background image

 
 
 

DIGITAL IMAGE SCANNER 

KIP 600

 

Setup Procedure 

 

Ver. A.4 

August 11, 2006 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

KATSURAGAWA ELECTRIC CO., LTD.

  

Summary of Contents for KIP 600

Page 1: ...DIGITAL IMAGE SCANNER KIP 600 Setup Procedure Ver A 4 August 11 2006 KATSURAGAWA ELECTRIC CO LTD ...

Page 2: ...ner Utility 16 8 2 Starting Scanner Utility 18 8 3 Scanner Adjustment 19 The machine had passed strict inspection after careful adjustment in the factory and then it was packaged and shipped Installation is an important work to make the machine work at customer s site as same as it has passed our strict inspection before shipment A service engineer has to understand machine s function very well In...

Page 3: ...et stikkontakt SWEDEN Apparaten skall anslutas till jordat uttag 3 To completely disconnect the equipment from the power source please draw the power plug from the outlet The outlet must be easily accessible near the equipment 4 The temperature must be within the range from 10 to 32 degrees centigrade and the humidity must be from 20 to 80 5 Prevent the equipment from fire dust and direct sunlight...

Page 4: ... If the KIP 600 is very much cooled down having been kept in a cold warehouse for a long time carry it to the room you will install and then leave it in that room for 6 hours or longer before removing its packages When the KIP 600 has been warmed up enough by the room air after 6 hours or longer start removing the packages The KIP 600 may get dewed if you remove the packages although it is still c...

Page 5: ...cessories for the KIP 600 Check the all contents Part Name Number of article USB Cable 1 Original Tray 2 Eject Guide 2 Shading Sheet Calibration Sheet in Calibration Sheet Box 2 types 1 1 User s Manual CD 1 User s Manual German hardcopy 1 Setup Procedure 1 ...

Page 6: ...Connect the power cord connector 2 to Inlet Socket 3 on the rear 2 3 WARNING The power cord must conform to the safety standard of the country or region in which the machine is installed Do not handle the power plug with a wet hand It may result in receiving an electrical shock Be sure to ground the machine Use a dedicated outlet for the KIP 600 Many loads on a single outlet may cause overheating ...

Page 7: ...6 3 Plug the power cord to a dedicated outlet ...

Page 8: ...1 Connect the Type B connector 1 to USB Terminal 2 on the rear 2 Connect the Type A connector to the USB Terminal on a KIP printer NOTE You can purchase another USB Cable separately Make sure that the cable satisfies the following specifications USB 2 0 High speed data transfer Shielded Shorter than 3 meters Printer side Type A male Scanner side Type B male 1 2 ...

Page 9: ...sories 1 Attach Original Trays 1 to the notches on the rear 2 Pull Levers 2 up to open Top Cover 3 3 Remove protecting films on the upper and bottom Guide Plate 1 1 CAUTION Be careful not to catch a finger in Top Cover 3 2 ...

Page 10: ...9 4 Attach Eject Guides 4 to Top Cover NOTE Insert Eject Guide tabs to the notches on the front of Top Cover Slide Eject Guide 4 until it stops 4 4 4 tab notch ...

Page 11: ...10 5 Fully move Top Cover 3 backward to unlock it and close it CAUTION Be careful not to catch a finger in Top Cover 3 ...

Page 12: ...e rear 2 Wait until READY LED 2 and ERROR LED 3 go off 3 Press the Power Button 4 4 The Power Button 4 and READY LED 2 lights when the KIP 600 is ready READY ERROR EJECT STOP ERROR EJECT STOP READY 2 3 ERROR EJECT STOP READY 4 2 ERROR EJECT STOP READY 4 Press this side 1 ...

Page 13: ...his provides a clearer and more accurate scan image Initialize the KIP 600 using Scanner Utility 8 1 Installation 8 1 1 Installing USB Driver 1 Disconnect the USB Cable on a KIP printer and connect it to your PC 2 Turn on both your PC and the KIP 600 Found New Hardware Wizard starts automatically Click Next ...

Page 14: ...13 3 Choose Search for a suitable driver for my device recommended Click Next Choose this 4 Set Technical CD ROM to your optical disk drive Mark CD ROM drives and click Next Mark this ...

Page 15: ...14 5 The following message is indicated when the necessary driver is found Click Next 6 Click Next when the following message is indicated 7 Complete the Found New Hardware Wizard clicking Finish ...

Page 16: ...15 8 Open Device Manager and confirm that KIP K105SC is operating properly ...

Page 17: ...ng Scanner Utility 1 Set Technical CD ROM to your optical disk drive Locate Scanner Utility setup file and run SETUP EXE 2 The Setup Program starts Click Next 3 The destination of the software can be changed Click Next ...

Page 18: ...17 4 The name of the program folder can be changed Click Next 5 The following message is indicated when all files have been copied Click Finish ...

Page 19: ...18 8 2 Starting Scanner Utility Start Scanner Utility by Start _ Program _ ScannerUtility _ ScannerUtility Utility initial screen ...

Page 20: ...ct the KIP 600 and the PC directly with a USB 2 0 cable 2 Start Scanner Utility 3 Select Calibration under Adjust 4 At first it is required to calibrate all pixels Select All and then click Execute You will be asked to set the original ...

Page 21: ...nner reads Shading Sheet 7 When finished scanning click OK Click Confirm to check the result of Shading NOTE One corner of Shading Sheet is cut off Set Shading Sheet so that this corner is on the left and on the front side of the machine NOTE The dialog attempts a rescan Just click OK Do not remove Shading Sheet ...

Page 22: ...y check whether the density is even or not If the density is even at every place finish the Calibration clicking Close There may be some place of which density is different from others as the following image As this pixel is defective it is necessary to calibrate it individually in the next step Defective pixel ...

Page 23: ...rt 11 Move the pointer onto the scan image and you will find a kind of red cursor red cross cursor defective pixel NOTE Sometimes the density may be different between left and right as the following image This is not a problem but it is just the border of image blocks ...

Page 24: ...selected by this operation If there are some more defective pixels select them in the same way Match the vertical line to a defective pixel 13 Click Execute and the selected defective pixel is compensated individually 14 You will be asked to set the original again Set Shading Sheet to the scanner and click OK Check the result of Shading again ...

Page 25: ...24 15 Select Color Correction under Adjust 16 Click Scan You will be asked to set the original ...

Page 26: ...original and the scanner reads Calibration Sheet 19 When finished scanning click OK Click Confirm to check the result of Calibration NOTE Position Calibration Sheet in the center of Original Table so that the numbers on Calibration Sheet are at the top NOTE The dialog attempts a rescan Just click OK ...

Page 27: ...20 The scan image of Calibration Sheet is displayed Click Get 21 A red cross cursor appears in the window Click the 6 reference points where the following pictures show match them markers red cross cursor ...

Page 28: ...ints 23 Click Confirm Scan Calibration Sheet again Check the scan image and click Close to finish You can enlarge the scan image by dragging with the right button of mouse Press F2 Key when you would like to go back to the reduced image Reference Align these markers Red cross cursor ...