background image

Karel MS224

T e l e p h o n e

S y s t e m

Installation

&

Maintenance

Guide

Edition 3.2

Summary of Contents for MS224

Page 1: ...Karel MS224 T e l e p h o n e S y s t e m Installation Maintenance Guide Edition 3 2...

Page 2: ...LT48 H DSS80 DSS40 22 II 1 A OP48 H CONSOLE 22 II 1 B LT48 H FEATURE PHONE 23 II 1 C DSS80 DIRECT STATION SELECT MODULE 24 II 1 D DSS40 DIRECT STATION SELECT MODULE 25 II 2 SERIAL INTERFACE CM224 PK22...

Page 3: ...NSTALLATION 53 III 1 CONSOLES FEATURE PHONES DIRECT STATION SELECT MODULES 53 III 2 SERIAL INTERFACE 58 III 2 A PC INTERFACE 58 III 2 B SERIAL PRINTER INTERFACE 59 III 3 DOORPHONE 60 III 4 EXTERNAL AN...

Page 4: ...rence The system outline is given and all the accessories are described Brief information about the software structure of the system is presented and finally the technical specifications of the system...

Page 5: ......

Page 6: ...including a metal power rack a power card and a ring transformer BPL224 Backplane CPU224 Central Processing Module MS224 EX1 4 12 Expansion Module that can support the minimum capacity of 4 12 The MS2...

Page 7: ...cabinet provides a strong shell and a natural electromagnetic shield for the system I 1 PARTS LIST In order to make the reader familiar with the cabinet which has a complex structure the parts list f...

Page 8: ...ation Maintenance Guide Edition 3 2 5 Figure A 3 A CABINET Metal Parts 1 Front Cover 1a Power Info Panel 2 Top Cover 3 Bottom Cover 4 Wall Mount Bar 5 Rack 5a Bottom Front Part 5b Top Front Part 5b1 S...

Page 9: ...2 EX2 Connection Card H CBL 16 16 Pair MDF Cable I Mains Cable I 2 BACKPLANE OF THE SYSTEM BPL224 The backbone of MS224 system is the BPL224 Backplane All the modules which are SPS224 CPU224 MS224 EX1...

Page 10: ...is 0 4 kg I 3 POWER TO THE SYSTEM MS224 system receives 220 VAC from the mains Inside the mains fuse slot on SPS128 Power Supply Module there exist two T type fuses for mains one on phase and the oth...

Page 11: ...ened The mains transformer is located on the SPS224CR Power Card SPS224 is a Switched Mode Power Supply SMPS operating at mains voltage Receiving 220 VAC over the mains SPS224CR generates 5 VDC 5 VDC...

Page 12: ...tart until the battery voltage is above 23 VDC So preventing full discharge of the battery SPS224 makes the lifetime of the battery longer The Power Status LEDs on the front panel of the SPS224 Power...

Page 13: ...at cable called MS224 CPU FC See Figure A 6 for the outlook of MS224 CPUKON card There exists a plastic card cover in front of MS224 CPUKON card which is fixed to the top and bottom front parts of the...

Page 14: ...24 Backplane to the MS224 EX1 and MS224 EX2 Expansion Modules The pin out of the CPU224 BPL224 connector on BPL224 Backplane is as follows CPU224 BPL224 Connector Pin Signal Pin Signal Pin Signal Pin...

Page 15: ...he pin out of the MS224 CPU FC Flat Cable MS224 CPU FC Cable PIN SIGNAL PIN SIGNAL PIN SIGNAL 1 red XREL2 10 INP1 19 CTS 2 XREL1 11 OUT1 20 12V 3 MUS1 12 111A 21 OUT2 4 VAG2 13 24V 22 CM_TXD 5 DIA 14...

Page 16: ...es are used to increase the system capacity MS224 EX1 Expansion Module has a capacity of 4 12 whereas MS224 EX2 Expansion Module has a capacity of 0 16 The system should have at least one MS224 EX1 mo...

Page 17: ...EX1 and EX2 Expansion Boards respectively CON1 and CON2 Connection Cards are the interface boards between the extension telephones external lines and the MS224 EX1B and EX2B cards respectively CON1 an...

Page 18: ...such a way that the two 20 pin connectors on component side of CON1 are attached to the corresponding connectors on the component side of MS224 EX1B The same also applies to the connection of CON2 and...

