background image

PXIe-2519 Chassis

User Manual

User Manual Version:

1.0.3

Revision Date:

September 10, 2021

Summary of Contents for PXIe-2519

Page 1: ...PXIe 2519 Chassis User Manual User Manual Version 1 0 3 Revision Date September 10 2021 ...

Page 2: ... Mechanical Dimensions 9 Front and Rear Panels 13 2 4 1 Front Panel 13 2 4 2 Rear Panel 14 2 4 3 Chassis Status LED 14 2 4 4 Fan Mode 15 Chassis Cooling Considerations 16 2 5 1 PXI PXIe Modules Cooling 16 2 5 2 Power Supply Cooling 17 3 Performance Test 18 PCI Bus Throughput 18 PCIe Bus Throughput 20 4 Software 23 Introduction to JYDM 23 Installation and use of JYDM 23 Chassis environment monitori...

Page 3: ...2519 Gen 3 Gen 2 9 Figure 5 Right Side View PXIe 2519 Gen 3 Gen 2 10 Figure 6 Rear View PXIe 2519 Gen 3 Gen 2 10 Figure 7 Top View PXIe 2519 Gen 3 Gen 2 11 Figure 8 Bottom View PXIe 2519 Gen 3 Gen 2 12 Figure 9 Front Panel 13 Figure 10 Rear Panel 14 Figure 11 PCI Bus Throughput for segment 1 18 Figure 12 PCIe Bus Throughput 21 Figure 13 Install the JYDM 23 Figure 14 Monitoring the Chassis Power Ra...

Page 4: ...on Clock 7 Table 4 Continuous Current Capability 7 Table 5 Environment 8 Table 6 Acoustic Emissions 8 Table 7 Backplane 8 Table 8 Chassis Size and Weight 8 Table 9 Front Panel 13 Table 10 Rear Panel 14 Table 11 PCI Bus Throughput 19 Table 12 PCIe Bus Throughput 20 ...

Page 5: ...CIe link speed capability PXIe 2519 series provide two models as shown in Table 1 Table 1 PXIe 2519 series model name Note system bandwidth defined as data rate between controller and chassis backplane slot bandwidth defined as data rate between peripheral module and chassis backplane Main Features High data throughput 9 slot PCIe Gen2 PXIe 2519G2 or Gen3 PXIe chassis PXIe 2519G3 High clock accura...

Page 6: ...PXIe 2519 jytek com 2 2 Hardware Backplane Overview 2 1 1 Backplane Architecture Figure 1 PXIe 2519 Gen3 Backplane Architecture Figure 2 PXIe 2519 Gen2 Backplane Architecture ...

Page 7: ...ovides eight hybrid peripheral slots It can accept the following peripheral modules PXI Express Peripheral Module CompactPCI Express Type 2 Peripheral Module Hybrid slot compatible PXI 1 Peripheral Module CompactPCI 32 bit Peripheral Module Figure 3 PXIe 2519 Peripheral Slot Compatible Modules Each peripheral slot PCIe link can support Gen3 x4 PXIe 2519G3 or Gen2 x4 PXIe 2519G2 providing maximum s...

Page 8: ... the left and right which by routing PXI Local Bus 6 signal between adjacent peripheral slots 2 1 6 System Reference Clock and Synchronization Signal The PXIe 2519 supplies 10MHz reference clock PXI_CLK10 100MHz reference clock PXIe_CLK100 and synchronization signal PXIe_SYNC100 to each peripheral slot for inter module synchronization The PXIe 2519 has the default timing relationship of PXI_CLK10 ...

Page 9: ...PXIe 2519 jytek com 5 Specifications 2 2 1 Basic Table 1 Basic Specification 2 2 2 Electrical ...

Page 10: ...PXIe 2519 jytek com 6 Table 2 Electrical Specification 2 2 3 System Synchronization Clock ...

Page 11: ...PXIe 2519 jytek com 7 Table 3 System Synchronization Clock 2 2 4 Continuous Current Capability Table 4 Continuous Current Capability ...

Page 12: ...PXIe 2519 jytek com 8 2 2 5 Physical and Enviornment Table 5 Environment Table 6 Acoustic Emissions Table 7 Backplane Table 8 Chassis Size and Weight ...

Page 13: ...PXIe 2519 jytek com 9 Mechanical Dimensions All dimensions are shown in mm millimeters Figure 3 Front View PXIe 2519 Gen 3 Gen 2 Figure 4 Left Side View PXIe 2519 Gen 3 Gen 2 ...

Page 14: ...PXIe 2519 jytek com 10 Figure 5 Right Side View PXIe 2519 Gen 3 Gen 2 Figure 6 Rear View PXIe 2519 Gen 3 Gen 2 ...

Page 15: ...PXIe 2519 jytek com 11 Figure 7 Top View PXIe 2519 Gen 3 Gen 2 ...

Page 16: ...PXIe 2519 jytek com 12 Figure 8 Bottom View PXIe 2519 Gen 3 Gen 2 ...

Page 17: ...PXIe 2519 jytek com 13 Front and Rear Panels 2 4 1 Front Panel Figure 9 Front Panel Table 9 Front Panel ...

Page 18: ...PXIe 2519 jytek com 14 2 4 2 Rear Panel Figure 10 Rear Panel Table 10 Rear Panel 2 4 3 Chassis Status LED Table 3 Chassis Status LED ...

Page 19: ...ed on the measured temperature of sensor Fans run at 40 duty cycle if the measured temperature less than 40 C and begin ramping up when any temperature reading exceeds 40 C Fans run at 100 duty cycle full speed if any temperature reading exceeds 65 C When the Fan Switch is set to HIGH mode fans run at 100 duty cycle immdiately The factory default fan control curve shows as following Figure Figure ...

Page 20: ...erations 2 5 1 PXI PXIe Modules Cooling For PXI PXIe modules cooling there are two fans on the underside of the chassis draw cool air from the bottom side of chassis to be exhausted to the top sides of the chassis Figure 9 PXI PXIe Modules Cooling ...

Page 21: ...tek com 17 2 5 2 Power Supply Cooling For power supply cooling power supply s fan draws cool air from the right side to be exhausted through the left side and rear side of the chassis Figure 10 Power Supply Cooling ...

Page 22: ...PCI Bus Throughput PXIe 2519G3 G2 provides excellent throughput of PCI Bus as shown in below There are two PCI Bus segments in the backplane Slot2 to Slot5 is segment 1 and Slot6 to Slot9 is segment 2 Figure 11 PCI Bus Throughput for segment 1 ...

Page 23: ...9 jytek com 19 Figure 13 PCI Bus Throughput for segment 2 Table 11 PCI Bus Throughput Note PCI Bus theoretical maximum bandwidth is 132 MB s PXI 69846H is 4 ch 40 MS s 16 bit digitizer its bandwidth is 320 MB s ...

Page 24: ...PXIe 2519 jytek com 20 PCIe Bus Throughput PXIe 2519G3 provides excellent throughput of PCIe Bus as shown in below Table 12 PCIe Bus Throughput ...

Page 25: ...PXIe 2519 jytek com 21 Figure 12 PCIe Bus Throughput ...

Page 26: ... jytek com 22 Note Slot 1 is the system bandwidth test its theoretical maximum bandwidth is 16 GB s PCIe Gen3 x16 Slot 2 to 5 are the slot bandwidth test its theoretical maximum bandwidth is 4 GB s PCIe Gen3 x4 ...

Page 27: ...nagement driver and firmware online upgrade online driver version management board test panel JYTEK SeeSharp card driver information view test panel Installation and use of JYDM JYDM support operating system Windows 7 32 64 bit Windows 10 32 64 bit 1 Install Net framework version 4 0 or above 2 Download and install FirmDrive version 1 3 3 or above from the official website of JYTEK 3 Download and ...

Page 28: ...verall system as shown in the figure below Note JYDM usually requires a few seconds to scan device The left side of the JYDM interface is the hardware device column and the right side is the device details column You can view and configure the current device information and upgrade the driver and firmware Figure 15 JYDM GUI application program ...

Page 29: ...s two parts the shared common driver kernel software FirmDrive and the specific peripheral module driver After firmware update of peripheral module you need to cold restart your device After driver update of peripheral module you need to warm restart your device ...

Page 30: ... rails 5Vsb standby power 3 3V 5V 12V and 12V DC power Figure 14 Monitoring the Chassis Power Rails Monitoring the chassis temperature sensors T1 sensor is located on the top side of slot1 Figure 15 Monitoring the Chassis Temperature Sensors Monitoring the chassis fan speed Fan1 module ia located on the bottom side of slot1 Figure 16 Monitoring the Chassis Fan Speed ...

Page 31: ...ies the chassis temperature at which the maximum fan speed 100 duty cycle is achieved as shown in below figure Figure 16 Factory default Target Temperature setting The factory default target temperature setting is 65 C User can change target temperature to lower value ex 45 C it will increase fan speed if the factory default setting could not fulfill the peripheral modules cooling requirement ...

Page 32: ...PXIe 2519 jytek com 28 Figure 17 Change Target Temperature to 45 C ...

Page 33: ... or higher from NI website Figure 18 Install NI MAX Open JYDM set Valid PXI Resource Manager and Default PXI Trigger Manger to National Instruments and then click Save to save the settings Figure 19 Change PXI Trigger Manager Setting Open NI MAX after software installation and the devices can be identified ...

Page 34: ...PXIe 2519 jytek com 30 Figure 18 NI MAX GUI display JYTEK chassis and modules ...

Page 35: ...lease visit our web www jytek com to download Using PXIe 2519 with National Instruments PXI PXIe Peripheral Modules 5 2 1 Use National Instruments PXI PXIe Peripheral Modules without synchronization You can use the modules as usual without any additional setting Chassis may not display correctly in NI MAX but this will afftect nothing with module functions 5 2 2 Use National Instruments PXI PXIe P...

Page 36: ...e 2519 jytek com 32 But you can use DAQmx Export Signal to set appointed clock trigger routing Figure 21 DAQmx Export Signal DAQ synchronization reference code Figure 22 DAQ Synchronization Reference Code ...

Page 37: ...ck Mount Kits JYTEK provides optional hardware for installation of PXIe 2519 chassis into a server or rack The rack mounting kits dimension as following figure All dimensions are shown in mm millimeters Figure 25 PXIe 2519 rack mount kits dimension ...

Page 38: ... JYTEK Korea was the first JYTEK enterprise outside China to promote JYTEK products Together with Adlink Technologies and JYTEK China JYTEK is expanding to more countries Each JYTEK location is an independently owned and operated franchise It shares JYTEK s philosophy and business approach Together JYTEK entities promote the JYTEK brand technology and products JYTEK Hardware Products According to ...

Page 39: ...sition JYTEK Software Platform JYTEK has developed a complete software platform SeeSharp Platform for the test and measurement applications We leverage the open sources communities to provide the software tools Our platform software is also open sourced and is free thus lowering the cost of tests for our customers We are the only domestic vendor to offer complete commercial software and hardware t...

Page 40: ...tual property rights unless such disclaimer is legally invalid JYTEK is not responsible for any incidental or consequential damages related to performance or use of this manual The information contained in this manual is subject to change without notice While we try to keep this manual up to date there are factors beyond our control that may affect the accuracy of the manual Please check the lates...

Reviews: