background image

Summary of Contents for 2700

Page 1: ...Kenmore 2700 17 GALLON CENTRAL HUMIDIFIER Installation Maintenance Repair Parts Troubleshooting Sears Roebuck and Co Hoffman Estates IL 60179 U S A ...

Page 2: ...e of any tool can be danger ous Be sure you knowhowto use the tools and equipmentto avoid any possiblehazards If you have any doubtwe ask that youcontactyourSears salesperson They willarrangefor profes sionalinstallation SEARS INSTALLATION WARRANTY In additionto any warranty extendedto you on the Sears mar chandiseinvolved which warranty becomes effectivethe date the merchandise isinstalled should...

Page 3: ... check my home s relative humidity First give your humidifiertime to build up the humidityto an acceptablelevel Instrumentsare availableto measurerelative humidity but from a practicalstandpoint your comfortis the best guide Youcannot depend ontable top or wall hungdial gauges 3 How long will It take my humidifier to build up the humidity In my home Much dependsonthe outsidetemperature timeof year...

Page 4: ...ieris shippedwiththe block off panel on the rightside Fig 3 This issuitableforinstallation asshown in Fig 1 above If this is suitablefor your installation removepartsas shown underDISASSEMBLY If you require the block off panel on the left side Fig 4 start with DISASSEMBLY then remove block offpanet from dghtflange and install with the same screws on leftflange FIBER PLENUM DUCTS NOTE The mounting ...

Page 5: ...l or puncha large hole in one cornerof rectangle This willallowyou to insertthe tin snipsor metalsaw I CAUTION Be sure notto drill or cut intoair conditioning coil ortubing I 7 Attachthe humidifiercase assembly on the plenum using4 8 screwsprovided Drill4 1 8 Holes CutAlong This Line _tc ou This Area Furnace Level _ne j Plenum 8 Holdcollarandflexible tube assemblyagainstcold air plenumat desiredlo...

Page 6: ...o not use copper tubing because it may become disconnected when used with hardware supplied 1 Waterforthe humidifier mustbetakenfroma nearby coldwater line Turnoffthewater supply Drainbyopeninga fau cet at a lowerlevelofthe line 2 Mountthe saddlevalve onthewater lineas closeto the humidifieras possible Youhave bean suppliedwith 10 feet of 114 plastictubing SPECIAL NOTE When measuring the distancef...

Page 7: ...ge humiditythroughoutyour home and is the locationcovered byinstallation steps 1through11 ifyoudecideonthe wallmount location the humidistat controlunitmustbe removedand mounted to the oppositeside of the plasticbackplateeo it willbe housed l_aideof the plasticcover omitsllaft extana on purchaseaddi tional low voltage wire and run wire inside of wall to exit hole withinthe loweropeningof the backp...

Page 8: ...hieveproperhumidity 2 Change knob settings as outdoor temperature changesoccur WARNING DO NOT LEAVEKNOB SET IN TEST POSI TION ABOVE 20 OR HUMIDIFIER WILL RUN CON STANTLY I IF SWEATING OF WINDOWS OR WALLS OCCURS OR IF AIR IS TOO DRY Check dial seffing Indicatorshould point to the lowest24 hour temperature If settingdoes not agree readjustknobto proper i numberandwait 24 hoursforsweatingto stop Ifdi...

Page 9: ...spect and replace if badly b_ocked with mineral deposits Media Pad available from Seam Stock No 42 14711 3 If necessary clean insideof humidifier case especially lower drain area with water and vinegar solution detergent and water or Sears All Purpose Humidifier Cleaner Stock No 42 14713 4 Install media pad by sliding top edge up and pivot ing bottom edge into position 5 Replace front panel 6 Turn...

Page 10: ...at according to outdoortemperatureas instructedon operationinstructionlabel Unit is back inoperation service hints Frequentlywhat seems to be a majorproblemcan be solvedvery easily Listedbelow are the commonconcernswithany humidifier Checkthe simplethingsfirst Removethefront panel and see if there is a crusty whitelimebuild uponthe mediapad The limebuild upwon t hurtthe humidifier butwill reduceit...

Page 11: ...sion Sleeve 29 Nut No 6 32 Thread 2 Req Screw No 6 32 x 1 2 2 Req Inlet fitting filter orifice Solenoid Valve Includes Key Nos 13 15 Outlet Fitting Plastic Compression Nut Distribution Pad Set Plastic Supply Tubing 1 4 x 10 Ft PART NO 41067501 STD610603 03022701 21594501 21594701 43148901 43149102 21581001 STD610803 28098302 35548801 21603901 35587302 41053902 21595501 DESCRIPTION Brass Insert 2 R...

Page 12: ... with the 2 6 screws DRAIN TUBE 1 Using spring hose clamp pliers expand hose clamp and remove drain tube 2 Clear internal lime and calcium deposits by flexing or striking on hard surface 3 Flush with water under pressure 4 Reinstall drain tube and hose clamp SOLENOID WATER FILTER 1 Remove water line at solenoid 2 Remove nylon elbow inlet fitting filtedoriflce assembly from solenoid valve by unscre...

Page 13: ...greement Call 9 00 a m 5 00 p m Monday Saturday 1 800 827 6655 SEARS taY fl _ J l _t_ America s Repair Speciahsts Tell Sears You Want It Installed Then Relax When Sears arranges the installation you can be sure the job is done right We will arrange for professional workmanship and we ll take care of the entire project What s more during installa tion you get insured protection against property dam...