Mounting instructions 71111 President A
– 71113 President
1. General Information
These mounting instructions are the basis for the approval by ECBS, VdS, A2P (CNPP)- DNV, UL. Installation of the
lock to be performed exclusively in accordance with these instructions.
Guidelines of the national certification bodies are to be considered and complied with in addition.
Attention: The lock bolt of version 71113 with option “Not Key Retained” (Optioncode SAB) is not arrested in
position “lock open”.
Any variation of the lock or key may result in functional trouble and must better not be done. All claims under guarantee
and warranty will expire in this case.
Prevent the ingress of dirt into the lock.
Lock fastening: Use of M6 steel socket head cap screws or BSW ¼" steel bolts. The length of engagement must
correspond to the applicable standards considering the thickness of the lock of 22 mm.
Fastening screws: minimum property class 4.8 and maximum property class 8.8.
Screws to be secured either by lock washer, flat spring, tooth lock washer, fan type lock washer considering the diameter
(d1) or to be cemented.
Screw tightening moment: minimum 5 Nm and maximum 6 Nm.
The bolt must be floating in installed condition.
It is recommended, that unauthorized persons have no access to security sensitive parts of the lock, also the door of the
safe, where the lock is installed, is open.
Perfect function of the lock and of any additional connected or triggered systems (e.g. boltworks) must be warranted and
checked by specialists during installation of the lock.
2. Mounting Position
Lock mounting position
RH version (standard version):
LH version (special version for LH applications):
Bolt left, keyhole horizontal
Bolt right, keyhole horizontal
Bolt downwards, keyhole vertical
Bolt downwards, keyhole vertical
Bolt upwards, keyhole vertical
Bolt upwards, keyhole vertical
3. Specification Key Guide and Key Hole
Use of the Kaba Mauer key guide (see Fig. 1) or of the Kaba Mauer key carrier guide (see Fig. 2) is recommended.
Considering DIN 2768-mH, the keyhole in the door of the secure storage unit should be dimensioned accordingly (see
Fig. 1 or 2).
Fig. 1: Key guide 86101
Fig. 2: Key carrier guide 86102
R
4
R4
O
8
4,
2
4,
2
5,
9
5,
9
25,5
12,75
26
4,6
4,6
13
O
12
,5
R1
R
1
R
1
R
1
7,5
3,5
70
°
140
°