kENDALL

Electronic Thermometer

Operating Manual
Thermomètre électronique - Manuel de fonctionnement
Elektronisches Thermometer - Bedienungsanleitung
Termometro elettronico - Manuale d’uso
Termómetro electrónico - Manual de funcionamiento
Elektronisk termometer - Bruksanvisning
Elektronische thermometer - Gebruiksaanwijzing
Termómetro Electrónico - Manual de utilização
Elektroninen lämpömittari - Käyttöopas
Elektronisk termometer - Brugervejledning
Ηλεκτρονικό θερμόμετρο - Εγχειρίδιο λειτουργίας
Elektronický teploměr - Návod k obsluze
Elektronikus hőmérő - Működtetési kézikönyv
Электронный термометр - Руководство по эксплуатации
Termometr elektroniczny - Instrukcja obsługi
Elektronik Termometre - Çalıştırma Kılavuzu
Elektronisk termometer - Brukerhåndbok

3000

AD/ADA

0123

Summary of Contents for FILAC 3000 AD

Page 1: ... U K LTD GOSPORT PO13 0AS U K 182508 kENDALL Electronic Thermometer Operating Manual Thermomètre électronique Manuel de fonctionnement Elektronisches Thermometer Bedienungsanleitung Termometro elettronico Manuale d uso Termómetro electrónico Manual de funcionamiento Elektronisk termometer Bruksanvisning Elektronische thermometer Gebruiksaanwijzing Termómetro Electrónico Manual de utilização Elektr...

Page 2: ... Last Temperature 6 Pulse Timer Mode 6 Bio Tech Mode Option Configuration Menu 7 VI Cleaning and Sterilization 9 VII Battery Replacement Installation 9 VIII Mounting Instructions 9 IX Anti Theft Features Options 9 X Troubleshooting 10 XI Specifications 10 XII Customer Service 11 XIII Warranty 13 This product contains software solely owned by Tyco Healthcare Group LP Tyco Healthcare Group LP grants...

Page 3: ...General Information 1 The FILACTM 3000 electronic thermometer is a fast highly accurate and easy to use clinical instrument for measuring patient temperatures by Oral Axillary or Rectal means 2 The electromagnetic compatibility of this device has been verified by test according to the EN60601 1 2 2005 requirements 3 This device requires no user maintenance other than periodic cleaning and replacem...

Page 4: ...10 Do not open unit No user serviceable parts inside Opening of device may affect calibration and voids warranty 11 Disposal of used probe covers must be performed in accordance with current medical practices or local regulations regarding disposal of infectious biological medical waste 12 Removal of the batteries is recommended if the unit is not going to be used for an extended period of time 13...

Page 5: ...eliver consistent temperature measurements with FILAC 3000 Electronic Thermometers The factory calibration and final acceptance determination of a FILAC 3000 Electronic Thermometer is dependent on the use of Tyco Healthcare Group LP produced FILAC 3000 ACCUSYSTEM probe covers The use of generic probe covers or other probe covers not produced by Tyco Healthcare Group LP is not supported or sanction...

Page 6: ...bes 1 For aiding in infection control use only the Blue probe and Blue isolation chamber for Oral and Axillary temperature taking The Red probe and Red isolation chamber must only be used for Rectal temperature taking 2 Do not attach a Red probe to a Blue isolation chamber or vice versa 3 To remove or replace any isolation chamber probe assembly grasp the isolation chamber from each side as shown ...

Page 7: ...rature is displayed 12 To change between Celsius and Fahrenheit scales press the C F button Press again as needed 13 Eject the used cover into a bio waste container by pushing top button 14 After returning the probe to the probe well the temperature is stored for recall until the probe is once again withdrawn If the probe is returned to the probe well before the long beep is heard no temperature w...

Page 8: ... not available with Axillary or Rectal Body Sites with Cold Mode or when in Direct Mode Cold Mode 1 Cold Mode is provided for use in applications where body temperatures may be lower than normal such as for patients recently out of surgery 2 See instructions within the Bio Tech Mode section to turn this feature On or Off 3 When selected as indicated by the snowflake on the display the probe prehea...

Page 9: ... shown in the alpha numeric section of the display 3 The thermometer is now in Bio Tech mode To navigate the Bio Tech mode menu follow the chart below 4 The Pulse Timer button is used to move forward through the different configuration options C F button is used to change an option configuration 5 To exit Bio Tech mode and resume normal operation press the Site and C F buttons at the same time and...

Page 10: ... ON 50 ON 90 ON ON OFF ON OFF ON OFF Step to next character location ON OFF ON OFF No Function Start test No Function View Serial Number The Pulse Timer button is used to move forward through the different configuration options Press the C F button to step to next character location Press the Site button to return to the initial LCD Test screen What You See or Hear Option Configuration X YZ with m...

Page 11: ...ed spring and lifting up 4 Be certain to dispose of used batteries in a manner consistent with local environmental and institutional policy for lithium or alkaline battery disposal 5 To install new batteries place the negative end on the spring Press down firmly to compress spring and tilt battery into place 6 To replace the battery door insert the tab on the bottom of the door into the slot on th...

Page 12: ...ct to electrical shock fire and mechanical hazards only in accordance with UL60601 1 Classified with respect to electrical shock fire and mechanical hazards only in accordance with CAN CSA C22 2 NO 601 1 Dimensions Approximate without base in 3 2 W x 6 0 H x 2 1 D mm 84 W x 152 H x 56 D Dimensions Approximate with base in 4 1 W x 7 5 H x 3 1 D mm 105 W x 190 H x 79 D Weight Approximate without bas...

Page 13: ...torage and operation are exceeded The FILAC 3000 electronic thermometer is in compliance with the following International Regulatory and Safety standards UL60601 1 CAN CSA C22 2 No 601 1 EN60601 1 2005 EN60601 1 2 2005 EN 12470 3 2000 MDD 93 42 EEC BS EN980 1997 ASTM E 1112 2006 XII Customer Service The circuitry of the FILAC 3000 electronic thermometer is not customer serviceable In particular el...

Page 14: ...rder No 502000 Note Use of any other brand or style probe cover will result in erroneous temperature readings Complete Oral Axillary Thermometer Includes electronic thermometer with Blue Oral Axillary isolation chamber and Blue Oral Axillary probe with 4 foot 1 2m cord and global manual on CD FILAC 3000EZ Reorder No 504000 FILAC 3000EZA Reorder No 504003 FILAC 3000AD Reorder No 505000 FILAC 3000AD...

Page 15: ... as warranted above during the applicable warranty period Kendall may at its option and expense replace the defective part or product with a comparable part or product repair the defective part or product or if neither replacement nor repair is reasonably available refund to Customer the purchase price for the defective part or product Dated proof of original purchase will be required Kendall does...

Page 16: ...ate TYCO HEALTHCARE GROUP LP MANSFIELD MA 02048 MADE IN U S A 2007 TYCO HEALTHCARE GROUP LP ALL RIGHTS RESERVED 070831 IN U S 1 800 962 9888 www tycohealthcare com TYCO HEALTHCARE U K LTD GOSPORT PO13 OAS U K 182508 kENDALL ENGLISH ElectronicThermometer ...