Page 19: ...B6B 6 TRK6A 16 TRK6B 7 SUB7A 17 SUB7B 7 TRK7A 17 TRK7B 8 SUB8A 18 SUB8B 8 TRK8A 18 TRK8B 9 LED1 19 LED2 9 19 10 20 10 20 GND CON2 MS224 EX2B Connector K2 Signal K2 Signal K3 Signal K3 Signal 1 SUB1A 1...

Page 20: ...NG 54 X2 78 VAG 7 CONT2 31 GND 55 X27 79 8 B 32 24 VDC 56 X24 80 5 VPU 9 DA1 33 12 VDC 57 X22 81 10 DA2 34 5 VDC 58 X28 82 11 A 35 A0 59 X19 83 GNDCPU 12 C 36 A1 60 X17 84 X15 13 SUB1A 37 A2 61 5VDC 8...

Page 21: ...gure A 10 Figure A 11 The dimensions of the MS224 EX1B are 24 5 cm x 25 5 cm and the weight is 0 3 kg The dimensions of the MS224 EX2B are 24 5 cm x 25 5 cm and the weight is 0 26 kg The dimensions of...

Page 22: ...ction is established via the 2 pin MUS connector on MS224 CPUKON card I 7 EXTERNAL RELAY An external relay which is rated for 250 VAC 24 VDC at a maximum current of 2 A exists on the MS224 CPUKON card...

Page 23: ......

Page 24: ...Guide Edition 3 2 21 II ACCESSORIES To offer you a full telecommunication system MS224 is equipped with many accessories These accessories are shown in the following figure and explained one by one i...

Page 25: ...Card Telephone DSS Card CONSOLE Socket Pin No Signal RJ Plug Pin No 1 12 VDC 6 2 Busy 3 A ext 11 3 ext 11 4 B ext 11 4 ext 11 5 GND 2 6 Data 1 The input of 12 VDC is regulated to 5 VDC by telephone D...

Page 26: ...es LT48 Feature Phone and LT48 H Handsfree Feature Phone the second one being half duplex The LT48 H Feature Phone is equipped with a 2 x 16 menu driven LCD which offers self explanatory messages for...

Page 27: ...0 Direct Station Select Module which is used as an add on module for OP48 H Consoles and LT48 H Feature Phones is a programmable keypad including 80 multipurpose keys and 80 corresponding LEDs Each ke...

Page 28: ...mary function of the key The BDP Busy Display Panel together with the 2 Character Display shows the states of 200 extensions and 28 lines as well as some system features DSS40 handles the 4 digit phys...

Page 29: ...5 cm and the weight is 0 7 kg II 2 SERIAL INTERFACE CM224 PK224 CM224 PK224 SERIAL PRINTER INTERFACE II 2 A CM224 CALL RECORD LISTING INTERFACE AND OR PK224 PC CONSOLE INTERFACE Using the serial commu...

Page 30: ...a 25 pin D type plug at the PC end and a 4 pin RJ plug at the exchange end to be attached to the 4 pin RJ socket named PC CM on MS224 CPUKON card The software operates under DOS CM224 PK224 This is a...

Page 31: ...e 4800 Bps The CM224 and PK224 modules are able to set the communication protocol to the appropriate values automatically DATA FORMAT OF CM224 A call record consists of two lines each followed by Carr...

Page 32: ...ne number 50 1 Space 51 4 Metering Pulse count 55 1 Space 56 7 Call cost 63 1 Space 64 variable Number dialed NOTES Only one of the PC interfaces CM224 and or PK224 modules or the serial printer can b...

Page 33: ...or PK224 modules or the serial printer can be installed to an MS224 system at a time since they use the same serial port PC CM socket of the MS224 CPUKON card The selection among these devices is mad...

Page 34: ...es At most two EVM FE cards can be installed on the EVM224 card in addition to the onboard one Each EVM FE card has a message capacity of 2 minutes Thus EVM224 can have a maximum Auto Attendant messag...

Page 35: ...ming through the network terminator NT1 of PTT and the analog lines of the MS224 system The adaptor also supports many EURO ISDN facilities for Basic Rate Access The function of IA12 ISDN Adaptor is t...

Page 36: ...g a connection box at one end and a 6 pin RJ plug at the other end also comes with the adaptor The EXP IA12 Expansion Board has one 8 pin RJ45 socket for connection to the S0 line coming from NT1 and...

