background image

COMBOGARD

33E Firmware
3040-DB Deadbolt Lock & 4100 Swingbolt Lock

Manager prograMMing

STANDARD FEATURES

WRONG TRY PENALTY

•  Four (4) consecutive invalid combinations initiates five (5) minute delay period.

LOW BATTERY WARNING

•  Repeated LED flashing and beeping during opening indicates battery
  is low and needs immediate replacement.

AUDIO AND VISUAL SIGNAL

•  Double signal - two (2) LED flashes and two (2) unit beeps - indicates
  entry is valid or accepted.  
•  Triple signal - three (3) LED flashes and three (3) beeps - indicates
  invalid or not accepted.

PROGRAMMABLE MODES 

ACTIVE

(3045 Handheld Programmer Required)
MANAGER COMBINATION

 (Factory set to 1-2-3-4-5-6) ...............

£

•  Add/Remove User
•  Enable/Disable User

USER COMBINATION

 .....................................................................

£

•  Open Lock
•  Change Combination

TIME DELAY OVERRIDE MODE

 ....................................................

£

•  Ability to add second combination to override delay period

DUAL COMBINATION MODE

 .........................................................

£

•  Add User
•  Both combinations required to open

PROGRAMMABLE FEATURES (3045 Handheld Programmer Required)
TIME DELAY

 ....................................................................................

£

•  Delay period 1 - 99 minutes
•  Open period 1 - 19 minutes

SILENT SIGNAL ALARM

 (Optional Alarm Box Required) ...............

£

•  Duress signal if last number of combination is entered using one
  number higher or one number lower.

DISABLE LOCK

 (Optional Alarm Box Required) .............................

£

•  Input signal disables opening of lock by valid combination.

OPENING THE LOCK

1. Enter valid six (6) digit combination.
2. The lock will indicate a valid combination with a double signal.
3. Within four (4) seconds, turn the keypad to the open position
  (clock-wise) if using a dead bolt style lock, or turn the handle to the
  open position if using a swing bolt style lock.
4. Pull door open.
•  Invalid Combination - Lock will signal three (3) times.

CHANGING YOUR COMBINATION

ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN
(If your unit is programmed for Dual Mode, each combination must 
be changed independently. Follow these instructions for each 
combination change.)

1. Enter “zero” six times.
2. Enter your existing six (6) digit combination one time.
3. Enter your NEW six (6) digit combination two times.
4. If a mistake is made wait thirty (30) seconds and repeat steps 1 - 3.
5. Test lock operation several times before closing the door.

CAUTION: When selecting a combination do not use birthday or 
other predictable data that could give correlation between the 
user and the combination. Keep the combination secret. 

•  Valid Combination - Double signal after valid six (6) digit
  combination is entered.
• Invalid Combination - Triple signal indicates the old combination is
  still valid.

ADD USER

 

(ONLY available if either Manager Mode, Time Delay 

Override Mode or Dual Mode was activated using the 3045 Hand Held 
Programmer. Add User is not available if Remote Override feature is 
activated using the 3045 Hand Held Programmer.)
ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN

1. Enter the Manager combination and 

hold down last digit of the 

combination until the lock signals with two sets of double beeps.

2. 

PRESS 1.

 Lock signals as follows:

    One beep – User is already installed (end of operation)
    Two beeps – User enabled, go to Step 3 
    Three beeps – Not available; Function was not programmed with
    Hand Held Programmer (end of operation) 
3. Enter 

NEW

 user combination twice. The lock signals twice after

  each valid entry.
4. If a mistake is made wait thirty (30) seconds and repeat steps 1 - 3.

© copyright 2006  

(P/N)12-203 v5 • 6/08 

Kaba Mas LLC

page 1 of 2

4200 Swingbolt Lock

3740-2 Deadbolt Lock

SUggESTED KEyPADS:

3035 Entry

3750 Entry

3190 Privat

II