background image

GPN 217389

Jindara Cottage

Operation & Installation Instructions

REV. C

woodheating

• Smoke entering the room from the firebox when the door is open may be caused by

• Insufficient length of flue (Flue to be 4500mm minimum from underneath base of heater to underside of cowl)
– Increase height of flue.
• Flue Downdraught
– Consult dealer or increase height of flue.
• Creosote Build up in flue
– Remove cowl and clean flue as per cleaning instructions. Check moisture content of wood.

• Excessive ash build up

Some woods will give large amounts of ash despite how you run the heater. Others will give you very little. Use the wood which is most
convenient for you as long as it is dry. After a period of time you will get to know when to empty your unit. Always leave 12mm of ash
in the bottom of your heater. Bark will give you excessive ash. Try not to burn it.
If you are burning wood that gives you charcoal, you may find that after running the heater say for 8 hours at maximum burn rate, the
charcoal builds up excessively. Overnight burn will reduce this charcoal back to a fine ash. If you are not ready to shutdown for
overnight burn when you next fuel the stove, load the stove with only one piece of wood and lay it across the firebox on top of the
charcoal. Open the air control wide open and you will find the charcoal will burn down with the one piece of wood. Repeat the process
until the ash level is significantly reduced.

The Jindara Cottage

8

Troubleshooting  

(Continued)

1. Subject to clauses 2 & 3 of this warranty, A.F. Gason Pty Ltd ACN 004 667 556 (Gason) warrants the following components of its heaters against defects in workmanship and/or materials for the

following periods from the date of purchase:

(a) the firebox for one year;
(b) the paint finish for a period of twelve months if the purchaser has followed the instructions provided by Gason in this Operation and Installation Instructions manual; and 
(c) all other components for twelve months except the glass, fire brick lining or baffle plate if, in the opinion of Gason, these items have been damaged by impact.
2. This extended warranty does not apply:
(a) if the heater is purchased from a person who has not been authorised by Gason to sell its products; 
(b) if, in the opinion of Gason, the heater or any component has been subjected to abuse, misuse, alteration, modification or has not been installed, operated or maintained in accordance with the

instructions provided by Gason; or

(c) to owners other than the original purchaser.
3. If you believe that the heater you purchased contains a manufacturing defect and you wish to make a claim under this warranty, please contact an authorised Gason service centre to arrange for an

assessment. 

4. If, after assessing the heater, Gason determines that the heater contains a manufacturing fault, Gason may at its discretion:
(a) replace the heater;
(b) repair or replace specific components of the heater; or
(c) provide a full refund.
5. Parts replaced under this warranty are warranted for the balance of their original warranty period.
6. If, at the discretion of Gason, the heater or any part needs to be replaced, serviced or repaired at an authorised Gason service centre, then the person claiming under this warranty must pay all costs

associated with:

(a) returning the heater; and 
(b) the delivery or collection of any new or repaired heater. 
Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably
foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.

Any benefits you receive under these warranties are in addition to other rights and remedies that you may have as a consumer under a law in relation to the heater to which these warranties relate. 

These warranties are given by:

A.F. Gason Pty Ltd
Blake Street
Ararat VIC 3322

Please contact us if you have any queries on:

Phone: 03 5352 2151;
or email us via the “Contact Us” section of our website: www.gason.com.au. 

Jindara Heating reserves the right to modify or alter specifications, materials, etc. in the interest of product improvement.

WARRANTY

Summary of Contents for Cottage

Page 1: ...se items have been damaged by impact 2 This extended warranty does not apply a if the heater is purchased from a person who has not been authorised by Gason to sell its products b if in the opinion of Gason the heater or any component has been subjected to abuse misuse alteration modification or has not been installed operated or maintained in accordance with the instructions provided by Gason or ...

Page 2: ...sh can be damaged if the door is left open for a long period with a full firebox of fuel Closely supervise your heater while the door is left open Closing the Door Always ensure that before you close your door there is no wood protruding beyond the front of the firebox opening Do not use the door glass as a battering ram to push the wood back into the firebox Damage to the glass by such impact is ...

Page 3: ...e air control to the setting you have found best for your requirements The aim when overnight burning is to have only a few hot embers left in the bottom of the firebox in the morning Not huge lumps of wood Note Not all woods will last overnight Cleaning your flue Carefully remove baffle plate and put it to one side Close the firebox door and position flue damper control in the open position using...

Page 4: ...r control in open position refer illustration on page 6 for flue damper control location When the kindling is burning place about four pieces of small wood on top of the burning kindling Once the wood is alight close the main door After approximately 20 minutes turn the air control down to medium On the initial fire up you may detect smoke coming from the paint finish and from any oils that may be...

Reviews: