CALIBRATING YOUR KEISER M SERIES EQUIPMENT

Procedure for software version U406 and above

STEP 1

STEP 2

STEP 3

555512_D

1 ROTATION ONLY

Turns on Computer

Be sure to read all steps very closely before beginning

. You have 25 seconds to go from 

STEP 2 to STEP 9. After 25 seconds the computer will exit calibration mode and you must 
allow it to shutdown before attempting to calibrate again. All work is done from the left 
side of the machine, except on the M5, the work is done from the right and the plastic 
cover must be removed.

Move  the  red  shifter  handle  all  the 
way down.

Note:  If  you  are  unsure  of  your  software 
version,  check  the  version  by  removing  the 
batteries  for  at  least  20  seconds.  Reinstall 
the  batteries  and  watch  the  display  during 
start-up  for  “U###”. Allow  the  computer  to 
go to sleep before continuing to step 2.

Slowly  rotate  the  pedal  until  the 
computer  turns  on.  Once  it  comes 
on,  continue  turning  for  one-half 
revolution  then  stop  the  crank 
arm.  Zeroes  will  appear  on  the 
time  slot  on  the  display  as  shown 
to the right.

Slide  your  red  calibration tool  onto 
the flywheel as shown.