KTD-600 series

Digital Pressure Sensor Switch

KTD - 

600

 Series

KTD-600

Digital Pressure Sensor Switch

 Pressure range

Nil

-0.95 ~ 9kgf/

cm

2

 (Pneumatic)

V

-0.97 ~ 0kgf/

cm

2

 (Vacuum)

How to Order

Model

KTD-600

KTD-600V

Pressure type

Compound pressure 

(Pneumatic)

Negative pressure 

(Vacuum)

Display pressure range

-0.95 ~ 9kgf/cm

2

 

-0.99 ~0kgf/cm

2

Rated pressure range

-0.95 ~ 9kgf/cm

2

-0.97 ~ 0kgf/cm

2

Proof pressure

2 times of rated pressure

1.5 times of rated 

pressure

Fluid

Air, Non-corrosive gas

Power supply

12~24VDC 

±

 10% (Ripple P-P)

Current consumption

Below 30mA

Ambient temperature

0

~50

 (at non-freezing status)

Strorage temperature

-40

~125

 (at non-freezing status)

Humidity

30~80%RH (at non-freezing status)

Output temperature 

characteristic 

-0.1~-0.2% Span/

 

(-20

~100

)

-0.2~-0.3% Span/

 

(-20

~100

)

Linearity

±

0.3% Span 

Response time

1~99 Step (1Step = 5msec) 

Control output

NPN Open collector 2 individual output

(Max. load current ≤100mA)

Analog output

Analog Mode 

(0~6 Mode)

Analog Mode

(0~4 Mode)

Resolution : 1~5V (≥1/800)   0~5V (≥1/1000)

Display method

- 1LED (

±

 display), 3 digit 7 segment

- (OUT1, OUT2) 2 output displayed by 2 LED

Material

 Case & Panel holder set : PC

Pressure port

M5 (Built-in)

Wire

Ø4.2 / 24AWG X 5Core / Approx. 1.5m (

±

5%)

Accessory

Manual, Mounting bracket, Panel holder set

Display pressure unit

kPa, bar, psi

kPa, mbar, psi

Weight

156g

Specifications

KTD-600 series

Function

 Change display unit

There are different type of pressure unit. Please select the proper unit 

depending on application.  When changing the display unit, preset value will 

be calculated according to the display unit. 

 Zero point adjustment

This function is to set the display value of pressure at zero when port is 

opened to atmospheric pressure. Press ZERO key for more than 2sec in 

RUN mode set value forcibly. When the zero point adjustment is completed, it 

will return to RUN mode automatically.

 Change response time  

It is able to set 100 kinds of response time (5~495ms) and if the response 

time is getting longer, the sensing value will be more stable.

 Change output mode 

There are 4 kinds of control output modes. (Please refer output operation 

mode).

Output response to cable OUT 1 and OUT 2 according to output mode.

-Control output 1 : Black cable (OUT1)

-Control output 2 : White cable (OUT2)

 Analog output status display

The output of the pressure sensor is indicated by flashing of 2 LEDs.

- OUT 1 is ON, LED 1 will be ON

- OUT 2 is ON, LED 2 will be ON

 Real time display

When advance to Parameter setting mode, if the setting value is changed, 

the output will change according to the changed value.

 Automatic RUN mode reset

When changing unit, set unit by using UNIT key and it will return to RUN mode 

automatically after 1sec.

When advance to Parameter setting mode, if any key is untouched for over 

10 sec, it will return to RUN mode automatically.

 Analog output

- Analog output cable : Grey cable

- Analog output status : Please refer to analog output mode of each model.

Features

● 

Indicate positive and negative pressure

● 

Compact design and light weight

● 

One touch zero adjustment function

● 

Return function in automatic operating mode  

● 

Independent 2-channel output according to user setting

● 

Use high precision semiconductor pressure sensor. 

  Widely used, when precise pressure control is required, 

  such as semiconductor manufacturing line, medical  

  equipment, automation line and etc. 