CENTRAL HEATING BOILER 

ON SOLID FUEL 

 

KALVIS-2-16,  2-25,  2-30,  2-40 

 

 

 

USERS INSTALLATION  

AND OPERATION MANUAL 

 
 

 

 

 

 

 

CERTIFICATE NO. SPSC-5199 

 

 

 

 

Summary of Contents for K-2-16

Page 1: ...CENTRAL HEATING BOILER ON SOLID FUEL KALVIS 2 16 2 25 2 30 2 40 USERS INSTALLATION AND OPERATION MANUAL CERTIFICATE NO SPSC 5199...

Page 2: ...2...

Page 3: ...without them devices not included 1 fig 1 Air supply damper 2 Service doors 3 Cast iron doors 4 smoke exhaust channel 5 Fuel loadinjg doors 6 Thermometer 7 Draught adjuster 8 Top loading cover 9 Elec...

Page 4: ...mm 290 x 290 290 x 290 290 x 390 290 x 490 Overall dimensions mm Hg H Bg B Lg L 1380 1300 760 600 1060 800 1500 1420 590 490 1220 960 1500 1420 690 590 1230 970 1500 1420 790 690 1230 970 Branching d...

Page 5: ...re is an insufficient draught it is recommended to remove turbulators Electric heating devices are automatically switched on when boiler runs out of fuel and temperature falls beneath the preset waiti...

Page 6: ...4 2 Requirements for chimney Chimney design and boiler connections into it are shown on the fig 2 and 3 Boiler sold Company Sales date Address Phone Boiler mounted Company Address Phone Foreman name l...

Page 7: ...al elbow it s cross section has to be not less than that of the boiler smoke pipe and bending radii not less than 100mm Pipe from the smoke pipe to chimney has to be not longer than 1 5 m and lean upw...

Page 8: ...value is similar 1 kg of coal gives 2 3 times more heat than 1 kg of wood Combustion of 1 kg of wood requires 4 5 m3 of air coal around 10 m3 The more ash is left the worse fuel is Energy radiation f...

Page 9: ...se hot or return water valves when boiler is operated Store dry fuels or other combustible materials close to or on top of the boiler Store fuel closer than 500 mm to boiler Ignition fuel with combust...

Page 10: ...l ventilated Recommenmded fuel humidity not greater than15 20 Attention If the boiler combusts humid wood or saw dust condensate will form acids which will shorten the life span of the boiler several...

Page 11: ...waste and ignite it In case of coal combustion 5 10 kg of firewood should be covered by a 10 cm layer of coal Secondary air dampers p 18 should be closed Dampers are operated when tmeperature in the b...

Page 12: ...uld be removed It is necessary to mount the protection valve that keeps the operating pressure in the system not greater than 0 15 MPa 1 5 kgf cm2 Notice To avoid appearance of the condensate which ma...