background image

Instructions for use

INTRA Motorhandstück PROPHYwiz 181 P - REF
1.003.2278

Summary of Contents for INTRA PROPHYwiz 181 P

Page 1: ...Instructions for use INTRA Motorhandstück PROPHYwiz 181 P REF 1 003 2278 ...

Page 2: ...Distributed by KaVo Dental GmbH Bismarckring 39 D 88400 Biberach Phone 49 7351 56 0 Fax 49 7351 56 1488 Manufacturer Kaltenbach Voigt GmbH Bismarckring 39 D 88400 Biberach www kavo com ...

Page 3: ...oving the prophylaxis head 12 6 Reprocessing steps in accordance with ISO 17664 13 6 1 Preparation at the site of use 13 6 2 Manual Reprocessing 13 6 2 1 Manual cleaning external 13 6 2 2 Manual internal cleaning 13 6 2 3 Manual external disinfection 13 6 2 4 Manual internal disinfection 14 6 2 5 Manual drying 14 6 3 Automated reprocessing 14 6 4 Care products and systems Servicing 14 6 4 1 Servic...

Page 4: ...ler or the KaVo Repair Service directly 49 0 7351 56 1900 service reparatur kavokerr com Target group This document is intended for dentists and their assistants The startup section is also intended for service technicians General marks and symbols Refer to the chapter on Safety Warning symbol Important information for users and service technicians Action request CE mark European Community A produ...

Page 5: ...idity Protect from moisture Protect from impact HIBC Code Hazard levels The warning and safety notes in this document must be observed to prevent personal injury and material damage The warning notes are designated as shown below DANGER In cases which if not prevented directly lead to death or severe in jury WARNING In cases which if not prevented could lead to death or severe in jury CAUTION In c...

Page 6: ...sories appropriately before disposal 2 2 Technical condition A damaged device or components could injure patients users and third parties Only operate devices or components if they are undamaged on the outside Check that the device is working properly and is in satisfactory condition before each use Have parts with sites of breakage or surface changes checked by the Ser vice If the following defec...

Page 7: ...tional and regional regulations 2 5 Service and repair Repairs and servicing may only be performed by trained service personnel The following persons are authorised to do this Service technicians of KaVo branches after the appropriate product training Service technicians of KaVo authorised dealers after the appropriate product training Observe all the following items during servicing work Have the...

Page 8: ... properly trained user You need to comply with the fol lowing the applicable health and safety regulations the applicable accident prevention regulations these Instructions for use According to these regulations the user is required to to only use equipment that is operating correctly adhere to the specified intended use to protect him or herself the patient and third parties from hazards to preve...

Page 9: ...ustomer 20 µm 3 3 Operating conditions Temperature 5 o C to 40 o C 41 o F to 104 o F Maximal rel humidity 80 Air pressure 700 hPa to 1060 hPa 10 psi to 15 psi 3 4 Transportation and storage conditions NOTICE Startup after refrigerated storage Malfunction Prior to startup strongly refrigerated products must be allowed to warm up to a temperature of 20 C to 25 C 68 F to 77 F Temperature 20 C to 70 C...

Page 10: ...sterilise the product and accessories before disposal See also 2 6 Reprocessing steps in accordance with ISO 17664 Page 13 NOTICE Damage to the handpiece caused by spray air and spray water Damage to the handpiece Before startup unselect spray air and spray water on the supply unit 4 1 Check the pressure NOTICE Contaminated or moist compressed air at the compressed air connec tion Premature wear E...

Page 11: ...t diameters from 2 3 to 2 35 mm CAUTION Use of impermissible prophylaxis heads Injury to the patient or damage to the medical device Comply with the manufacturer instructions and use the prophylaxis heads properly Only use prophylaxis heads that do not deviate from the specified data CAUTION Damaged prophylaxis head Injuries Check the prophylaxis head for damage before each use See the manufacture...

Page 12: ...ophylaxis head 12 22 5 3 Removing the prophylaxis head CAUTION Hazard due to incorrectly stored instrument Injury and infection from clamped prophylaxis head After each treatment place the instrument properly in the cradle without the prophylaxis head Remove the prophylaxis head axially from the handpiece ...

Page 13: ...head from the medical device Remove all residual cement composite or blood immediately Do not place in solutions or similar substance 6 2 Manual Reprocessing NOTICE Never reprocess this medical device in an ultrasonic device Malfunction and material damage For manual cleaning only 6 2 1 Manual cleaning external Accessories required Tap water 30 o C 5 o C 86 o F 10 o F Brush e g medium hard toothbr...

Page 14: ...ables required Cloths for wiping the medical device Spray the disinfectant on a cloth then wipe down the medical device and allow the disinfectant to act according to the instructions of the disinfectant manufacturer Follow the instructions for use of the disinfectant 6 2 4 Manual internal disinfection Not applicable 6 2 5 Manual drying If there is any residual moisture after cleaning and disinfec...

Page 15: ...pac bag Use an appropriate cannula and apply spray into the smaller of the two large tubes Press the spray key for 1 to 2 seconds Note Additional servicing is required if the working speed decreases due to con tamination or particles being present in the air supply system Chuck care KaVo recommends servicing the chucking system once weekly Remove the head and spray into the opening using the tip o...

Page 16: ...e mounted there Press the handpiece together with the guide bush of the chuck to be ser viced against the tip of the service coupling Press the button marked with the chuck service symbol Note Close the chuck service mode Option 1 Place the dental handpieces in the QUATTROcare PLUS 2124 A close the front door and start theservice procedure Option 2 After three minutes with no service procedure run...

Page 17: ...ter each use i e after each cleaning disinfection and before each sterilisation Take the head off Unscrew the motor handpiece from the hose Service the product in the QUATTROcare See also 2 Instructions for use KaVo QUATTROcare 2104 2104A 2124A Servicing the clamping chuck KaVo recommends servicing the chucking system once weekly Remove the head and spray into the opening using the tip of the spra...

Page 18: ... after the steril isation cycle The KaVo medical device has a maximum temperature resistance up to 138 280 4 F Sterilisation parameters Select a suitable procedure depending on the available autoclave from the fol lowing sterilisation processes Steriliser with triple pre vacuum at least 3 minutes at 134 C 1 C 4 C 273 F 1 6 F 7 4 F Steriliser using the gravity method at least 10 minutes at 134 C 1 ...

Page 19: ...ent 7 Auxiliary equipment Available from dental suppliers Material summary Mat no Seal 0 553 1872 Cleanpac 10 units 0 411 9691 Material summary Mat No KaVo Spray 2112 A 0 411 9640 ROTAspray 2142 A 0 411 7520 QUATTROcare plus Spray 2140 P 1 005 4525 Spray head INTRA KaVo Spray 0 411 9911 19 22 ...

Page 20: ... defects and their consequences that have arisen or may arise from natural wear improper handling cleaning or maintenance non compliance with operating maintenance or connection instructions calcination or corrosion contaminated air or water supplies or chemical or electrical factors deemed abnormal or impermissible in accordance with KaVo s instructions for use or other manufacturer s instruction...

Page 21: ......

Page 22: ...1 003 5609 bd 20180604 04 en ...

Reviews: