background image

Jason International, Inc.  •  

 

501.771.4477  

    

Page 1 of 16

    

Customer Service :  800.255.5766 

Copyright © 2014 Jason International.

Owner’s Manual

Home spa

InsTallaTIOn, OPeraTIOn, anD MaInTenanCe

49-1014-301

Date   05/2014

“TO Be reMOVeD FOr use BY THe OCCuPanT”

Jason International, Inc.

 

8328 MacArthur Drive

North Little Rock, AR 72118
www.jasoninternational.com

Owner’s reCOrD

Dealer: 

Date Purchased: 

Date Installed: 

Installer: 

PlaCe serIal nuMBer CarD wITH 

PrODuCT COnFIguraTIOn In THIs BOx

InsPeCTIOn

Inspect the unit prior to installation. In the event of a 

problem, DO NOT install the unit.

  

All components are factory assembled to the bath and the 
unit is water tested and inspected prior to leaving Jason 
International, Inc.

If the carton shows sign of damage, inspect the product 
before accepting and describe the problem on the Bill of 
Lading.

NOTe: Transportation and insurance from Jason’s 

factory are the buyer’s responsibility.

Damage sustained in transit is the responsibility of the 

carrier.

 If damage is discovered, 

The carrier must be immediately notified in writing with a 
request for a representative to inspect the unit. Failure of 
the carrier to respond should be reported to the seller and 
carrier. Always file a freight claim promptly.

The installer is responsible for insuring that the unit is 
free from defects or shipping damage. In the event of a 
problem, DO NOT install the unit. 
Jason International is not responsible for damage that 
might have been avoided by inspection or testing prior to 
installation.

If the carton shows sign of damage, inspect 

the product before accepting and describe the 

problem on the Bill of lading.

Damage to the unit during installation will not be covered 
by warranty and is the responsibility of the installer. ALL 
WARRANTY CLAIMS ON ACRYLIC SURFACE DAMAGE 
MUST BE MADE PRIOR TO INSTALLATION. Inspect 
plumbing and bath surface for missing or damaged 
components. Alert your dealer of any discrepancies.
To protect the unit from damage keep the bath in the 
carton until ready for installation.

eQuIPMenT aCCess

In accordance with Building Codes, service access to all 
therapy bath equipment, controls, and electrical connections 
must be provided during installation (See 

Table 1 - 

Specifications

 for minimum access size).  Access must be 

provided for both the pump/control and the blower/control.  
Insufficient access will hinder repair and maintenance.  
Warranty service will not cover cost of providing equipment 
access.

78 x 78 x 28

90/170

36 x 17 in 

70.9

198 x 198 x 71

341/643

91 x 43 cm

346

78 x 66 x 28

80/160

36 x 17 in 

64.6

198 x 168 x 71

303/606

91 x 43 cm

315

Min. Size 

Access

Floor 

Loading

L x W x H (in.)                       

L x W x H (cm)

Gallons  

Liters

lbs/ft2     

kg/M2

HSC650 (Round)

1

1.5

HomeSpa COLLECTION (Air Whirpool Bath)

Model

Overall Dimensions

Operating 

Capacity

Blower  Pump 

HSR6555

1

1.5

HP

HP

W x H (in.)           

W x H  (cm)

Table 1 - Specifications

Summary of Contents for HSC650

Page 1: ...ge In the event of a problem DO NOT install the unit Jason International is not responsible for damage that might have been avoided by inspection or testing prior to installation If the carton shows s...

Page 2: ...ructions herein SeeUSERMAINTENANCEINSTRUCTIONSsectionofthis owner smanualforhumidityandmoldpreventionsuggestions prior to Installation 1 TheHomeSpabathisequippedwithseparatebathpumps and blower suppor...

Page 3: ...1 1 4 OVERLOAD PROTECTOR 1 5A TIME DELAY FUSE 1 4 x 1 1 4 TO MEDIA DEVICE REAR LEFT TO MEDIA DEVICE FRONT LEFT TO MEDIA DEVICE REAR RIGHT TO MEDIA DEVICE FRONT RIGHT NOTE THE NEGATIVE TERMINAL IS IDEN...

Page 4: ...g If the unit leaks with the unions hand tight then loosen the union s and check the O ring seal to ensure it is properly seated INSTALLATION INSTRUCTIONS cont 12 The acrylic surface of this bath has...

Page 5: ...w piping to the elbow of the existing piping INSTALLATION INSTRUCTIONS cont ELECTRICAL Electrical Power Supply These instructions are written assuming 60Hz 120V power supply Special notations are also...

Page 6: ...d that is temporarily secured to the packing board for shipping These boxes must remain on the control box bracket so that the two boxes can communicate properly through their infared communication fe...

Page 7: ...igure 4 Home Spa Control box connections C Eight pin mini DIN terminal for the Home Spa U1 keypad D Six pin mini DIN terminal for LED light E Six pin mini DIN terminal for installation of the water se...

Page 8: ...Refer to the Instruction Manual provided with the remote control for detailed instructions Automatic Purge Twenty 20 minutes after the control has shut off the blower will start again for a two minute...

Page 9: ...on on the Air Whirlpool bath These pumps are of efficient design incorporating high quality long life seals which provide superior service However should the pump need service suction and discharge un...

Page 10: ...r simply press and release to change the setting to Constant Wave Pulse or Off A 20 minute decreasing timer will be initiated when the blower motor starts Press and hold the Blower icon to cycle throu...

Page 11: ...mperature display from F Fahrenheit to C Celsius Product Test Diagnostics AfterselectingtheProductTestoptionfromthemenu theunit will perform a series of tests to confirm correct installation of compon...

Page 12: ...ur serial number proof of purchase and model number This will insure a quick response on warranty items The serial number can be foundonthefrontpageofthismanualoronthesmallcardadhered to the back of t...

Page 13: ...uit between bath and blower breaker box b Refer to installer dealer c Other items are connected to the same circuit c Refer to installer dealer Blower does not shut off a Defective keypad or timer a R...

Page 14: ...tion or discharge blocked a Remove obstruction b Suction air leak System usu ally surges b Make sure union is tight on suction side of the purmp Pump does not manually shutoff a Defective keypad or co...

Page 15: ...of alcohol anticoagulants stimulants antihistamines vasoconstrictors vasodilators hypnotics narcotics or tranquilizers F Persons with a medical history of heart disease low or high blood pressure cir...

Page 16: ...rnational Inc 501 771 4477 Page 16 of 16 Customer Service 800 255 5766 Copyright 2014 Jason International Jason International Inc 8328 MacArthur Drive North Little Rock Arkansas 72118 www jasoninterna...

Reviews: