background image

Joerns

Healthcare

User-Service Manual

Joerns

®

 Lifting and Repostioning

Model C-HLA-2

redefining patient handling

To avoid injury, read user’s manual before using.

Summary of Contents for C-HLA-2

Page 1: ...Joerns Healthcare User Service Manual Joerns Lifting and Repostioning Model C HLA 2 redefining patient handling To avoid injury read user s manual before using...

Page 2: ...shipping errors to your supplier Include all equipment identification numbers and group part numbers if any as described above along with a full description of damaged goods Important Precautions War...

Page 3: ...der and replace all labels that cannot be easily read Caution Use pump to raise boom into position for lifting patient Caution DO NOT lift up on end of boom when positioning to prepare for lifting pat...

Page 4: ...ion of Hydraulic Pump Stud 7 Operation 8 Leg Spreader Operation Lifter Maintenance Checklist 10 Troubleshooting 11 Hoyer 4 point Sling Information 12 Warranty 14 Specifications Base Adjustable U Maxim...

Page 5: ...is when lifting a patient from the floor the locks should be engaged during a floor lift 1 Carefully unpack Hoyer Lifter Check for swivel bar 6 point cradle and adjusting lever handle 2 Insert mast in...

Page 6: ...d secure tightly Figure 6 d Swivel cradle to check for free movement 7 Attach adjusting lever handle into base Figure 7 8 Wheel locks are provided for parking To lock caster step on cam lever on side...

Page 7: ...2 3 4 and 5 are correctly assembled Figure 9 6 Tighten nut 2 until it lightly contacts the nylon washer 1 Loosen the nut 2 by 1 2 turn so that the pump rotates freely in U bracket 3 Check that the st...

Page 8: ...imize stability Figure 11 2 Pump hydraulic handle Figure 12 Do not lock rear casters If needed lifter base will move slightly to adjust for balance To Lower Lifter 1 Open hydraulic pressure release kn...

Page 9: ...e a faulty pump but is a trait common to hydraulic equipment 4 If trouble develops with the hydraulic pump remove it and call your Joerns Healthcare Supplier to receive an RMA Provide serial number lo...

Page 10: ...bolts and nuts for wear and tightness Boom Inspect all bolts and nuts for wear and tightness Inspect to ensure the boom is centered between the base legs Cradle Check hanger post for wear or damage R...

Page 11: ...of oil for a jack when completely empty are 7 3 4 oz for 12 stroke 11 1 2 oz for 17 stroke 3 3 4 oz for 6 stroke 12 1 2 oz for 19 stroke Oil leaking from around piston Replace the jack Oil leaking ar...

Page 12: ...cturer s sling with the C HLA 2 Lifter Note Do not use Hoyer slings with any other manufacturer s lift Patient Size Guide A B Weight inch cm inch cm lbs kg Large 28 70 19 47 198 400 90 191 Medium 24 6...

Page 13: ...13 Joerns Lifting and Repositioning C HLA 2 Lift Notes...

Page 14: ...unless performed by or authorized in writing by Joerns Healthcare will void this warranty This warranty applies in the USA only Check with your supplier to find out if international warranties apply P...

Reviews: