Inverter Generator

 

OWNER

’S MANUAL 

 

 

 

 

JAVAC POWER TECHNOLOGY SA 

Please read and understand this manual 

completely before operating the machine. 

 

 

 

Summary of Contents for JVC3500iS

Page 1: ...JVC8000iS JVC5500iS JVC3500iS Inverter Generator OWNER S MANUAL JAVAC POWER TECHNOLOGY SA Please read and understand this manual completely before operating the machine ...

Page 2: ...r or use it with its parts removed Do not allow children to operate the generator Do not place any obstacles on the generator EXHAUST FUMES ARE POISONOUS Never operate the engine in a closed area or it may cause unconsciousness and death within a short time Operate the engine in a well ventilated area FUEL IS HIGHLY FLAMMABLE AND POISONOUS ...

Page 3: ...uel vapor or allow any to get in your eye s see your doctor immediately If any fuel spills on your skin or clothing immediately wash with soap and water and change your clothes When operating or transporting the machine be sure it is kept upright If it tilts fuel may leak from the carburetor or fuel tank ENGINE AND MUFFLER MAY BE HOT Place the machine in a place where pedestrians or children are n...

Page 4: ...t least 1 m from buildings or other equipment or the engine may overheat Do not operate the engine with a dust cover or other objects covering it When covering the generator be sure to do so only after the engine and muffler have completely cooled down ELECTRIC SHOCK PREVENTION Never operate the engine in rain or snow ...

Page 5: ... Never touch the machine with wet hands or electrical shock will occur Connect the ground lead of the machine to the ground earth terminal and connect the end to the ground electrode buried in the ground ...

Page 6: ...6 1 Fuel tank 2 Frame handle 3 Engine switch 4 Start switch 5 Display module 6 AC receptacle 7 Frame cover 8 Recoil starter 9 Fuel cock knob 10 Muffler ...

Page 7: ...r Hold the generator frame put the generator out of the box carefully placed on the ground Installed casters or foots Engine oil The generator has been shipped without engine oil Do not start the engine until you have filled it with the sufficient engine oil Remove the frame cover Remove the oil filler cap ...

Page 8: ...ngine oil SAE 15W 40 or higher Battery Remove the frame cover Connect the battery positive and negative pole line Fuel Fuel is highly flammable and poisonous Check carefully before filling Do not overfill the fuel tank otherwise it may overflow when the fuel warms up and expands After fill the fuel make sure the fuel tank cap is tightened securely Immediately wipe off spilled fuel ...

Page 9: ...uel cap Slowly add fuel to the tank DO NOT overfill Fill to the red level visible on the fuel filter Screw on the fuel cap and wipe away any spilled fuel Grounding Failure to properly ground the generator can result in electric shock Connect of a length of heavy gauge 12 AWG minimum copper wire between the generator ground terminal and a copper rod driven into the ground Generator location ...

Page 10: ...ecreational vehicle Deadly levels of carbon monoxide can build up in these areas Using a fan or opening windows and doors does NOT supply enough fresh air The generator must have at least five feet of clearance from combustible material Leave at least three feet of clearance on all sides of the generator to allow for adequate cooling maintenance and servicing STARTING ...

Page 11: ... Put the generator on a flat level surface Turn the fuel cock knob lever to the ON position Turn the engine switch to the ON position Press the start switch or pull the recoil starter to start the engine ...

Page 12: ...or a few minutes Press the AC button AC ON is green on the display module The generator has power output To prolong the life of the generator and attached devices allow the engine to stabilize and then add electrical loads one by one Never exceed the specified capacity when adding loads to the generator STOPPING Press the AC button AC OFF is red on the display module The ...

Page 13: ...wer output The engine speeds to idle for several minutes Turn the engine switch to the OFF position Turn the fuel cock knob lever to the OFF position MAINTENANCE AND STORAGE Engine Maintenance To prevent accidental starting ...

Page 14: ...ller cap Tilt the generator on its side and allow the oil to drain completely According to the models of capacity to add oil and replace oil filler cap Reinstall the frame cover Dispose of used oil at an approved waste management facility Spark Plugs Remove the frame cover Remove the plug cap from the spark plug Use the spark plug tool to remove ...

Page 15: ...g gap is 0 6 0 7mm Carefully thread the plug into the engine Use the spark plug tool to firmly install the plug Attach the spark plug cap to the plug Reinstall the frame cover Air Filter Remove the frame cover Remove the air filter cover Remove the foam element Wash in liquid detergent and water ...

Page 16: ...y dry in a clean cloth Saturate in clean engine oil Squeeze in a clean absorbent cloth to remove all excess oil Place the filter in the assembly Reattach the air filter cover Reinstall the frame cover Maintenance Schedule ...

Page 17: ...s or daily Clean around air intake and muffler First 20 hours Change oil Every 50 hours or every season Clean air filter Change oil if operating under heavy load or in hotenvironments Every 100 hours or every season Change oil Clean Adjust spark plug Check Adjust valve clearance Clean spark arrester Clean fuel tank and filter Every 3 years Replace fuel line ...

Page 18: ...DO NOT expose the unit to extreme conditions excessive dust dirt moisture or corrosive vapors DO NOT use a garden hose to clean the generator Storage The generator should be started at least once every 14 days and allowed to run for at least 20 minutes For longer term storage please follow these guidelines Generator Storage Allow the engine to cool completely before storage ...

Page 19: ...rom the fuel line and carburetor to prevent colloid build up Change the engine oil Remove the spark plug and pour about a tablespoon of oil into the cylinder Crank the engine slowly to distribute the oil and lubricate the cylinder Reattach the spark plug ...

Page 20: ... 7 Speed Regulating System Electric control speed regulation system Choke Type Electric control Starting Type Recoil E Start Generator Phase Type Single phase Voltage regulation Inverter Regulation Rated Frequency Hz 50 60 Rated Voltage V 110V 120V 220 240 Rated Output KVA 7 0 5 0 3 0 Fuel Capacity L 22 12 5 Max Output KVA 7 5 5 5 3 5 Dry Weight kg 76 74 42 5 L W H mm 715 545 560 610 478 465 Power...

Page 21: ...Place generator on a flat level surface Generator cannot supply enough power or overheating Generator is overloaded Review load and adjust Insufficient ventilation Check for air restriction Move to a well ventilated area No AC output Cable not properly connected Check all connections Connected device is defective Replace defective device Circuit breaker is open Reset circuit breaker Loose wiring I...