background image

INSTALLATION GUIDE

ILCO Q90 RFID 

(Quantum Series)

PK3656

Summary of Contents for ILCO Q90 RFID

Page 1: ...INSTALLATION GUIDE ILCO Q90 RFID Quantum Series PK3656 ...

Page 2: ...bstitute parts will result in poor performance of the lock Proximity Reader Assembly Mortise Scalp Plate Outside Lever Trim Screw Pack Strike Plate Inside Trim Assembly All information contained herein including but not limited to product pricing and other intellectual property is confidential and intended for the sole use of the addressee s so named Any misuse of this confidential information con...

Page 3: ...0 mortise lock Drill fixture If you are using a Q90 drill fixture position and clamp the fixture on the door The fixture has two positioning posts that rest inside the mortise establishing the proper backset for the trim When the fixture is clamped its surfaces should be parallel with the door surfaces and door edges Not all holes go through the door refer to the template Notch the material on the...

Page 4: ...ortise front plate to the door using the two mortise screws 12 x 1 1 4 screws for wood doors 12 24 x 3 8 screws for metal doors Be sure that the screws are fully tightened Important DO NOT leave the screws loose The screws must be fully tightened before the trim is installed If you must leave the mortise loose to install the trim the door preparation is incorrect 5 Install the scalp plates with th...

Page 5: ...NECTOR 3 Position the inside trim on the inside of the door 4 Secure inside trim to the proximity card reader assembly to the inside trim using three 8 32 x 1 1 4 screws Important Do not fully tighten the screws at this point 5 Align the outside lever trim with the diagonal holes located on either side of the mortise hub and secure it using the remaining two 8 32 x 1 1 4 screws see Fig 4 Important...

Page 6: ...should be at the top bottom 12 00 and 6 00 position when the mortise dead bolt is retracted see Fig 6 The retaining ring should rest on the switch cam when fully inserted the proper positioning of the cam will allow the door to be opened when the dead bolt is retracted and block entry when the dead bolt is thrown for privacy except when emergency keycards are used Important As illustrated in figur...

Page 7: ...k as indicated in the following section and in the programming manual before closing the door When the installation keycard is used the green and red LEDs will blink together then the green LED will blink once indicating that the lock s time and date are not set 15 For humid outdoor environments apply dielectric grease inside the USB connector after programming to guard against corrosion from pers...

Page 8: ...set use the Q90 RFID LPI probe to reset 30 seconds This will be done during programming or using the FDU to reset the time Red LED flashes 12 times Dead bolt is thrown or switch cam is not properly aligned No light Keycard not allowed OR keycard cancelled by new keycard Red and green LEDs flash Low battery contact the ILCO service department 8 times use staff Must alternately or emergency keycard ...

Page 9: ...hes once when a valid guest card is presented while privacy is enabled Access is denied The red LED flashes 8 times when a staff card is presented while privacy is enabled Access is granted Door function Door closes and latches with little or no interference Dead bolt extends fully through the strike plate without interference door closed Spacing between door edge and inside door jamb does not exc...

Page 10: ... 1 514 735 5410 General Information www kabalodging com Online Consumable Orders www ilcostore com To access all of our easy steps please visit our Support Website www ilcosupport com Kaba Ilco Inc reserves the right to modify the characteristics and features of all products in this publication Kaba Ilco Inc 2014 all rights reserved ...

Reviews: