Dual-Handed Swingbolt or Deadbolt Lock Instructions
MANAGER GUIDE
Suggested Keypad
STANDARD FEATURES
Manager Mode
• Open Lock
• Activate/Delete Users
• Enable/Disable Users
• Set Time Delay Values
User Code
• Open Lock
• Change Code
Wrong Try Penalty
• Four (4) consecutive invalid codes initiates five minute
delay period.
Low Battery Warning
• Repeated audio and visual signal (LED flashing and
repeated beeping) during opening indicates battery low.
Audio and Visual Signal
• Double signal (LED flashes and unit beeps) indicates entry
is valid or accepted.
• Triple signal indicates invalid or not accepted.
Audit Trail
• On board non volatile memory records up to 63 last
events, including user ID and action.
PROGRAMMABLE FEATURES
ACTIVE
Code length
______________
(from 6 to 9 digits)
Multiple Users
1
2
3
4
5
6
7
8
9
£ £ £ £ £ £ £ £ £
Time Delay
• Delay period 1 - 99 minutes
______________
• Open period 1 - 19 minutes
______________
Time Delay Override
£
• Ability to add second combination to override delay period
Dual Code
£
• Two codes required to open
Silent Signal Alarm
(Optional Alarm Box Required)
£
• Duress signal if last number of code(s) is entered using
one number higher or one number lower.
Signal to Disable Lock Opening
£
(Optional Alarm Box Required)
• Input signal disables opening of lock by valid code
Signal to Disable Lock
(Optional Alarm Box Required)
£
• Input signal disables all lock functions by valid code
3750-K
Round Entry
Lock Choices
Dual-Handed Swingbolt
• All locks are shipped from the factory in Pre
Set-up mode, with no features installed.
• Lock will open when 1 is pressed.
• Please follow ComboGard Pro setup
instructions (P/N 731.018) to initially configure
locks settings.
OPENING THE LOCK
1.
Enter valid Manager or User code.
2.
The unit will indicate a valid code entry with a
double signal.
3.
Within four (4) seconds open lock by either rotating
the keypad to open position (clock-wise) or turning
the handle to the open position.
4.
Pull door open.
• Invalid Code Entry
- Unit will signal three (3) times.
CHANGING CODE
ALWAYS PERFORM THIS OPERATION WITH THE
DOOR OPEN
Each code must be changed independently.
1.
Enter existing code and hold down the last digit
until unit double signals twice and the LED
stays on.
2.
Press the “0” key.
3.
Enter your NEW code, then re-enter NEW code
to confirm.
4.
If a mistake is made wait thirty (30) seconds and
repeat steps
1
-
3
.
5.
Test unit operation several times before closing
the door.
• Valid Code Entry
- Double signal after valid code
is entered.
• Invalid Code Entry
- Triple signal and old code
is still valid.
ACTIVATING USER
ALWAYS PERFORM THIS OPERATION WITH THE
DOOR OPEN
1.
Enter Manager code and hold down last digit of
code until unit double signals twice and the LED
stays on.
2.
PRESS 1. Unit signals twice.
3.
Press User number, 1 to 9. Unit signals twice.
4.
Enter NEW code, then re-enter NEW code
to confirm.
5.
If a mistake is made wait thirty (30) seconds and
repeat steps
1
-
4
.
• Valid Code Entry
- Double signal after valid code
is entered.
• Invalid Code Entry
- Triple signal and old code is
still valid.
Deadbolt
© copyright 2008
(P/N) 732.018
(Manager)
LA GARD - A Member of the Kaba Group