background image

EN

Kaba digital cylinder

User manual

Doc. no.:  k1evo805en-2012-09

Summary of Contents for 1434LEA

Page 1: ...EN Kaba digital cylinder User manual Doc no k1evo805en 2012 09 ...

Page 2: ...e 2 Mühlebühlstrasse 23 Tiverton Industrial Estate 3130 Herzogenburg 8620 Wetzikon Tiverton Devon Austria Switzerland EX16 655 www kaba co uk www kaba com www kaba com This documentation may not be reproduced in any way or otherwise used without the written consent of Kaba AG Kaba is a registered trademark of Kaba AG copyright by Kaba AG 2012 ...

Page 3: ... 7 2 2 2 ESD protective measures for installation 8 2 2 3 Areas of use 8 2 2 4 Disposal of packaging 9 2 2 5 Disposing of digital cylinders and batteries 9 3 Product description 10 3 1 Scope of supply 10 3 2 Additional accessories 10 3 3 Types 10 3 4 Technical specifications 11 3 4 1 Cam position of the anti panic digital cylinder 12 3 5 Design of the digital cylinder 13 3 6 Dimensions 13 4 Operat...

Page 4: ... 7 2 3 Restore factory settings 36 7 3 Programming with programmer and software 37 7 3 1 Programming with the programmer 37 8 Maintenance and fault rectification 39 8 1 Servicing 39 8 1 1 Maintenance interval for digital cylinder and digital anti panic cylinder 39 8 1 2 Maintaining digital cylinders on emergency exit doors 39 8 1 3 Replacing the battery 41 8 1 4 Setting the clock 41 8 1 5 Reading ...

Page 5: ...tem and does not replace product training 1 3 Content and purpose The content of the user manual is limited to installation programming operation and maintenance of the Kaba digital cylinder 1 4 Supplementary documentation Technical information and help in the planning of installations can be found in the technical data sheets or the Kaba evolo product catalogue Detailed information on programming...

Page 6: ...t are explained in the glossary on page 45 In order to simplify the user manual for the reader the mechatronic locking cylinder Kaba digital cylinder is referred to as digital cylinder for short and the programming device Kaba Programmer 1460 is referred to as programmer for short WARNING Indicates a potentially dangerous situation that could lead to serious injury or death CAUTION Indicates a pot...

Page 7: ...uct 2 2 1 Handling of lithium batteries WARNING Risk of personal injury or death Incorrectly used or installed digital cylinders prevent emergency exit closures or panic closures from opening Risk of explosion Lithium batteries can explode or burst explosively Improper handling of lithium batteries can lead to fires and explosions Follow the instructions below Only replace lithium batteries by bat...

Page 8: ... lock manufacturers EC conformity certificates If the digital cylinder is not listed on the certificates from the lock manufacturer or the lock does not comply with these standards an EC conformity inspection of the lock digital cylinder door furniture and assembly accessories as one unit must be carried out The use of a digital cylinder must be checked carefully before using it in locks with a pa...

Page 9: ...waste Electrical devices must be disposed of in line with the waste disposal and environmental guidelines applicable in the relevant country Disposal in Germany Kaba devices are registered as B2B in the Register of Used Electrical Equipment Elektro Altgeräte Register Kaba guarantees the return and disposal of the product Do not dispose of used batteries with household waste Used batteries must be ...

Page 10: ...m 1 quick start guide 3 2 Additional accessories Kaba service tool item number 1430 25 Hexagonal screw hex 1 5 mm item number 1430 55 Programmer 1460 Kaba media Kaba evolo Manager software 3 3 Types MID MIFARE DESFire supports MIFARE classic LEA LEGIC advant supports LEGIC prime 17 mm profile cylinder 22 mm round profile Standard 1435MID 1435LEA 1535MID 1535LEA Half 1434MID 1434LEA 1534MID 1534LEA...

Page 11: ...oor Standard internal knob 35 mm Outward opening door Dual internal knob 25 mm Outward opening door Small internal knob Power supply Battery 3 V CR2 Lithium type Operating environments Protection class External knob IP55 Temperature 25 70 C 1 Humidity 0 95 rH non condensing Climate Not suitable for corrosive atmospheres chlorine ammonia Battery life at 20 C up to 65 000 cycles 2 Certificates SKG P...

Page 12: ...ithout reset can be seen from the diagrams No modifications of any type are permitted with the exception of those detailed in this user manual a upper authorised rest area b lower authorised rest area ATTENTION Only install the digital cylinders in panic locks that are certified for use in emergency exit doors In accordance with certificate from the lock manufacturer Use of the digital cylinders i...

Page 13: ...le cylinder Dimension drawing 1435 Standard 17 mm profile cylinder Description for Standard version Item Item 1 External knob 8 Securing shackle 2 Cover with illumination 9 LA length on outer side 3 Electronical module with antenna 10 LB Length on inner side 4 Battery 11 Cylinder housing 5 Bayonet disc 12 Cam 6 O ring Ø 15 x 1 mm 13 Internal knob 7 MC Insert 14 Hexagonal screw 2 3 6 7 11 12 14 13 ...

Page 14: ...knob 17 mm profile cylinder Dimension drawing 1439 Dual 17 mm profile cylinder With the cylinder lengths leave a gap of at least 1 mm between the door furniture and the door knob so that the service tool can be used on the door knob The anti panic digital cylinder type 1537 round profile has a continuous bridge on the inside LB 45 LA 10 5 3 M5 32 3 6 3 LA LB 3 5 45 27 26 32 M5 26 30 LA LB 3 3 45 4...

Page 15: ...he doors The user media are electronic keys Each digital cylinder recognises its own user media and only grants access authorisation to these media All user media must be programmed with an access authorisation prior to first use User media 1 Hold an authorised user medium in front of the digital cylinder as shown 2 The short acoustic signal if activated and the optical green display indicate that...

Page 16: ...While user media are held up in front of the digital cylinder this cylinder emits various acoustic and optical signals The acoustic and optical signals can be activated or deactivated using the programmer The factory settings are that the optical signals are activated and the acoustic signals are deactivated The signals have the following meaning Access with user media Acoustic signal Optical disp...

Page 17: ...use the mechatronics unit engages When the battery is almost empty the 2 x long acoustic signals and the 4 second pause remind the user to insert a new battery so that the doors can continue to be opened or closed Acoustic signal Optical display Hold up an authorised medium 1 x long off The mechatronics unit does not engage The battery is discharged Replace the battery Acoustic signal Optical disp...

Page 18: ...rend locking stud size PZ 2 5 2 Installation variants With installation variant A remove the inner door knob and push the cylinder through the door furniture and the lock from the outer side of the door With installation variant B remove the outer door knob and also the inner door knob if necessary and push the cylinder housing through the door s lock 1 The furniture on the inner side requires a r...

Page 19: ... the lock and door furniture manufacturers are observed Check the dimensions 1 Check the door thickness with the door furniture LA and the cylinder length 2 Check the profile cutout and the backset D With the cylinder lengths leave a gap of at least 1 mm between the door furniture and the door knob so that the service tool can be used on the door knob VdS guidelines stipulate that for doors with b...

Page 20: ...stallation A from the outer side of the door 1 Using the hexagonal key loosen the screw from the inner door knob 2 Remove the inner door knob 3 Align the cam flush with the cylinder housing 4 From the outer side of the door push the digital cylinder through the door furniture and the lock 5 Position the forend locking stud in the lock and tighten it slightly 6 Push the inner door knob onto the cyl...

Page 21: ... stud 9 Check that the door knobs function correctly Both door knobs can be turned without touching the door furniture 10 Check the backset The door knobs must not knock against the door frame 11 Insert the battery See page 28 12 7 8 9 9 WARNING After installing the digital cylinder in a panic lock a function check must be carried out It must be possible to open the lock with the lever handle in a...

Page 22: ...lock by turning the door knob 14 Turn the inside knob of the digital cylinder clockwise until just before the upper rest area 11 o clock position 15 Hold this position in doing so it should be possible to feel the reset force 16 Press down the lever handle which should open the latch the bar and the door 17 Let go of the inside door knob the inside knob should return to the neutral area 5 7 o cloc...

Page 23: ...from electrostatic discharge Installation B from the inner side of the door 1 Position the service tool on the inner side of the outer door knob 2 Turn the service tool clockwise and unlock the outer door knob 3 Remove the outer door knob 4 Attach the service tool to the securing shackle from below 5 Push out the securing shackle and remove the door knob module 6 Using the hexagonal key loosen the...

Page 24: ...nual 8 Remove the door furniture without profile cutout 9 Align the cam flush with the cylinder housing 10 Push the cylinder housing through the lock from the inner side of the door 11 Position the forend locking stud in the lock and tighten it slightly 8 8 9 10 11 ...

Page 25: ...he screw using the hexagonal key 15 Check the position of the O ring Push the electronical module onto the cylinder housing ensuring that the O ring is not damaged in the process 16 Push the securing shackle into the electronical module from above to the end stop position The electronical module and the cylinder housing are now firmly connected 12 12 13 14 15 16 ...

Page 26: ...e outer door knob over the electronical module 19 Attach the service tool to the outer door knob 20 Rotate the service tool anticlockwise and lock it The outer door knob and the cylinder housing are now firmly connected 21 Tighten the forend locking stud 22 Check that the door knobs function correctly Both door knobs can be turned without touching the door furniture 23 Check the backset The door k...

Page 27: ...s position in doing so it should be possible to feel the reset force 27 Press down the lever handle which should open the latch the bar and the door 28 Let go of the inside door knob the inside knob should return to the neutral area 5 7 o clock position automatically 29 Turn the inside knob of the digital cylinder anti clockwise until just before the upper rest area 1 o clock position and repeat s...

Page 28: ...is prevents lock out in the case of self locking locks ATTENTION Danger of damage to electronic components from electrostatic discharge Disassemble the outer door knob 1 Position the service tool on the inner side of the outer door knob 2 Turn the service tool clockwise and unlock the outer door knob 3 Remove the outer door knob 4 Remove the existing used battery 1 2 3 4 ...

Page 29: ... has been successful Assemble the outer door knob The outer door knob can only be attached in one position The Kaba logo and the upper surface of the battery compartment must be on the same side 6 Push the outer door knob over the door knob module 7 Attach the service tool to the outer door knob 8 Turn the service tool anticlockwise and lock it The outer door knob and the cylinder are now firmly c...

Page 30: ...ders can be individually programmed with the media on site in a manual process using the master media It is not possible to program time functions with this type of programming 7 1 1 Master media With the A master and B master media the actuators are programmed directly The B masters are organised under an A master The master media do not have any access authorisations 7 1 2 User media The user me...

Page 31: ... A structure With each B master separate access authorisations can be granted to user media A user medium can be programmed with various B masters but not with the same digital cylinder Up to 4000 user media can be programmed for each digital cylinder These can be distributed across the various B masters as wished For example a B1 master only manages 50 users whilst another master B2 manages up to...

Page 32: ...tion Confirmation Launch programming mode 1 Hold the A master medium in front of the outer door knob for approx 1 s 1 x short Program B master 2 Hold the B master medium in front of the outer door knob for approx 1 s 1 x short 3 Hold further B master media in front of the outer door knob for approx 1 s 1 x short End of programming mode 4 Hold the A master medium in front of the outer door knob for...

Page 33: ... short Programming user media 2 Hold user medium in front of outer door knob for approx 1 s 1 x short 3 Hold further user media in front of outer door knob for approx 1 s 1 x short End of programming mode 4 Hold the B master medium in front of the outer door knob for approx 1 s If no master medium is held up within 10 seconds programming mode ends automatically 1 x long 1 1 s Beep 2 1 s Beep 3 1 s...

Page 34: ...ster medium in front of the outer door knob for approx 1 s 1 x short Deleting user media 2 Hold user medium in front of outer door knob for approx 3 s 2 x short End of programming mode 3 Hold the B master medium in front of the outer door knob for approx 1 s If no master medium is held up within 10 seconds programming mode ends automatically 1 x long 1 1 s Beep 3 s 2 Beep Beep 4 Beeeep 1 s ...

