restore by releasing the  test button

Removing Sensor 

from Mount

Tamper/Trouble signal to be 

sent to hub. 

 Restore by remounting. 

Low Battery   

Chirp 

Yellow/Red

(blink) 

Maintenance Needed 

Temporal 3 

(Loud) 

Yellow

(Pulsing) 

Supervisories Not Sent

Replace Unit 

Specifications 

Approval: 

UL217 Single Station Smoke Alarm & Heat Alarm 

Smoke Sensitivity: 

1.31 

– 

2.28 %/ft 

Heat Temperature: 

135 to 140 F 

Smoke Technology: 

Photoelectric

 

aHeat Alarm Point:  135 

– 

149 F  (UL

 

Alarm Sound:  

Temporal Three 

Replacement Battery: 

Panasonic CR123A 
Duracell DL123A 

Temperature Range: 

32 to 120 F (Long Term) 

Humidity: 

10 

– 

85% Relative Humidity 

Housing dimensions: 

4.7 inch diameter, 2.1 inch high 

Frequency: 

433.92 MHz 

System Compatibility: 

RE6100 series panels with capacity of up to 96 zones 

User's Manual: 

47-0001-08 Rev A 

Design & Manufacture: 

Resolution Products, Inc. 
1402 Heggen Street 
Hudson, WI 54016

 

Smoke Sensor

Temporal 3 

(Loud) 

Yellow

(Steady) 

Temporal 3 

(Loud) 

Temporal 3 

(Loud) 

RED 

(pulsing) 