QUICK REFERENCE GUIDE

 X-09

Note:

If at any time the dial remains stationary

for more than 40 seconds, the lock will reset
(LCD will go blank) requiring the operator to redial
the entire combination or restart the operation.

OPEN THE LOCK

(Factory Combination = 50-25-50)
Single Combination Mode:

1.

Dial 

left

 until lock is “powered”.

2.

Continue dialing 

left

 to first number of

combination.

 

Stop

3.

Dial 

right

 to second number of combination.

Stop

4.

Dial 

left

 to third number of combination. Stop.

5.

Dial 

right

. After 

OP

 with a right arrow is

displayed, continue dialing right to retract
bolt.

Dual Combination Mode

:

First Operator

1.

Dial the first combination as in Single Mode.

2.

Dial 

right

 until 

C2

 is displayed.

Second Operator

3.

Within 40 seconds dial 

left

 to first number of

the second combination. 

 

Stop

4.

Dial 

right

 to second number of combination.

Stop

5.

Dial 

left

 to third number of combination. Stop.

6.

Dial 

right

. After 

OP

 with a right arrow is

displayed, continue dialing right to retract
bolt.

Supervisory/Subordinate Mode

:

• 

To Unlock  (UL)

To enable lock access for the Subordinate
combination, dial the Supervisor combination as if
dialing the combination to open the lock. Then dial

right

 and 

UL

 will appear on the display. Once the

lock is in an Unlocked status, the Subordinate
combination can be used to open the lock at any
time.
• 

To Lock Up  (LU)

To disable lock access for the Subordinate
combination, reenter the Supervisor combination.
Then dial 

right

 and 

LU

 will display and the

Subordinate combination will no longer open the
lock.

SET OPERATING MODE and CHANGE
COMBINATION(s):

1.

Open the lock and retract the bolt to open
container if not already open.

Note:

If using the serial number method,

simply dial an incorrect combination to get a
lightning bolt.

2.

Insert Change Key into back of lock.

3.

Release container locking bolts if necessary.

4.

Dial 

left

 until lock is “powered”. The Change

Key symbol will be displayed.

5.

Dial 

left-right-left

 to dial the current

combination(s).

Note:

If using the serial number method, dial

the serial number at this time.

6.

Dial 

right

 until 

SL

 is displayed.

7.

Dial 

left

 to select the mode of operation:

1

-Single Mode,  

2

-Dual Mode, or

3

-Super/Sub Mode

Once the mode is selected, pause briefly.

If selection 1, Single Combination Mode:

8.

Dial 

right

 until 

EC

 appears.

9.

Dial 

left-right-left

 to dial the 

new combina-

tion

 as if dialing the combination to open the

lock.

10. Dial 

right

 briskly. The new combination will

be displayed two times, two digits at a time,
followed by 

PO

.

11. Pull Out change key.  

CC

 will appear.

12. Dial 

left-right-left

 to dial 

new combination

again for confirmation. Once 

OP

 with a right

arrow is displayed, continue dialing right to
retract the bolt.
The new combination is now set.

If selection 2 or 3, Dual or Super/Sub Mode:

8.

Dial 

right

 until 

C1

 appears.

9.

Dial 

left-right-left

 to dial the 

first new

combination

 (Supervisory if Super/Sub

Mode) as if dialing the combination to open
the lock.

10. Dial 

right

 briskly. The new combination will

be displayed two times, two digits at a time,
followed by 

PO

.

11. Dial 

right

 until 

C2

 appears.

12.   Dial 

left-right-left

 to dial the 

second new

combination

 (Subordinate if Super/Sub

Mode) as if dialing the combination to open
the lock.

13. Dial 

right

 briskly. The new combination will

be displayed two times, two digits at a time,
followed by 

PO

.

14. Pull Out change key.  

CC

 will appear.

15. Dial the 

new combinations

 once again for

confirmation.
The new combinations are now set.

IF YOU LOCK THE CHANGE KEY IN THE
SAFE

Note:

 

 You cannot use the serial number

in place of the combination for this
procedure. The combination must be
known.

1.      Allow lock to power down. (After 40 seconds,

the display will go blank. Wait an additional 2
minutes for full power down.)

2.      Dial 

right

 (CW) until lock is “powered” and the

number of successful openings is flashing.

Caution:

 

 Do not continue to dial right

once you see the flashing numbers on
the display.

3.      Now dial the current combination(s) just as

you would to open the lock ; i.e., 

left 

(CCW) to

dial the first number, 

right

 (CW) to dial the

second number, 

left

 (CCW) to dial the third

number.

4.    Dial 

right

 (CW). After 

OP

 with a right arrow

(

OP

en right) is displayed, continue dialing to

the right to retract the lock bolt.

You may now restart the procedure to Set
the Operating Mode and Change
Combination(s).

CLOSE / RELOCK CONTAINER

1.

Close container door.

2.

Turn dial 

left

 a minimum of one complete

revolution to extend the bolt.

3.

Turn dial 

right

 a minimum of one complete

revolution to ensure it is locked.

Note:

The Dial should turn freely in

either direction without catching or binding
when the bolt is extended and the
container is locked.

CHECK # OF SUCCESSFUL OPENINGS

1.      Allow lock to power down. (After 40 seconds,

the display will go blank. Wait an additional 2
minutes for full power down.)

2.

Dial 

continuously 

to the

 right

 to display the

total number of successful openings (two
digits at a time).

CHECK # OF UNSUCCESSFUL AT-
TEMPTS

1.      Allow lock to power down. (After 40 seconds,

the display will go blank. Wait an additional 2
minutes for full power down.)

2.

Dial 

left

 until lock is “powered”. If 3 or more

consecutive unsuccessful attempts have
occurred, a lightning bolt along with the two-
digit count will be displayed.

Document Number 522.021  Rev. C  06/03