background image

PHXLE-K

XL  Preheater Set

INSTRUCTION MANUAL

www.jbctools.com

Summary of Contents for PHXLE-K

Page 1: ...PHXLE K XL Preheater Set INSTRUCTION MANUAL www jbctools com...

Page 2: ...included Thermocouple 3 units Ref PH218 Kapton Tape 1 unit Ref PH217 Manual 1 unit Ref 0026284 XL PCB Support 1 unit Ref PHXL SA XL Preheater Unit 1 unit RJ45 Cable 1 unit Ref 0019914 Metallic Support...

Page 3: ...12 Connector to Robot Thermocouple Connectors x8 Type K Console 2 8 Color TFT Screen Start Stop USB B Connector RJ45 Connector to Preheater Unit USB A Connector Foot for Vertical Set Up Button for Foo...

Page 4: ...ngle phase Three phase 230V 30 A 10 A 4mm2 1 mm2 100V 120V 60 A 20 A 10 mm2 2 5mm2 PHXLE KA can be connected to single phase or three phase networks A power supply cable is required Use the following...

Page 5: ...llows 1 Unscrew the four screws and remove the cover The cable can be inserted through the front or the side part of the Heating Unit all you have to do is replace the cap with the cable grommet 2 Ins...

Page 6: ...r your working level Arrange the selected supports between the PCB and the Preheater to stabilize the PCB so as to avoid PCB deformatiion Low level High level Medium level 28 mm 38 mm 48 mm To change...

Page 7: ...lift out the PCB Fast PCB Replacement The support lets you replace PCBs of the same batch fast and easily Use the sliding guides to change the PCBs Removing the PCB Placing another PCB Sliding Guide K...

Page 8: ...USB flash drive is connected Station is controlled by a PC Station is controlled by a robot Station software update Press INFO to start the process Warning Press INFO for failure description Error Pre...

Page 9: ...itute for Printed Circuits and is committed to becoming the most recognized international industry association for the electronics manufacturing industry Fix with Kapton Tape Protection Thermocouple S...

Page 10: ...ouple Selected Temp and Mode Control Protection Info Thermocouple Current Temp Select Temp mode from the Work mode menu In this mode the heater unit maintains the selected temperature for the TC1 ther...

Page 11: ...s the same working conditions are respected The profiles which already have the data from the Teach profile are marked with this symbol These profiles can be run either with or without the Thermocoupl...

Page 12: ...many as 25 profiles of temperature Menu Options JBC Set Profiles There are 3 profiles predefined by JBC A B and C The difference between them is the number of steps 2 3 or 4 The thicker your PCB is a...

Page 13: ...Power and Temperature USB ash drive is connected Station is controlled by a PC Station is controlled by a robot System Notifications Station software update Press INFO to start the process Warning Pr...

Page 14: ...ownload the JBC Update File from www jbctools com software html and save it on a USB flash drive Preferably one with no other files 2 Insert the USB flash drive to the console The icon is diplayed whi...

Page 15: ...leaning Alcohol can only be used to clean the metal parts Only if it is absolutely necessary and if cleaning with isopropyl alcohol IPA is not enough it is recommended to use a scraper to remove dirt...

Page 16: ...cause inflamable products to ignite even when out of sight Be careful with the remains of liquid tin In contact with skin it can cause burns Avoid flux coming into contact with skin or eyes to preven...

Page 17: ...Notes 17 www jbctools com...

Page 18: ...Notes 18...

Page 19: ...t Thermocouple type K JBCset Temperature Profiles 3 profiles 2 3 or 4 steps User Profiles 22 up to 6 steps for each Maximum Work Time 600 min or indefinite Dimensions Weight 790 x 664 x 42 mm 18 kg L...

Page 20: ...warranty covers this equipment against all manufacturing defects including the replacement of defective parts and labour Warranty does not cover product wear or misuse In order for the warranty to be...

Reviews: