background image

Summary of Contents for 580.5145

Page 1: ...Owner s Manual Manual del Propietario DEHUMIDIFIER DESHUMIDIFICADOR Model Modelo 580 51450 Sears Roebuck and Co Hoffman Estates IL 60179 U S A www sears com ...

Page 2: ...shed with the product Sears will repair the Dehumidifier free of charge if defective in materials or workmanship FLILL FIVE YEAR WARRANTY ON SEALED REFRIGERATION SYSTEM For five years from the date of purchase when thisDehumidifier is operatedand maintained according to owner s instructions furnished withthe product Sears will repairthe sealed refrigeration system consistingof refrigerant connecti...

Page 3: ...ove any prong from the power cord Grounding type wall receptacle Do not under any circumstances cut remove or bypass the grounding prong from this plug Power supply cord I l with 3 prong grounding plug ELECTRICAL INFORMATION The complete electrical rating of your new dehumidifier is stated on the serial plate Refer to the rating when checking the electrical requirements Be sure the dehumidifier is...

Page 4: ...ding plug To minimize possible shock hazard the cord must be plugged into a mating grounding type wall receptacle and grounded in accordance with the National Electrical Code ANSI NFPA 70 latest edition and all local codes and ordinances If a mating wall receptacle is not available it is the personal responsibility and obligation of the customer to have a properly grounded 3 prong walt receptacle ...

Page 5: ...duce the risk of fire electric shock or injury to persons read the important SAFETY instructions sect on before operating this appliance 1 CONTROL PANEL 2 GRILLE FRONT 3 POWER CORD 4 CABINET 5 AIR FILTER 6 WATER BUCKET 2 3 5 5 ...

Page 6: ...the amount of time you want the unit to run The Timer can be setfor Constant 8 hour 4 houror 2 hour When Timer buttonis pressed the Timer indicator lightsshiftas follows Constant 2 hr 4 hr 8 hr Constant TO OPERATE THE DEHUMIDIFIER 1 Plug the power cord intoan electrical outlet Press the power button 2 Set the HumidityC_ ntrolanywherebetween30 RH and 70 RH for normaloperation If you need drier air ...

Page 7: ... frost occurs the unit will cycle on and off This is normal Unplug the unit or turn the unit off until the frost melts and the room temperature rises DEFROST CONTROL When the defrost control senses frost build up on the evaporator coil it will automatically shut off the compressor The fan will continue to run to draw air across the coil and melt the frost When the coil is defrosted the compressor ...

Page 8: ...inished replace it properly NOTE To replace the bucket properly make sure the slots on the back of bucket are positioned correctly in one of three ways Place the dehumidifier directly over drain The bucket has a threaded hose connection which can be left open Drill a 1 4 6 4ram to 1 2 13mm hole in the center of the hose connection Once opened the hose connection will continually drain water from t...

Page 9: ...se and let the filter dry before replacing it CLEANING INSIDE THE UNIT After removing the air filter clean the coil on the inside with a soft brush to remove any soft and wet soil NOTE Do not allow water to enter the electrical machine compartment through the circular opening behind the coil Do not spray the coil with a hose GENERAL CLEANING Dust the front grille and the side panels with a soft br...

Page 10: ... the O Humidity Control button to not be set low Humidity lower the humidity Doors and windows may Check that all doors windows and other not be closed tightly openings are securely closed Clothes dryermaybe blowing Install the dehumidifier away from the dryer moisture laden airIntotheroom The dryer should be vented to the outside Room temperature is too The unit will not operate satisfactorily if...

Page 11: ...O DESCRIPTION 1 A 3041AD2007C 2 A 4791A10002A 3 A 6600A30003C 4 A 3090A10001J 5 A 6877A30013B 6 A 4994A20012A 7 A 6871A10016A 8 A 0CZZA20001Q BASE ASSY WELD SINGLE BARRIER ASSY SWITCH ASSY MICRO CABINET LEAD WIRE ASSY CONTROLBOX SINGLE PWB ASSY MAIN CAPACITOR 10 A 6631AQ3132U 11 A 5230AD3005A 12 A 3530A10006F 13 A 4838A20005A 14 A 3831A20016A 15 A 3551A30030A CONNECTOR ASSY FILTER AIR GRILLE FRONT...

Page 12: ...numberno _tt the position number CYCLE PARTS 6 B 4 B 3 B POS NO PART NO DESCRIPTION 1 B 5900A20007A FAN 2 B 4999A10001A SHROUD ASSY 3 B 4681A20040A MOTOR ASSY SINGLE 4 B 4960A20009A MOUNT MOTOR 5 B 5403A10008B CONDENSER ASSY 6 B 5421A10009B EVAPORATOR ASSY 12 ...

Page 13: ...7A NUT TERMINAL COVER 2 C 3550 CL001 D TERMINAL COVER 3 C 4970U L002A SPRING O L P 4 C 6750U L035A O L P 5 C 4986U L001 B GASKET 6 C 2520UABC2FA COMPRESSOR 7 C 1NHA0801206 NUT HEXAGON I 8 C 4810AR4155A BRACKET WASHER 9 C 4830A30005A BUSHING 10 C 5211A20237A TUBE ASSY SUCTION 11 C 5211A10070B TUBE ASSY DISCHARGE 12 C 5211A10085B TUBE ASSY CAPILLARY 13 ...