background image

TEICH-AIRE MANUAL

1

800 Deere Rd. Prescott, WI 54021  |  715.262.4488  |  sales@kascomarine.com  |  kascomarine.com

MOVING WATER FORWARD, SINCE 1968

Operation & 

Maintenance

Manual

Document number 771068 

Document version 2021.1.0

KM SERIES

COMPRESSOR

Teich-Aire

Summary of Contents for Teich-Aire KM Series

Page 1: ...00 Deere Rd Prescott WI 54021 715 262 4488 sales kascomarine com kascomarine com MOVING WATER FORWARD SINCE 1968 Operation Maintenance Manual Document number 771068 Document version 2021 1 0 KM SERIES COMPRESSOR Teich Aire ...

Page 2: ... TABLE OF CONTENTS 715 262 4488 kascomarine com sales kascomarine com QUESTIONS Product Overview 2 Installation 3 Electrical 4 Operation 5 Maintenance 6 Troubleshooting 7 Warranty 8 Other Repairs 9 Repair Contact Form 10 ...

Page 3: ...armful elements of the outdoor environment Ambient air temperature readings taken 4 away from any surface of the compressor must not exceed 104 F 40 C Ensure that adequate ventilation and cooling air flowing across the compressor is available to keep the compressor from overheating which can cause premature damage Mount the compressor to a stable rigid operating surface Using the provided shock mo...

Page 4: ... air filter in one inlet port Kasco recommends installing a pressure relief valve in an outlet port to bleed off excess pressure in case of a blocked line Check valves may be required to prevent back flow through the compressor KM 60 KM 60HC EX Pressure relief valve Air filter IN Barb fitting EX EX Pressure relief valve Air filter IN Barb fitting EX EX Pressure relief valve Air filter connected to...

Page 5: ... condition or is inadequate for the requirements of this product Failure to follow these instructions can result in fire electrical shock or death Make sure that the power supply voltage agrees with that listed on the product nameplate All cords with plugs must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances Hardwired installation...

Page 6: ... tor may exceed 70 dBA Failure to follow these instructions can result in burns eye injury or other serious injury Injury Hazard OPERATION It is your responsibility to operate this compressor at recommended pressures and permissible ambient temperatures Do not start against a vacuum or pressure load If the motor fails to start or slows down significantly under load shut off and disconnect from the...

Page 7: ...electrical power supply to unit Vent all air lines Remove filter cover Remove and replace filter element as necessary Replacement filter elements are readily available Please contact your local Kasco distributor and ask for the replacement air filter element part 771014 for KM 60 or KM 120 Models or part 771018 for KM 200 Models Reinstall filter element and cover MAINTENANCE WARNING Allow product ...

Page 8: ...lve is set too high Inspect and adjust Relief valve is set too low Inspect and adjust Plugged pressure line Inspect and repair Low voltage will not start Check power supply Incorrect voltage Check power supply Worn cup piston hitting cylinder Replace Cylinder misadjustment Realign Leaky hose or check valve Replace Dirt or liquid on top of piston Inspect and clean Motor not wired correctly Check wi...

Page 9: ...it may be sent to any Kas co Authorized Repair Center for evaluation and repair Please call Kasco at 715 262 4488 prior to shipping to receive any updated information and or Repair Form or call to locate your nearest Authorized Repair Center You can also email Kasco at sales kascomarine com Please include the repair form received from Kasco or your local distributor with the shipment If no repair ...

Page 10: ...amount stated by the customer Example Please repair if total is under 150 00 before shipping charges All estimates that are rejected for repair will be destroyed unless otherwise directed by the customer If the customer would like the unit returned we will restore the unit as closely as possible to the condition in which we found it and ship at the customer s expense including shipping and handlin...

Page 11: ...a chemical treatment or wastewater application circle one Yes No Additional notes Kasco Marine 800 Deere Road Prescott WI 54021 Attn Repairs Kasco requires that all equipment sent for repair MUST be accompanied by this form and marked to Repairs attention Unit should be cleaned before shipping Kasco is NOT responsible for shipping damage accrued in return shipment It is the responsibility of the c...

Reviews: