E-Plex 1500 Series
Installation Guide
for door thickness 1
3
/
8
" to 2"
PARTS LIST
A-
Outside Housing Assembly
B-
Gasket
C-
Dead Bolt Assembly
D-
Inside Trim Assembly
E-
2 X Mounting Screws (12-24 X 1
5
/
8
”)
F-
2 X Screws (8-32 X
7
/
32
”)
G-
Strike Plate
H-
4 X Screws (8-32 X
3
/
4
”)
J-
Reinforcing Plate
K-
Dust Box
L-
2 X Wood Screws 3” Long
M-
Tail Piece
N-
Inside Cover
P-
Screw (6-32 X
3
/
4
”, Flat Head)
Q-
Cylinder Cap
R-
Key (may be shipped separately)
S-
3 Batteries “AA”
T-
Key Cylinder (may be shipped separately)
U-
2 X Screw (6-32 X
3
/
4
”, Pan Head)
V-
1 X Split Lock Washer
PARTS LIST
Right Hand (RH)
Left Hand (LH)
TOOLS REQUIRED
KEY OVERRIDE CYLINDER –
If cylinder is not already assembled in the lock, proceed as follow:
ADJUST LOCK HANDING ON OUTSIDE HOUSING ASSEMBLY "A"
ASSEMBLE TAIL PIECE
REMOVE
INSIDE COVER
INSTALL INSIDE COVER
INSTALL STRIKE ON WOOD FRAME
INSTALL STRIKE ON STEEL FRAME
STATES OF THE LOCK
SEQUENCE OF OPERATIONS FOR START-UP PROGRAMMING
GENERAL PROCEDURE FOR PUSHBUTTON PROGRAMMING
ASSEMBLE OUTSIDE HOUSING
INSTALL INSIDE TRIM
ASSEMBLY
WARNING
WARNING
WARNING
• Safety Glasses
•
1
/
2
" (13mm) Chisel
•
1
/
8
" (3mm) Drill Bit
•
5
/
32
" (4mm) Drill Bit
•
1
/
2
" (13mm) Drill Bit
• 1" Drill Bit or Hole Saw
• 2
1
/
8
" (54mm) Hole Saw
• Drill
• Awl or Center Punch
• Small Screwdriver (
1
/
8
" approx.)
• Phillips Screwdriver (#2)
• Adjustable Square
• Tape Measure
1- Please read and follow all directions carefully.
2- Carefully inspect glass, door frame, door etc... to ensure that the
recommended procedures will not cause damage. Kaba Ilco standard
warranty does not cover damages caused by installation.
3- Wear safety glasses when making the holes.
4- All the following operations and testing of the lock to be done with
door open.
1. Remove 4 screws
2. Remove back plate
Clearance
Override
Switch
Ring
opening far
from slot
1
2
3
U
V
E
Install in door stop side
Door
stop
Remove tape
IMPORTANT:
To be tightened very well
Install:
- U fire rated steel doors
- V under bottom screw E
- Batteries after tightening 2 screws E
Click in place
Note:
For maximum
security install
reinforcing plate
!
!
!
LOCK DIAGRAM
4
5
6
7
8
9
10
11
12
13
14
15
INSTALL DEADBOLT IN DOOR
DOOR PREPARATION
NOTE:
Drill from both sides of the door to
prevent unsightly damage.
1. Determine which template fits your
E1500 lock installation, either 2
3
/
8
"
(60mm) or 2
3
/
4
" (70mm) backset. See
note 2 on drilling template
2. Place appropriate template (supplied)
onto door and mark holes.
3. Drill holes as per dimensions on the
template. The 1" (25mm) hole to be on
the center line of door thickness.
4. Mortise door edge for dead bolt face
plate.
2
3
/
8
" (60mm) or 2
3
/
4
" (70mm)
1"(25mm)
Diameter
Hole Saw
2
1
/
8
" (54mm)
Diameter
Hole Saw
Do not
remove
tape
Slot
at the
bottom
Center
Line
1
3
1
2
3
2. ADJUST BACKSET
OF DEADBOLT
Do not remove tape.
The deadbolt is pre-set
as 2
3
/
4
" (70mm) backset.
Proceed as illustrated to
change to 2
3
/
8
" (60mm)
backset, if required.
2
3. Install Key Cylinder
4. Watch for wires not to be pinched when re-
installing back plate
5. Re-assemble back plate using screws as
shown
Groove at
6:00 o'clock
Groove at
12:00 o'clock
Rotate to change
from RH to LH
Hold from
rotating
Factory Mode
The factory mode is one of three primary states of the E-Plex Lock. The main characteristics of this state are:
• The E-Plex Lock opens only when the 8-digit default master combination (1-2-3-4-5-6-7-8) is keyed in.
• The visual indication for ‘access granted’ is green LED flashing once. A high-pitched tone is also generated while the green LED is on.
• The Master User must change the Master Code to be able to exit the factory mode, and switch to the access mode or pushbutton programming mode.
Access Mode
This mode refers to a lock that is operational for user access, and not in factory or Programming Mode.
Pushbutton Programming Mode
The E-Plex lock enters the Pushbutton Programming Mode when the user enters the master combination or one of the manager combinations, preceded and followed by the
character ‘#’ (ex: #12345678#). Once the E-Plex Lock is in the Pushbutton Programming Mode, the Master/Manager can enter one or more command sequences. Each command
sequence ends with a ‘#’ character that acts like an <
enter> character. At the very end of all sequences of programming commands, enter one more # to remove the lock from the
Pushbutton Programming Mode to return to normal access mode.
What is the recommended sequence of operations?
With the E-Plex Lock in the factory mode.
• Program the Access Code Length (default length is four digits). The access
code field length can only be changed when the lock is not activated (when
still in the factory mode).
• Change factory Master to your own Master Code (always eight digits) to
place lock in access mode.
Put lock in Pushbutton Programming Mode.
• Set the Date / Time
• Program the Lock ID and Unlock time
• Program the Lock for the Duration of Passage Mode (if desired)
• Program the Lock for Tamper Time Settings
• Program the Lock for Buzzer Volume
• Add Access Codes as desired
a. Put the lock in Programming Mode by pressing # Master Code #
b. Use the Summary of Commands Table (Section 16) of this guide to enter the
three digit command sequence (Command Type + Function Code), followed by #.
c. Enter the appropriate numbers as required.
d. Press # to end Programming Mode.
e. Once the lock is in programming mode, multiple command sequences can be
entered without having to repeat the #mastercode#. However, if there is no activity
for 15 seconds at the keypad, the lock will automatically exit from programming mode.