background image

Condition

Parameters

Green LED

Red LED

Duration

Rate

Valid pushbutton

ON

OFF

1/10 sec

Once

pressed
Timeout expired

OFF

ON

1 sec; A

Once

Valid access

ON

OFF

1 sec

Once

code keyed
Access granted

ON

OFF

1/10 sec

1 sec

Access granted

ON 

ON

1/10 sec

1 sec

(battery low condition)
Access denied

OFF

ON

1 sec; A

Once; B

Valid programming

ON

OFF

1 sec

Once

entry
Invalid programming

OFF

ON

1 sec; A

Once; B

entry (including 

duplicate access code)
Tamper shutdown

OFF

ON

2 sec

Once

beginning
Tamper shutdown state

OFF

ON

1 sec; C

10 sec

Tamper shutdown

ON

OFF

2 sec; C

Once

ending

Visual Feedback Message Definitions

Summary of Pushbutton Programming Commands
Name
Diagnostic

Command
500 #

123456789*0#

Description of Command
‘Manual diagnostic’

www.kabaaccess.com

Quick

Reference

Guide

PKG3172 0313

For PowerPlex 2000 only:

Lock is ready when front

ON

OFF

1/10 sec

Once

lever is depressed
Lock’s stored power is

OFF

ON

1/10 sec

1 sec

starting to fade

A

= 1/10 second;  B = Twice;  C = Can be observed only when you pump the lock’s lever

E2000 Operation:

Enter your valid PIN to Access the lock and/or to program the

lock at its keypad.

PowerPlex 2000 Operation:

This model is a self-powered lock.  To access and/or

program the lock, you must first generate power by depressing the front lock

lever down at least once. This energizes the lock temporarily for a few seconds ,

enough time for you to enter your PIN and open the lock, or start to program the

lock with a command sequence. 

Name
Configur

Command
000 #
MMMMMMMM#

MMMMMMMM#

004 #

TT#

005 #

TT#

006 #

TT#

007 #

TT#

008 #

VV#

009 #

LL#

099 #

Description of Command
‘Modify Master User Access Code (lock’s 

activation)’ (Always 8 digits)

‘Unlock time setup’ (TT = 02 to 20 seconds)

‘Passage Mode Timeout setup’ (TT = 01 to 24

hours - duration time in hours; 00 = no time limit)

Note: Not applicable to PowerPlex 2000 models 

‘Tamper time setup’ (TT = 00 to 90 seconds)

‘Tamper wrong try setup’ (TT = 03 to 09)

‘Buzzer volume control’ (VV = 00 to 03; 00 = off; 

01 = Low; 02 = Normal; 03 = High)

‘Modify access length’ (LL = 04 to 08 digits)

‘Reset to factory default values’, except access

code length. (Master, manager and access user 

are retained if already programmed.)

Summary of Pushbutton Programming Commands

To begin, put lock in programming mode by pressing: #Master Code#

2000 Series

Series

Reviews: