background image

sa850_a20_inst_eng_40.doc 

 
 
 
Daily use 

Daily use is very simple: 
Enter the code and open door.

 

 
Configure / Change User Codes 

P

 [b or s] [yy] [z] [e] 

P

 or 

 

b=programcode, s=systemcode (8 digits) 
yy = address 
z = user code (def. in ‘Code length’) 
e = max usage (if none entered there are no limits) 
 
Finishing: 

P

: Code is configured as an A-code (Access but only if by-passed) 

: Code is configured as an AB-code (Access and By-pass) 

If further codes must be configured the procedure can continue with 

yy

If configuration is done terminate with 

P

 or 

 
Delete user codes 

[b or s] [yy] 

P

 

 
x = program code 
yy = address

 

 
Delete 

all user codes 

[b or s] 

P 12 0000 P

 

 
System– and program code are not affected. Only user code are deleted.

 

 
 
 
 
 
 
 

Mounting 

SA850 mounts with only 2 screws on flat building surface

 

 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 

 

 
 

DON’T FORGET DIODE ON INDUCTIVE LOADS!!!!

 

 

 
 
 
 
 
 

 
 
 
 

Reset to factory settings 

Reset to factory settings following below steps:

 

 
 
 

SA850 is now reset to factory settings and all codes are cleared.

 

 
Specifications 

Power supply

 

8V to 24V DC

 

Current consumption

 

typical 40mA

 

Access output

 

open collector, max 1A, 24V

 

By-pass output

 

  isolated, max100mA, 25 ohm, 50V

 

Bell output

 

open collector, max 1A, 24V

 

Thread alarm output

 

open collector, max 1A, 24V

 

Sabotage loop

 

  isolated, max100mA, 25 ohm, 50V

 

Serial output

 

RS232, RS485, Wiegand, ABA, 

 

User code memory

 

100 key codes

 

By-pass time

 

on/off or 1 to 999 seconds

 

Access time

 

on/off or 1 to 999 seconds

 

Thread alarm time

 

3 seconds

 

Wire

 

10’ (3 m), 14-lead

 

Dimensions (H-W-D)

 

0.59in-1.93in-0.59in (150mm-49mm-15mm)

 

Weight

 

10.2oz (286g)

 

Operating temperatures

 

-30

°

F to 150

°

F (-35

°

C to 65

°

C)

 

Operating humidity

 

0%-100%

 

 
 
All specs are subject to change without prior notice. Latest information is available on www.keyseven.com. 

Mark the 4 drilling holes with the 
drill guide and drill the holes 
according to the wall material. 

Fasten the nylon reflector. 

Guide the cable trough the hole in 
the wall and fasten screws loosely. 

S

A

8

5

0

 i

s

 d

e

li

v

e

re

d

 w

it

h

 3

 m

e

te

rs

 o

fl

e

x

ib

le

 

1

4

-c

o

re

 w

ir

e

:

 

Red

 

8-24V DC

 

Back

 

Ground. 0V

 

Yellow

 

Access output. Open collector - "Makes a ground" when output is activated.

 

Green/White

 

By-pass output, wire 1. Isolated output.

 

Green/Brown

 

By-pass output, wire 2. Isolated output.

 

Blue

 

Sabotage loop, wire 1. Isolated output.

 

Blue/Red

 

Sabotage loop, wire 2. Isolated output.

 

Green

 

Bell output. Open collector - "Makes a ground" when output is activated.

 

Violet

 

Thread alarm output. Open collector - "Makes a ground" when output is activated.

 

Grey/Pink

 

RS485 data, A

 

Grey

 

RS485 data, B

 

White

 

Status indicator input. Connects to a central unit that signals its (by-pass) state.

 

Pink

 

Buzzer. Can be used to externally control the buzzer.

 

Brown

 

-

 

Connect SA850 wires appropriate and test tamper circuit with function 42 (

Sabotage 

test). Tighten screws. 

Clean key surface. Remove adhesive protection from front cover foil and place it 
carefully on the SA850. 

1:

 

Disconnect power supply and network wires

 

2:

 

Connect Pink wire (buzzer) to Black wire (ground)

 

3:

 

Re-connect power and wait 5 sec until red LED lights up

 

4:

 

Release Pink wire (buzzer) from Black wire (ground) within 5 
sec.

 

 

 

 

 

SA850-A20 

INSTALLATIONS MANUAL 

Rev. 4.0 

 

 

ACCESS CONTROL 

 

BY-PASS 

 

STAND ALONE + NETWORK 

 

SILENT ALARM 

 

SKAFOR cl. 3 approved 

 

SA850-A20

 is both access control and by-pass switch with individual outputs. 

SA850-A20

 isolated by-pass output and 1A open collector access output 

SA850-A20

 has up to 100 user codes. 

SA850-A20

 mounts easily on any building surface. 

SA850-A20

 tools make it easy to configure the unit. 

SA850-A20

 networks with other SA850’s and PC (supervision/control). 

SA850-A20

 can be programmed from the keypad or from a PC. 

SA850-A20

 ‘clickable’ keys, 3 bright LED’s and multi-tone buzzer. 

SA850-A20

 buzzer and LED’s are externally controllable. 

SA850-A20

 has a separate output for thread alarm (secret code). 

SA850-A20

 has a bell button with dedicated output. 

SA850-A20

 has input for EXIT-button. 

SA850-A20

 outputs are programmable to work as timer or toggle. 

SA850-A20

 can be connected to PC or printer for log function. 

SA850-A20

 has optical sensor for sabotage sensing. 

SA850-A20

 uses latest FLASH-technology 

SA850-A20

 is also available with prox reader (SA850-A30). 

 

 

 

 

 

Reviews: