background image

52 SERIES

M

ODELS

 52 & T52

O

PERATING

  I

NSTRUCTIONS

The following instructions cover 

Model 52 & T52

 lock operations. The lock models

operate the same except for an additional feature that is found in the 

Model T52

 that

allows you to program a time delay for lock opening and an opening window for the lock.
After entering the proper combination(s) for the lock, the bolt cannot be retracted until the
time delay has expired. Once the delay has expired, the bolt must be retracted within the
opening window.

SUPER MASTER CONTROL

The Super Master Combination is a six-digit combination used to reset the lock to the
factory default combination (

50 25 50

) in the event the user combination(s) are lost. 

See

the Super Master Operations sheet (P/N 3001.032).

LOCK MODES

A maximum of two users can exist in a lock. A lock can operate in either 

Single Mode

 or

Dual Custody Mode

.

Note:

For a UL listed installation, only one user can be activated.

•   

Single Mode

  

E

Single Mode

 defaults to having only a 

Manager User

 (User 1) in the lock. A 

second

user

 (User 2) can then be added by the Manager User (User 1). 

 

(See section on

Manager User Operations

.)

In Single Mode only one valid user combination is required to open the lock - the Manager
User (User 1) combination or the User 2 combination.

Note:

Default lock status from the factory is Single Mode with an opening

combination of “50 25 50” for the Manager User (User 1).

   

Dual Custody Mode

  

E

 

E

Dual Custody Mode

 defaults to two users in the lock - 

User 1

 and 

User 2

.

Two user combinations are required to open the lock - the User 1 combination and the
User 2 combination.

Note:

Manager User Operations are not available in Dual Custody Mode.

Summary of Contents for 52

Page 1: ...s sheet P N 3001 032 LOCK MODES A maximum of two users can exist in a lock A lock can operate in either Single Mode or Dual Custody Mode Note For a UL listed installation only one user can be activated Single Mode E Single Mode defaults to having only a Manager User User 1 in the lock A second user User 2 can then be added by the Manager User User 1 See section on Manager User Operations In Single...

Page 2: ...he lock G R 8 8 8 8 8 2 Position the dial to cover the red bar 3 For Single Mode E E E E E Factory combination is 50 25 50 Enter Manager User User 1 or User 2 combination G 8 8 8 8 8 For Dual Custody Mode E E E E E E E E E E Enter User 1 or User 2 combination G 8 8 8 8 8 Enter the second combination G 8 8 8 8 8 Wrong Try Penalty 5 wrong tries 3 min lockout Timed only while lock is powered Each add...

Page 3: ... 8 8 8 8 For User 2 Press Press Press G 8 8 8 8 8 3 Enter current combination Factory combination is 50 25 50 G 8 8 8 8 8 4 Enter new six digit combination G 8 8 8 8 8 5 Enter new combination again for verification G R 6 Open the lock with the new combination before closing container CHANGE LOCK MODE SINGLE DUAL CUSTODY Note Changing the lock mode will reset the combination s to 50 25 50 1 For sel...

Page 4: ...t opening of the lock OPENING THE LOCK WITH TIME DELAY This feature is only available on the Model T52 lock If operating a Model T52 Lock with a Delay Time set to something other than 0 red flashes R will display after a combination has been entered and will continue during the delay while the lock is powered When the delay time expires if you are operating a self powered lock you must power 4 3th...

Page 5: ...ote User 2 is added to the lock as Enabled with a factory combination of 50 25 50 User 2 can change the User 2 combination while Enabled but only the Manager User User 1 can change the lock access status DELETE USER 2 1 For self powered lock power 4 4 4 4 4 3 3 3 3 3 the lock G R 8 8 8 8 8 2 Press Press G 8 8 8 8 8 3 Enter Manager User User 1 combination G R DISABLE USER 2 1 For self powered lock ...

Page 6: ...g the red and green LEDs The positive battery terminal should cover the red LED Enter a valid combination and open the lock while holding the battery in place 2 Locate the battery clip mounted inside the door near the lock 3 Note how the battery and the cable are positioned in the clip then remove the battery and battery cable from the battery clip 5 Unsnap the connector from the old battery and r...

Page 7: ...NOTES ...

Page 8: ...Kaba Mas Corporation 749 W Short Street Lexington KY 40508 USA Phone 859 253 4744 FAX 859 255 2655 Technical Support 800 950 4744 www kaba mas com Document Number 3002 032 Rev C 04 03 ...

Reviews: