background image

2 Tools DDE Station 

with Pneumatic Pump

Ref. DDVE-QC

INSTRUCTION MANUAL

www.jbctools.com

Summary of Contents for DDVE-QC

Page 1: ...2 Tools DDE Station with Pneumatic Pump Ref DDVE QC INSTRUCTION MANUAL www jbctools com ...

Page 2: ...Metal Brush 1 unit Ref CL6217 Module Cable 1 unit Ref 0014874 DDE Control Unit 1 unit Ref DDE 1C 120V DDE 2C 230V DDE 9C 100V Brass Wool 1 unit Ref CL6210 Desoldering Iron 1 unit Ref DR560 A Stand 1 unit Ref DR SE Power cord 1 unit Ref 0010569 230V 0013671 100 120V General Purpose Handle 1 unit Ref T245 A ESD Tip Cleaner 1 unit Ref CL8499 Cartridge holder 1 unit Ref 0021083 2 ...

Page 3: ...f 0812620 Metal solder collector 1 unit Ref 0812630 Tip cleaning set 1 unit Ref 0965970 Long Tip Cleaning set 1 unit Ref 0965760 Suction Filter 1 unit Ref 0821830 Cotton Filter 1 unit Ref 0781046 It contains 10 filters Cleaning stick 1 unit Ref 0786640 Filter Box 1 unit Ref 0005966 It contains 50 filters Venturi Filter 1 unit Ref 0008446 Union Flanges 1 unit Ref 0011356 Manual 1 unit Ref 0023125 I...

Page 4: ...al Purpose Handle Ref T245 A Stand Cable Ref 0011283 Features Work simultaneously with up to 2 tools and join each station port with 1 module 1 pedal Peripherals RJ12 connector for Robot or Smart Fume Extractors USB B connector Equipotential connection Power Socket 4 ...

Page 5: ...ef 0014874 USB A connector 2 8 Color TFT screen Tilt the display for easy reading Pneumatic Desoldering Module Ref MVE A To another peripheral To Pedal Ref P 005 Air pressure 4 6 bar Tubing Ø4xØ6 mm Not supplied Main switch www jbctools com 5 ...

Page 6: ...arameters Default PIN 0105 Change port Displayed if temperature levels are activated Station Tools Counters Reset Language Peripherals Set the station parameters Set the tool parameters Consult modify the links of the peripherals connected to the station with the port they are connected to Display the hours worked in each cycle It is possible to choose the language from a list Allows you to carry ...

Page 7: ...Ceramic Chip components like MLCC this new and unique feature allows controlling the heating ramp up rate of the tool to gradually increase the temperature of the component through all the phases of the soldering process Up to 25 fully configurable soldering profiles can be stored USB flash drive is connected Station is controlled by a PC Station is controlled by a robot System notifications Stati...

Page 8: ...tc e g MV_a MV_b 3 Press Menu or Back to save changes MVE Initial Set up Pedal Initial Set up 1 Enter the Peripherals Menu and select the port which you want to join to the pedal 2 Select the pedal from the list Note that your first connection is denoted as a the second being b etc e g PD_a PD_b 3 Set the pedal function according to your work needs Select how the pedal acts as Sleep Extractor hibe...

Page 9: ... thanks to the Sleep and Hibernation modes which increase up to 5 times the life of the tip 3 Hibernation 1 Work 2 Sleep When the tool is lifted from the stand the tip will heat up to the selected temperature When the tool is in the stand the temperature falls to the preset Sleep temperature After longer periods of inactivity the power is cut off and the tool cools down to room temperature Long pe...

Page 10: ...proper connection Mark Desoldering process Use a tip with a larger diameter than the pad to achieve maximum aspiration and thermal efficiency 3 Aspirating 1 Placing 2 Rotating 4 Removing Place the tip over the lead If any solder remains are left on a terminal after desoldering it resolder it with fresh solder and repeat the desoldering operation When the solder melts gently move the tip in a circu...

