WARNING:

Connect the VIP Furnace to an individual branch circuit. The overall circuit power rating must
be 15 amps minimum for the 120-volt model and 10 amps minimum for the 230-volt model. No
other devices shall be connected to the circuit powering the VIP Furnace.

Set Up

1. Install cooling tray, if necessary.
2. Connect vacuum pump.
3. Connect compressed air line.
4. Connect input power line cord.
5. Turn on power. Observe that the door opens (lowers).
6. Place firing block with ring insert in place on to door platform.

Important:

Run the muffle conditioning program whenever furnace has been off,
cooled down and then turned on.

Muffle Conditioning

Run muffle conditioning program # 400 

two times

as follows:

1. Press the 

PROGRAM SELECT

key.

2. Enter digits 

4 0 0

and press the 

ENTER/REVIEW

key.

3. Press the 

START

key.

VIP UNIVERSAL X-PRESS FURNACE

Pressable Ceramic Firing Programs # 0 through 19

Q u i c k   S t a r t   G u i d e

VACUUM PUMP

POWER

SOCKET

COOLING TRAY

Introduction

This guide provides brief setup and user instructions to quickly allow the operator to start using the
Pressable Ceramic Firing Programs # 0 through 19 for VIP Universal X-Press Furnace operation.
For more detailed information, refer to the Instruction Manual supplied with the furnace. 

COMPRESSED

AIR HOSE

CONNECTION

POWER

LINE CORD

CONNECTOR

VACUUM PUMP

HOSE

CONNECTION

Figure 1. VIP Furnace Setup 

©

2006 Air Techniques Inc.

PN A4124, Rev. A