background image

K

Q

D

E

V

E

N

P

T

A

B

R

S

U

C

M

J

L

G F

H

H

E-Plex 1500 Series

Installation Guide

for door thickness 1

3

/

8

" to 2"

PARTS LIST

A-

  Outside Housing Assembly

B-

 Gasket

C-

  Dead Bolt Assembly

D-

  Inside Trim Assembly

E-

  2 X Mounting Screws (12-24 X 1

5

/

8

”)

F-

  2 X Screws (8-32 X 

7

/

32

”)

G-

  Strike Plate

H-

  4 X Screws (8-32 X 

3

/

4

”)

J-

  Reinforcing Plate

K-

  Dust Box

L-

  2 X Wood Screws 3” Long

M-

  Tail Piece

N-

  Inside Cover

P-

  Screw (6-32 X 

3

/

4

”, Flat Head)

Q-

  Cylinder Cap

R-

  Key (may be shipped separately)

S-

  3 Batteries “AA”

T-

  Key Cylinder (may be shipped separately)

U-

  2 X Screw (6-32 X 

3

/

4

”, Pan Head)

V-

  1 X Split Lock Washer

PARTS LIST

Right Hand (RH)

Left Hand (LH)

TOOLS REQUIRED

KEY OVERRIDE CYLINDER – 

If cylinder is not already assembled in the lock, proceed as follow:

ADJUST LOCK HANDING ON OUTSIDE HOUSING ASSEMBLY "A"

ASSEMBLE TAIL PIECE

REMOVE 

INSIDE COVER

 INSTALL INSIDE COVER

INSTALL STRIKE ON WOOD FRAME

 INSTALL STRIKE ON STEEL FRAME

STATES OF THE LOCK

SEQUENCE OF OPERATIONS FOR START-UP PROGRAMMING 

GENERAL PROCEDURE FOR PUSHBUTTON PROGRAMMING

ASSEMBLE OUTSIDE HOUSING

 INSTALL INSIDE TRIM 

ASSEMBLY

WARNING

WARNING

WARNING

•  Safety Glasses
• 

1

/

2

" (13mm) Chisel

• 

1

/

8

" (3mm) Drill Bit

• 

5

/

32

" (4mm) Drill Bit

• 

1

/

2

" (13mm) Drill Bit

•  1" Drill Bit or Hole Saw
• 2

1

/

8

" (54mm) Hole Saw

• Drill
•  Awl or Center Punch
•  Small Screwdriver ( 

1

/

8

" approx.)

•  Phillips Screwdriver (#2)
•  Adjustable Square
•  Tape Measure

1- Please read and follow all directions carefully.
2-  Carefully inspect glass, door frame, door etc... to ensure that the 

recommended procedures will not cause damage. Kaba Ilco standard 

warranty does not cover damages caused by installation.

3- Wear safety glasses when making the holes.
4- All the following operations and testing of the lock to be done with 

    door open.

1. Remove 4 screws
2. Remove back plate

Clearance

Override 
Switch

Ring 

opening far 

from slot

1

2

3

U

V

E

Install in door stop side

Door 

stop

Remove tape

IMPORTANT:

 To be tightened very well

Install:

- U fire rated steel doors

- V under bottom screw E

- Batteries after tightening 2 screws E

Click in place

Note:

 

For maximum 

security install 

reinforcing plate

!

!

!

LOCK DIAGRAM

4

5

6

7

8

9

10

11

12

13

14

15

INSTALL DEADBOLT IN DOOR

DOOR PREPARATION

NOTE:

  Drill from both sides of the door to 

prevent unsightly damage.

1.   Determine which template fits your 

E1500 lock installation, either 2

3

/

8

(60mm) or 2

3

/

4

" (70mm) backset. See 

note 2 on drilling template

2.   Place appropriate template (supplied) 

onto door and mark holes.

3.   Drill holes as per dimensions on the 

template. The 1" (25mm) hole to be on 

the center line of door thickness.

4.   Mortise door edge for dead bolt face 

plate.

2

3

/

8

" (60mm)  or  2

3

/

4

" (70mm)

1"(25mm)  

Diameter 

Hole Saw

2

1

/

8

" (54mm) 

Diameter 

Hole Saw

Do not 

remove 

tape

Slot  

at the  

bottom

Center

Line

1

3

1

2

3

2. ADJUST BACKSET 

    OF DEADBOLT

 Do not remove tape.
The deadbolt is pre-set 

as 2

3

/

4

" (70mm) backset. 

Proceed as illustrated to 

change to 2

3

/

8

" (60mm) 

backset, if required.

2

3. Install Key Cylinder

4.  Watch for wires not to be pinched when re-

installing back plate

5.  Re-assemble back plate using screws as 

shown

Groove at 

6:00 o'clock

Groove at 

12:00 o'clock

Rotate to change 

from RH to LH

Hold from 

rotating

Factory Mode
The factory mode is one of three primary states of the E-Plex Lock.  The main characteristics of this state are:
 

•  The E-Plex Lock opens only when the 8-digit default master combination (1-2-3-4-5-6-7-8) is keyed in. 

 

•  The visual indication for ‘access granted’ is green LED flashing once.  A high-pitched tone is also generated while the green LED is on.

 

•  The Master User must change the Master Code to be able to exit the factory mode, and switch to the access mode or pushbutton programming mode.

Access Mode
This mode refers to a lock that is operational for user access, and not in factory or Programming Mode.

Pushbutton Programming Mode
The E-Plex lock enters the Pushbutton Programming Mode when the user enters the master combination or one of the manager combinations, preceded and followed by the 
character ‘#’ (ex: #12345678#). Once the E-Plex Lock is in the Pushbutton Programming Mode, the Master/Manager can enter one or more command sequences. Each command 
sequence ends with a ‘#’ character that acts like an <

enter> character. At the very end of all sequences of programming commands, enter one more # to remove the lock from the 

Pushbutton Programming Mode to return to normal access mode.

What is the recommended sequence of operations?
With the E-Plex Lock in the factory mode.
 

•   Program the Access Code Length (default length is four digits). The access 

code field length can only be changed when the lock is not activated (when 
still in the factory mode).

 

•   Change factory Master to your own Master Code (always eight digits) to 

place lock in access mode.

Put lock in Pushbutton Programming Mode.
 

• Set the Date / Time

 

• Program the Lock ID and Unlock time

 

• Program the Lock for the Duration of Passage Mode (if desired)

 

• Program the Lock for Tamper Time Settings

 

• Program the Lock for Buzzer Volume

 

• Add Access Codes as desired

  a. Put the lock in Programming Mode by pressing # Master Code #
  b.  Use the Summary of Commands Table (Section 16) of this guide to enter the 

three digit command sequence (Command Type + Function Code), followed by #.

  c. Enter the appropriate numbers as required.
  d. Press # to end Programming Mode.
  e.  Once the lock is in programming mode, multiple command  sequences can be 

entered without having to repeat the #mastercode#. However, if there is no activity 

for 15 seconds at the keypad, the lock will automatically exit from programming mode.

LIT1054 0913