Page 37: ...ine Identification Presentation COLP Connected Line Identification Restriction COLR Advice of Charge at Call Setup AOC_S Advice of Charge During Call AOC_D Advice of Charge at the End of Call AOC_E Th...

Page 38: ...ogrammable for the desired extension number as well as the PG100 Local Pager IMPORTANT The operating frequency of PG100 Local Pager is 167 050 MHz with a 25 KHz Bandwidth The coverage area of PG100 is...

Page 39: ...48 H telephones or DSS40 and DSS80 modules connected to the system it is preferable to feed PG100 over the power adaptor that is to be procured locally The dimensions of PG100 are 24 cm x 19 cm x 4 5...

Page 40: ...nst lightning and radio interference KAREL has external modules that can be connected to both extensions and lines These modules are presented in two different models a FPBASE Filter Protection Base U...

Page 41: ...stallation Maintenance Guide Edition 3 2 38 Figure A 26 The dimensions of the FPBASE are 18 cm x 12 cm x 3 cm and the weight is 0 4 kg The dimensions of the FPEXP are 17 cm x 12 cm x 2 5 cm and the we...

Page 42: ...software facilities which may be activated by any user of the system Operator features are the software facilities which may be activated only by the operator of the system The operator is the first...

Page 43: ......

Page 44: ...ing external calls 8 MF Receiver Capacity 24 12 x 2 9 Connectors Lines and extensions RJ plug External relay and external music 623K4 type External interfaces RJ plug 10 External connections Standard...

Page 45: ...c on 300 msec off 300 msec on 2000 msec off 5 Message waiting dial tone 500 Hz 300 msec on 300 msec off 300 msec on 300 msec off 300 msec on 2000 msec off 6 Error tone 500 Hz 300 msec on 300 msec off...

Page 46: ...mages should be reported immediately I 3 ENVIRONMENTAL REQUIREMENTS Before installation the system should be stocked in a place where the temperature is in between 40 C o and 80 C o At start up you sh...

Page 47: ......

Page 48: ...all The template also has the necessary information to hang the system on a proper location on the wall that is the bottom drill holes must be 130 cm above the floor To install the system see Figure B...

Page 49: ...stablished through the mains cable of the system which is equipped with the ground wire Due to this reason it is recommended to operate the system over a mains plug that is properly grounded Checking...

Page 50: ...es must be turned off the SPS224 fixing screw on the top front part of the system rack must be loosened and the power rack must be pulled out To insert SPS224 back in the system cabinet the metal road...

Page 51: ...nd bottom parts of the plastic card holder must be pressed towards the label on the holder and then the card must be pulled out slightly till MS224 CPU FC becomes visible After that MS224 CPU FC must...

Page 52: ...Karel MS224 Installation Maintenance Guide Edition 3 2 49 Figure B 4 Figure B 5...

Page 53: ...er The plastic card holder may be then placed and fastened by the plastic lock mechanism II 4 EXPANSION MODULES MS224 EX1 consists of MS224 EX1B and CON1 cards Similarly MS224 EX2 includes MS224 EX2B...

Page 54: ...bottom part of the system rack MS224 EX1 or MS224 EX2 must be then pushed inside the cabinet so that the connector at the back of the card fits to the one on the backplane Finally the plastic lock me...

Page 55: ...16 cables fitting in the corresponding holes on the bottom front part of the system rack the bottom cover of the system must be inserted back slightly Then the free ends of CBL 16 cables as well as t...

Page 56: ...can be fixed to the connection box easily The other free end of the cable has also the corresponding RJ socket at the backside of the telephone or DSS module The system itself also comes with the syst...

Page 57: ...OLE socket on MS224 CPUKON card 2 The Data 12 VDC GND signals on the connection box of the system data cable must be wired in parallel to the corresponding pins of the connection box of the telephone...

Page 58: ...m data cable must be connected to the CONSOLE socket on MS224 CPUKON card 2 The connection box must be removed from the telephone data cable 3 One of the RJ plugs on the telephone data cable must be a...

Page 59: ...or DSS80 module to the LT48 H or OP48 H telephone see Figure B 11 1 Remove the screw at the bottom of the telephone 2 Remove the two screws at the bottom corners of the DSS module 3 Place the plastic...

Page 60: ...Feature Phones are connected to the system in this way the distance between the system and the LT48 Feature Phones cannot exceed 25 meters In such a case the performance can be further improved by co...

Page 61: ...lug at one end of the PC Exchange cable must be connected to the PC CM socket on MS224 CPUKON card 2 The 25 pin D type plug at the other end of the PC Exchange cable must be attached to the security p...

Page 62: ...gramming code for selecting the PC as the CRL Call Record Listing media as explained in the MS224 Programming Guide III 2 B SERIAL PRINTER INTERFACE CABLING 1 The 4 pin RJ plug at one end of the Print...

Page 63: ...mounted on the wall with a couple of anchor plugs and screws For this 1 Drill two holes which are 7 5 cm apart 2 Drive the anchor plugs into the holes 3 Insert the screws into the anchor plugs 4 Hang...

Page 64: ...the ring button For this 1 Loose the screws at the top and the bottom of the doorphone and open the front cover 2 Loose the screws at the back of the ring button and disconnect the two wire cable bet...

Page 65: ...on 3 2 62 Figure B 16 III 4 EXTERNAL ANNOUNCEMENT SYSTEM CABLING Any external announcement system can be connected to MS224 system through the doorphone DIA socket on MS224 CPUKON card The following f...

Page 66: ...the amplifier must be connected through the external relay on the MS224 CPUKON card using the 2 pin XREL connector and the system must be programmed accordingly The following figure is to give an idea...

Page 67: ...rmed up of two parts One is a cable with a 6 pin RJ plug at both ends and the other one is a connection box The connection box is not used for connecting IA12 to the MS224 system The signals on the co...

Page 68: ...he bottom of the IA12 cabinet must be removed so as to access the analog line connectors on the EXP IA12 card IMPORTANT The first channel of the IA12 motherboard or EXP IA12 card must be connected to...

Page 69: ...s connected to the system For the first adaptor all the dip switches must be OFF For the second one the dip switch 3 must ON and the others must be OFF and for the third one which can have only the IA...

Page 70: ...fixed to the space with three screws The figure below illustrates this installation Figure B 21 CABLING The EVM224 card has a 6 pin RJ socket on the component side of the card This has a corresponden...

Page 71: ...ust be installed on the DRAM socket marked as D1 and the second EVM DE card must be installed to the socket marked as D2 whereas the third EVM DE card must be installed to the socked marked as D3 See...

Page 72: ...f the consoles and feature phones the pager data cable is formed up of two parts One is a cable with a 6 pin RJ plug at both ends and the other one is a connection box The connection box has a 6 pin R...

Page 73: ...e Phones and DSS80 DSS40 Direct Station Select Modules For connecting the PG100 pager to the system 3 The Data 12 VDC GND signals on the connection box of the system data cable must be wired in parall...

Page 74: ...distance between the system and the PG100 Local Pager cannot exceed 100 meters POWER CONNECTION PG100 can be also directly connected to mains voltage through a 12 VDC power adaptor Normally PG100 rece...

Page 75: ...whereas CON2 card has 4 RJ sockets for 16 extension telephones For connecting a standard telephone set to the system the wires of the cable CBL 16 cable or any similar cable procured locally coming fr...

Page 76: ...washers to carry the chassis ground to the upper modules The following figure illustrates the installation of an FPEXP on top of an FPBASE Figure B 27 CABLING During the installation of FPBASE and FPE...

Page 77: ...cal distance but the length of the cables between the system and the modules III 10 EXTERNAL MUSIC SOURCE CABLING A music source tape recorder radio or CD player can be connected to the system to be u...

Page 78: ...ivated when an external party is parked or put on hold or a user activates Background Music facility Hence the music source remains on only while a call is parked or put on hold or when a user is list...

Page 79: ...e Guide Edition 3 2 76 CABLING The connection to the external relay should be made through the 2 pin XREL connector on the MS224 CPUKON card The following figure illustrates the connection of the rela...

Page 80: ...is inserted to the correct connector properly c Replace the EVM FE card if any d Replace the EVM224 card e Replace the MS224 CPUKON card 3 No Voice Mail message can be recorded a Check the cable conn...

Page 81: ...oes not function a Check the cabling of the doorphone b Replace the doorphone c Replace the MS224 CPUKON card d Replace the CPU224 card 9 LB or TE is displayed on the consoles and feature phones a Che...

Reviews: