background image

Skan 60.0

Battery Charger 

JM-No. 609 01 99

Thank you for choosing a JMP Skan battery charger. The JMP Skan 60.0 battery charger is suitable for use as a 

power source for the diagnosis/flashing of control units and the charging of batteries.

Technical data:

12 V / 5-60 A, for batteries from 5 Ah to 600 Ah

Dimensions: 300 x 400 x 150 mm, weight: 5.9 kg, power cable: 1.7 m, connection cable: 2.7 m

Suitable for:

•  Standard lead acid

•  Gel

•  AGM

•  EFB

•  Lithium (LiFePO4)

Safety information:

•  Please read this operating manual through carefully before using the battery charger. Failure to comply with 

this safety information can result in serious injuries.

• 

The device must not be used for purposes other than those specified herein.

• 

Do not use the device in explosive atmospheres or in the vicinity of flammable materials, as it may produce 

sparks which can ignite dust or fumes.

•  Store out of reach of children. This device is not a toy and must not be used as such.

•  Do not inhale any gases escaping the battery.

•  The battery acid is corrosive. In case of accidental contact between the acid and the skin or eyes, rinse imme-

diately under running water and consult a doctor.

•  Use the battery charger in a dry, well ventilated environment and avoid moisture.

•  Verify that the device is in full working order before using it.

• 

Improper use and unauthorised modification of the device void all warranty claims.

•  Always wear safety goggles and protective clothes when connecting and disconnecting the battery and keep 

the battery away from your face.

•  Never allow the two clips to come into contact with each other.

•  The device and power cable must only be repaired and serviced by authorised specialist personnel.

• 

Switch off all unnecessary consumer loads in the vehicle before connecting up the device.

Scope of supply:

JMP Skan 60.0, adapter cable with clips,

power cable

Summary of Contents for Skan 60.0

Page 1: ...ce sparks which can ignite dust or fumes Store out of reach of children This device is not a toy and must not be used as such Do not inhale any gases escaping the battery The battery acid is corrosive In case of accidental contact between the acid and the skin or eyes rinse imme diately under running water and consult a doctor Use the battery charger in a dry well ventilated environment and avoid ...

Page 2: ...60 A 30 A 15 A 5 A Recovery Regenerating mode for sulphatised batteries Select by holding the function key depressed for 3 seconds display REC No error messages are displayed during the charging process An increased voltage of 15 5 V is forced Note Only run recovery mode with the battery disconnected from the ve hicle in order to avoid damage Do not charge lithium batteries in recovery mode under ...

Page 3: ...tandard lead acid gel AGM EFB lithium LiFePO4 1 Connect the device to the battery vehicle as previously described 2 Select the CHARGE mode using the function key 3 Then use Amperage to select the battery capacity and Volt Batt to select the battery type 4 Use the Start Stop key to start the supply of electricity 5 Use the Start Stop key to stop the charging process The power cable mode FLASH Exten...

Page 4: ...ery Battery likely defective Er03 Battery charger overheated Device overloaded Ensure that the ventilation system is not blocked or move the device to a cooler location Er04 Voltage error battery voltage too low Use Recovery mode Only use the device with 12 V batteries Restart the charging procedure Battery with one or multiple short circuited elements Battery likely defective Er05 Battery with to...

Page 5: ...for 5 minutes If the voltage drops below 11 7 V during this time the charging is cancelled If not phase 4 begins In case of a short circuited element or sulphatisation Er02 charging in Recove ry mode is recommended 4 Bulk intensive charging Charges the battery to the defined maximum permissible value 5 Stable constant voltage The battery is maintained at the end of charge voltage 6 Analysis A3 Fin...