Page 35: ...ster medium in front of the outer door knob for approx 1 s 1 x short Delete B master 2 Hold the B master medium in front of the outer door knob for approx 3 s 2 x short End of programming mode 3 Hold the A master medium in front of the outer door knob for approx 1 s If no master medium is held up within 10 seconds programming mode ends automatically 1 x long 1 1 s Beep 3 s 2 Beep Beep 3 Beeeep 1 s...

Page 36: ...ort A master 1 Hold the A master medium in front of the outer door knob for approx 10 s 2 x short 10 s 1 Beep Beep 10 s 1 Beep Beep All master media and user media will be deleted The traceback will be deleted Action Confirmation Restore factory settings 1 With an A B structure hold the master A medium in front of the outer door knob for approx 15 s or with a B structure do the same with the maste...

Page 37: ...wo main functions that can be executed on the digital cylinders using the programmer are write export and read import data These functions always require a valid master Data can be exported and imported wirelessly using the programmer via the radio interface or using the programming cable Export to digital cylinder In the case of export the configuration data from the programmer are written to the...

Page 38: ...raceback Configuration The existing configuration data for the digital cylinders stored on the programmer will be overwritten following confirmation 1 Press Import menu key 2 Log in to the digital cylinder using the programming master 3 Select the Configuration menu and confirm this with the ENTER key 4 The configuration of the digital cylinder will be read out and confirmed The traceback and the ...

Page 39: ...ital cylinder Check on the components and function 1 month Repair of the cam s spring mechanism required 10 years All types Kaba digital cylinder Function check as specified in user manual for the components 12 months Replacing the batteries 24 months Clock components Check and set time with the programmer 12 months WARNING For emergency exit locks in accordance with EN 179 and panic door locks in...

Page 40: ...by turning the door knob 2 Turn the inside knob of the digital cylinder clockwise until just before the upper rest area 11 o clock position 3 Hold this position in doing so it should be possible to feel the reset force 4 Press down the lever handle which should open the latch the bar and the door 5 Let go of the inside door knob the inside knob should return to the neutral area 5 7 o clock positio...

Page 41: ...ew battery ready See page 28 8 1 4 Setting the clock A programming device is necessary to set and check the clock in the digital cylinders Always check the time following a change of batteries or at least once a year The separate user manual for the programmer contains a detailed description It is essential that the clock is set precisely for the system to work correctly in CardLink authorisation ...

Page 42: ...ning with a new battery In this case insert a new battery See page 28 Emergency opening with programmer Emergency opening can also be executed using the programmer For access authorisations with time settings and CardLink always set the clock precisely after emergency opening The separate user manual for the programmer contains a detailed description of emergency opening 1 Remove outer door knob 2...

Page 43: ...edium The programmer can also be used to implement an INI reset The valid master medium is also required for this variant The separate user manual for the programmer contains a detailed description of INI reset 2 x short Tweezers with valid medium The digital cylinders have INI reset contacts A valid medium is also required for this variant 1 Remove the outer door knob 2 Rotate module so that the ...

Page 44: ...gnal Optical signal Possible causes Measures No optical or acoustic signals mechatronics is functioning correctly Signals were deactivated with the programmer Check configuration with the programmer Defect in electronics Replace the door knob module No entry with medium authorised for entry 8 x short 8 x red Mechatronic components or cam are jamming Check the function of the door knobs and the loc...

Page 45: ...echatronic components include digital cylinders for example Opening times The opening times for a digital cylinder can be selected in the programmer The time opening time for which a digital cylinder should be opened Programming master Programming masters are media with a high level of authorisation used to program lower ranking user media and modify the settings in digital cylinders Programming P...

Page 46: ...46 k1evo805en 2012 09 Kaba digital cylinder User manual Notes ...

Page 47: ...User manual Glossary Kaba digital cylinder k1evo805en 2012 09 47 ...