Page 11: ...g the lid 3 Inserting the glass solder collector Check filter Lid Check internal joint 2 Cleaning Check the filter and replace it if it is dirty or damaged Remove the coil and clean the inside of the glass solder collector with the cleaning stick The lid must be unscrewed with the DR560 in a vertical position The glass solder collector must be inserted with coil filter in place positioned between ...

Page 12: ...bing Push the release ring to remove the pneumatic tubing Release ring 1 2 Spare filters Ref 0005966 Cotton filters Ref 0781046 Suction filter Ref 0821830 O Ring Ref 0007717 Filter cover Ref 0004710 Escape filter Ref 0008446 DR560 Maintenance The intake tube should be periodically cleaned with the largest rod possible Important DO NOT press the vacuum pump button while tinning the desoldering tip ...

Page 13: ...e brass wool ESD Tip Wiper Ref CL0240 A temperature resistant receptacle lets the operator remove excess solder by gentle tapping or wiping Antisplash Membrane Ref 0017574 Prevents splashing to maintain the work area clean Non slip base Sponge Ref S0354 No need to hold the base while cleaning tips The least harmful cleaning method Keep the sponge damp with distilled water when working to avoid tip...

Page 14: ...ge MSE A MVE A MNE A FSE A P 005 DDE C AD SE T210 A C210 T245 A C245 DN SE T210 NA C210 T245 NA C245 AP SE AP250 A C250 PA SE PA120 A C120 HT SE HT420 A C420 DS SE DS360 A C360 DR SE DR560 A C560 MVE A Compatibility Module Stand Tool Cartridge Range Control Units Peripherals DDE DME P 005 MVE A DS SE DS360 A C360 DR SE DR560 A C560 14 ...

Page 15: ...ed to clean the metal parts Periodically check that the metal parts of the tool and stand are clean so that the station can detect the tool status Maintain tip surface clean and tinned prior to storage in order to avoid tip oxidation Rusty and dirty surfaces reduce heat transfer to the solder joint Periodically check all cables and tubes Replace a blown fuse as follows Replace any defective or dam...

Page 16: ...can cause inflamable products to ignite Avoid flux coming into contact with skin or eyes to prevent irritation Be careful with the fumes produced when soldering Keep your workplace clean and tidy Wear appropriate protective glasses and gloves when working to avoid personal harm Utmost care must be taken with liquid tin waste which can cause burns This appliance can be used by children over the age...

Page 17: ...DE 烙铁头 O O O O O O 手柄 O O O O O O 电源线 O O O O O O 主机 O O O O O O 电源插座 O O O O O O 保险丝 O O O O O O 主开关 O O O O O O 电位连接 X O O O O O 变压器 O O O O O O 线路板 X O O O O O O 表示该有害物质在该部件所有均质材料中的含量均在GB T 26572 规定的限量要求以下 X 表示该有害物质至少在该部件的某一均质材料中的含量超出GB T 26572 规定的限量要求 www jbctools com 17 ...

Page 18: ...Notes 18 ...

Page 19: ...ient Operating Temperature 10 50 ºC 50 122 ºF Communicatio connectors USB A USB B Peripherals connectors Robot connector RJ12 for RS 232 protocol Control Unit Weight 3 815 kg 8 41 lb Control Unit Dimensions 148 x 120 x 232 mm 5 83 x 4 72 x 9 13 in MVE A Ambient Operating Temperature 10 50 ºC 50 122 ºF Vacuum at 6 Bar 90 680 mmHg 26 8 inHg Flow rate 15 SLPM Peripheral Weight 0 7 kg 1 54 lb Peripher...

Page 20: ... s 2 year warranty covers this equipment against all manufacturing defects including the replacement of defective parts and labour Warranty does not cover product wear or misuse In order for the warranty to be valid equipment must be returned postage paid to the dealer where it was purchased Please register your product warranty within 30 days of purchase in www jbctools com productregistration 00...

Reviews:

Related manuals for DDVE-QC