Summary of Contents for QUIET COMFORT 758.144131

Page 1: ...13 Model No 758 144131 FOR YOUR SAFETY READ ALL INSTRUCTIONS CAREFULLY QUIETCOMFORT WHOLE HOUSE HUMIDIFIER 12 Gallon Output Innovative Twin Fan Technology J Operating Instructions Parts List Sears Roebuck and Co Hoffman Estates IL 60179 U S A Part No SP6302 Printed in Canada ...

Page 2: ...re cleaning or whenever the humidifier is not in service 4 Keep the humidifier clean 5 Do not put foreign objects inside the humidifier Table of Contents 6 Never use your humidifier while any parf is missing or damaged in any manner 7 To reduce the risk of electrical hazard or damage to humidifier do not tilt jolt or tip humidifier while unit is running 8 To reduce the risk of damage to humidi fie...

Page 3: ... Speeds Filters Fill Light Auto Humidistat Auto Shut Off Controls CUL Listed AHAM Certified Volts Hertz Amps Watts Gallon OutputJ24 Hrs Water Reservoir Capacity Sq Ft Coverage 42 14413 12 5 Gallons 2500 3 4 42 14912 Yes Yes Yes Rotary Yes Yes 120 A C 60 2 28 130 Based on an area with average insulation and an 8 foot ceiling height ...

Page 4: ... circumstances should you use water I treatment products designed for Roto be t or U trason c hum d f ers Humidified Air is Then Released Through the Top Dry Air Enters Through Rear the k t1 _1 CAUTION Keep your humidifier clean While humidifiers do not cause colds some studies suggest that dirty humidifiers can cause cold like symp toms In some people To reduce the risk of this we recommend you c...

Page 5: ...se to a window condensation may form on the window pane If this is not appropriate the unit should be repositioned in another location NOTE Due to release of cool moist air from humidifier if is best to direct air away from home thermostat and hot air regis ters It is best to position humidifier next to an inside wall Hot air registers and cold air from outside walls can affect the effi ciencies o...

Page 6: ... wet let them dry completely and have unit checked by an authorized service per sonnel before plugging in This humidifier is designed to be filled using a bucket fill method The unit should be positioned where it will be operating To fill the 12 gallon humidifier close the con trol cover and open the pivoting lid Notice the splash guard inside the cabinet of the humidifier Use recommended mixture ...

Page 7: ...walls Humidity Control setting should be lowered until condensation no longer forms Speed Control _ Your Kenmore humidifier has a three speed rotary fan control The higher the air flow speed the more water is evaporated and released into the air Low speed 1 is the quietest and is provided for conditions that may not require as high an evapora tion rate Fill Light When the unit has a small amount o...

Page 8: ...p 4 If humidifier stops running and the Fill Light is not illuminated the humidity level is at the normal requirements for that setting or it is adjusting to the home conditions The table below shows recommended indoor humidity levels The figure below shows approximate relative humidity percentages which correspond to the various settings of the Humidity Control Recommended When Outdoor Indoor Rel...

Page 9: ...he fan assembly by opening the pivoting lid Grasp the fan assem bly front center and rear center Lift off and set aside on a clean flat surface The filler housing assemblies are now accessible NOTE There are two filter housing assemblies Each assembly con elata of a top filter housing and a front filter housing The front filter housing contains tabs that secure the top filter housing Do not remove...

Page 10: ...t filter Tab on housings Front Filter C Position fan assembly onto the cabi Houslna net Make sure the fan venturi low est cylinder section below the fan is placed inside the top filter housings d Close the pivoting lid on the fan assembly e The unit is ready for use or to be stored away for next season Float Retainer Top Filter _ Housing oat Front of Humidifier top view 10 ...

Page 11: ... not un plugged fan could start after housing Is removed Step 2 To Remove Parts a Remove the fan assembly by opening the pivoting lid Grasp the fan assem bly front center and rear center Lift off and set aside on a clean fiat surface b Before removing the internal parts of the humidifier cabinet we recommend moving the humidifier to an area where flour coverings are not susceptible to water damage...

Page 12: ...Fottow Bi Weekly Maintenance instructions at end of humidification season 2 Remove and throw away filters 3 Let humidifier dry completely before storing Do not store with water inside cabinet 4 Store in cool dry location 5 Install new fitters in clean humidifier before next season begins 6 Bi Weekly Maintenance is also rec ommended if you de not plan to use the humidifier for one week or more Disi...

Page 13: ...tting if desired Check 120 volt source for power Free float from obstruction Slide float retainer down to lowest positionin slot at back of cabinet Refer to Manual Dryout section on page 7 A small amount of water will remain in cabinet after fill light comes on Change to fresh new filters Deflect fill water off the splash guard Do not overfillpast Full labels in cabinet CAUTION Use only 42 14900 E...

Page 14: ......

Page 15: ... Cabinet Rail Kick Standard Hardware Item May be purchased locally Key I Part No No 16 STD601107 17 828515 16 42 14912 19 828194 20 828195 21 628534 22 828115 24 822406 1 25 824120 26 826367 27 STD610603 SP6302 Description Screw Pan Hal Ty AB 19 x 3 4 Caster Twin Wheel i F tter Evaporative Housing Top Filter Housing Front Filter Support Motor Motor Includesmountinghardware Fan Cord w Plug Retainer...

Page 16: ... For informationon purchasing a Sears MaintenanceAgreementor to inquire about an existingAgreement Call 9 am 5 pm Monday Saturday 1 800 827 6655 SEARS 4rr_dca s Repair Speclaf_f The model numberwill be foundon the Humidifier identificationlabel When requestingservice or ordering parts always providethe tallowing information ProductType Model Number Part Number Part Description 2000 Emerson Electri...