background image

www.kahnclimatecontrol.co.uk

 Thank’s for choosing Kahn. Please read this user handbook carefully prior to 

Incorrect use may cause fire, electric shock and the unit falling may result in 

injury or leakage. Contact our designated Kahn service centre on 0333 222 4016 

specialists. The manufacturer shall not assume responsibility for accidents or injury 

caused by incorrect use.

 

This product must not be disposed together with the domestic waste. 

This product has to be disposed at an authorised place for recycling 

of electrical and electronic appliances.

Kahn Climate Control 

ATOM 

user handbook

installing and keep it for further reference.

 Thank’s for choosing Kahn. Please read this user handbook carefully prior to 

Incorrect use may cause fire, electric shock and the unit falling may result in 

injury or leakage. Contact our designated Kahn service centre on 0333 222 4016 

specialists. The manufacturer shall not assume responsibility for accidents or injury 

caused by incorrect use.

 

This product must not be disposed together with the domestic waste. 

This product has to be disposed at an authorised place for recycling 

of electrical and electronic appliances.

Kahn Climate Control 

ATOM 

user handbook

installing and keep it for further reference.

Summary of Contents for ATOM

Page 1: ...e centre on 0333 222 4016 specialists The manufacturer shall not assume responsibility for accidents or injury caused by incorrect use This product must not be disposed together with the domestic wast...

Page 2: ...R O O D N I O Attention Indoor Unit Outdoor Unit Front view To mount install the outdoor unit indoors the optional Plenum box MUST be used The maximum length of the connecting pipe if rubber is 9m The...

Page 3: ...or unit Keep at least 1m away from any electrical appliances Do not restrict air flow to the outdoor unit The indoor unit should be floor standing or suspended by its hanging brackets Mains power feed...

Page 4: ...ne as per corresponding number on the wiring terminal board Note If any of the wires are to be replaced or extended be sure to use identical diameter Please refer to the wiring diagram located on the...

Page 5: ...ctive fixing clips before tightening the screws Earth wire must be connected firmly 3 Replace the wiring terminal covering plate and secure firmly with mounting screws Installation of the Outdoor Unit...

Page 6: ...sed at where the pipe contacts the wall NOTE Installation of the drain hose 3 4 Drain hose Gas pipe Liquid pipe Felt Insulation underlay Arrangement of the drain hose To drain the condensate water eas...

Page 7: ...door unit this will reveal an allen key connection on both valves Turning anticlockwise first half unscew the small liquid port valve you will hear refrigerant gas passing through the small pipe this...

Page 8: ...8 9 FUNCTION SET TEMP SET FAN SET MODE SET LUX SET TIME UNIT OFF Kahn hardwired controller guide UNIT ON NIGHT DAY NIGHT DAY SET SET 900 UP TO 100 H M L H M L NIGHT DAY FAN HEAT COOL FAN HEAT COOL 0...