Page 1: ...i es 2 IMPORTANT Save for local electrical inspector s use Installer Leave installation instructions with the homeowner Homeowner Keep installation instructions for future reference IMPORTANT conserver pour consultation par I inspecteur local des installations electriques Installateur Remettre les instructions d installation au proprietaire Propri_taire Conserver les instructions d installation po...

Page 2: ...Installation de la bride antibasculement 30 Retrait du tiroir rechaud 31 Verification de I emplacement de la bride antibasculement 31 R_glage de I aplomb de la cuisini e 31 Raccordement la canalisation de gaz 31 Syst_me d allumage 61ectronique 33 Reinstallation des grilles du four et du tiroir r6chaud 34 Achever I installation 34 CONVERSIONS POUR CHANGEMENT DE GAZ 34 Conversion pour I alimentation...

Page 3: ...pplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier In the State of Massachusetts the following installation instructions apply Installations and repairs must be performed by a qualified or licensed contractor plumber or gasfitter qualified or licensed by the State of Massachusetts If using a ball valve it shall be ...

Page 4: ...flooring may require longer mounting screws to anchor bracket to subfloor Longer mounting screws are available from your local hardware store Parts needed Check local codes and consult gas supplier Check existing gas supply and electrical supply See Electrical Requirements and Gas Supply Requirements sections IMPORTANT Observe all governing codes and ordinances Do not obstruct flow of combustion a...

Page 5: ...ards CAN CSA A240 1atest edition or with local codes Mobile home installations require When this range is installed in a mobile home it must be secured to the floor during transit Any method of securing the range is adequate as long as it conforms to the standards listed above Four wire power supply cord or cable must be used in a mobile home installation The appliance wiring will need to be revis...

Page 6: ...rance to top of the cooktop see NOTE E 30 76 2 cm rain opening width F This shaded area recommended for installation of rigid gas pipe G 6 15 2 cm available area for gas and electric installation H This shaded area recommended for installation of outlet or junction box LZ 17 8cm J 1_ 2 3 3 cm K 4W 11 4 cm L 5 12 7 cm min clearance from both sides of the range to the side wall or other combustible ...

Page 7: ...93 mm diameter connection opening A time delay fuse or circuit breaker is recommended The range can be connected directly to the fused disconnect or circuit breaker box through flexible or nonmetallic sheathed copper or aluminum cable See Electrical Connection Allow 2 to 3 ft 61 0 cm to 91 4 cm of slack in the line so that the range can be moved if servicing is ever necessary A UL listed conduit c...

Page 8: ...connected to LP have a qualified person make sure gas pressure does not exceed 14 36 cm water column Examples of a qualified person include licensed heating personnel authorized gas company personnel and authorized service personnel Failure to do so can result in death explosion or fire Observe all governing codes and ordinances IMPORTANT This installation must conform with all local codes and ord...

Page 9: ...essure testing of the gas supply piping system at test pressures equal to or less than 1t2psi 3 5 kPa Must include a shutoff valve The supply line must be equipped with a manual shutoff valve This valve should be located in the same room but external to the range It should be in a location that allows ease of opening and closing Do not block access to shutoff valve The valve is for turning on or s...

Page 10: ...k on the cardboard corners 3 Pull cardboard bottom firmly to remove Slide In Ranges 1 Measure the distance of the countertop to the floor Measure at all 4 locations corresponding to the 4 corners of the underside of the range cooktop as shown A Distance from the floor to C Cooktop surface underside of range cooktop D Range side frame B Grate 3 Your leveling height will be the difference between th...

Page 11: ...oard or hardboard 1 Remove template from the anti tip bracket kit found inside the oven cavity or from the back of this manual 2 Place template on the floor in cabinet opening so that the left edge is against cabinet and top edge is against rear wall molding or cabinet 3 Tape template into place 4 If countertop is not flush with cabinet opening edge align template with overhang If cabinet opening ...

Page 12: ...bracket is installed Look for the anti tip bracket securely attached to floor Slide range back so rear range foot is under anti tip bracket 2 If installing the range in a mobile home you must secure the range to the floor Any method of securing the range is adequate as long as it conforms to the standards in the Location Requirements section Place rack in oven Place level on rack and check levelne...

Page 13: ...1 2 Disconnect power Remove the terminal block cover screws located on the back of the range Pull cover down and toward you to remove coveE A Hold down screws B Terminal block cover Feed the power supply cord behind the black horizontal cross brace and through the strain relief allowing enough slack to easily attach the wiring to the terminal block A Black horizontal cross brace B Power supply cor...

Page 14: ...ly cord 4 wire direct A fused 4 wira connection disconnect or Direct wire circuit breaker 12 7 cm box 3 wira receptacle NEMA type 10 50R A UL listed 250 volt minimum 40 amp range power supply cord 3 wira connection Power supply cord 3 wire direct A fused 3 wire connection 1 disconnect or Direct wire circuit breaker box 4 wire connection Power Supply Cord Use this method for New branch circuit inst...

Page 15: ...th screw 3 wire connection Power Supply Cord Use this method only if local codes perrnit connecting cabinet ground conductor to neutral wire of power supply cord 1 Use a 1 nut driver and remove the hex washer head screws from the aluminum terminal blocks 2 Connect the neutral center wire to the center terminal connector using one of the hex washer head screws Securely tighten screw o t ttt lTil J ...

Page 16: ...er head screws and insert the neutral white wire under the screw clamp at the bottom of the center position terminal connector A Insert wire under screw clamp B Hex washer head screw 3 Securely tighten the hex washer head screws to 35 Ibs in 4 0 N m minimum torque to make a proper electrical connection 4 Tighten the locking ring of the conduit connector 5 Replace the terminal block cover with scre...

Page 17: ...l connections by brushing on an approved noncorrosive leak detection solution If bubbles appear a leak is indicated Correct any leak found 3 Remove cooktop burner caps and grates from parts package Align notches in burner caps with pins in burner base Burner caps should be level when properly positioned If burner caps are not properly positioned surface burners will not light A Burner base B Burne...

Page 18: ...ment locations shown in the following illustration and engage the slotted screw Turn the screw until the flame is the proper size A Simmer burner regulation B Power burner regulation 3 Replace the control knob 4 Test the flame by turning the control from LO to HI checking the flame at each setting Repeat start up If a burner does not light at this point turn control knobs to Off and contact your d...

Page 19: ...rvice personnel Failure to do so can result in death explosion or fire To Convert Gas Pressure Regulator 1 Turn manual shutoff valve to the closed position 2 Unplug range or disconnect power B A To range B Manual shutoff valve closed position C Gas supply line 3 Remove warming drawer See the Remove Warming Drawer section for instructions Locate gas pressure regulator at rear of warming drawer comp...

Page 20: ...orifice spuds in plastic parts bag for future use and keep with literature package 6 Replace burner cap 7 Repeat steps 1 6 for the remaining burners except for the TripleTier Flame burner on some models See To Convert TripleTier Flame Burners section To Convert TripleTier _ Flame Burners on some models 1 Remove burner cap 2 Remove the burner head using a size T20 TORX _screwdriver 3 Remove the pla...

Page 21: ...to the closed position 2 Unplug range or disconnect power A i A Torange B Manual shutoff valve closed position C Gassupply line 3 Remove warming drawer See the Remove Warming Drawer section for instructions Locate gas pressure regulator at rear of warming drawer compartment 4 Remove access cover from the gas pressure regulator A _ _ ____ A Gas pressure regulator IMPORTANT Do not remove the gas pre...

Page 22: ..._ B __ A Plate B External gas office spud C Internal gas orifice spud 4 Apply masking tape to the end of a 7 mm nut driver to help hold the internal gas orifice spud in the nut driver while changing it Press nut driver down onto the internal gas orifice spud and remove by turning it counterclockwise and lifting out Set internal gas orifice spud aside 5 Use a 7 mm combination wrench to remove the e...

Page 23: ... les renseignements dans ce manuel ne sont pas exactement observes un incendie ou une explosion peut survenir causant des dommages au produit des blessures ou un d4cbs Ne pas entreposer ni utiliser de I essence ou d autres vapeurs ou liquides inflammables proximit4 de cet appareil ou de tout autre appareil _lectromenager QUE FAIRE DANS LE CAS D UNE ODEUR DE GAZ Ne pas tenter d allumer un appareil ...

Page 24: ...glements en vigueur Ne pas obstruer le flux de combustion et la ventilation C est a rinstallateur qu incombe la responsabilite de respecter les distances de separation exigees specifiees sur la plaque signaletique de I appareil La plaque signaletique est situee sur le cete droit de la garniture de la porte du four Chaque bride dolt etre solidement fixee au sous plancher L epaisseur du materiau du ...

Page 25: ...pulations de la version la plus r6cente de la norme CAN CSA A240 ou des codes Iocaux en vigueur Autree crit_res a respecter pour une installation en residence mobile Dans le cas de I installation de cette cuisiniere dans une r6sidence mobile la cuisiniere dolt 6tre fix6e au plancher durant tout d placement du v6hicule Toute m6thode de fixation de la cuisiniere est ad6quate dans la mesure oQ elle s...

Page 26: ...ale vers la partie superieure de la table de cuisson voir la REMARQUE E Largeur de I ouverture 30 76 2 cm rain F Installation de la canalisation de gaz rigide recommand_e dans cette zone ombree G 6 15 2 cm disponible pour I instailation du gazet de 1 61ectricit6 H Installation de la prise ou de la boite de connexion dans cette zone ombree I 7 17 8 cm J IV2 3 8 cm K 4 11 4cm L D gagement de 6 12 7 ...

Page 27: ...ale de la cuisini_re Ne pas utiliser de cable de rallonge Risque d explosion Utiliser une canalisation neuve d arriv_e de gaz approuv_e par la CSA International Installer un robinet d arr6t Bien serrer chaque organe de connexion de la canalisation de gaz En cas de connexion au gaz propane demander b une personne qualifide de s assurer que la pression de gaz ne d_passe pas 36 cm 14 po de la colonne...

Page 28: ...ement alignee Pressurisation _ une pression superieure a 1 2Ib po 2 14 colonne d eau Lors de tout test de pressurisation de ce syst_me une pression superieure _ _ Ib po 2 3 5 kPa on doit deconnecter I appareil et son robinet d arret individuel de la oanalisation de gaz Pressurisation a une pression inferieure V2 Ib po 2 14 colonne d eau Lors de tout test de pressurisation de la canalisation de gaz...

Page 29: ...ins de protection 3 Tirer fermement sur la partie inf ieure du carton pour le retirer Cuisini_res encastr_es 1 Mesurer la distance du plan de travail jusqu au sol Mesurer aux 4 emplacements correspondant aux 4 coins de la partie inf ieure de la table de cuiseon tel qu illustr A Distance en partant du sol vets la pattie inferieure de la table de cuisson B Grille C Surface de la table de cuisson D C...

Page 30: ...er la bride antibasculement Avant de faire glisser la cuisini_re _ son emplacement final v6rifier qu il sera possible de faire glisser la bride antibasculement sous la cuisini_re et sur le pied de nivellement arri_re avant I installation de la bride antibasculement Contacter un installateur de rev_tements de sol quaiifie au sujet des meilleures methodes de per age des trous de montage travers le r...

Page 31: ...r I avant le retirer completement et doucemeet IMPORTANT Sur les modeles equipes d un tiroir rechaud le pied arri e de la cuisiniere doit etre visible de I avant et legerement d ue c6te de la ouisiniere 1 Verifier I installation de la bride antibasculemeet Verifier que la bride antibasculement est solidement fix6e au sol Faire glisser la cuisiniere vers I arriere veiller placer le pied arriere sou...

Page 32: ...arr_t form6 B Robinet d arr_t ouvert 2 Effectuer une recherche des fuites appliquer au pieceau sur les coneexions une solution non corrosive de d6tection des fuites la formation de bulles identifiera une fuite 121iminer toute fuite constat6e 3 Prendre les chapeaux de breleur et grilles de breleur dans le paquet de pi_ces Aligner les encoches des chapeaux de breleur avec les broches dans la base de...

Page 33: ...a table de cuisson _ la position d arr6t V6rifier que la cuisini6re est branch6e et correctement aliment_e fusible grill6 disjoncteur ouvert V6rifier que chaque robinet d arr6t est ouvert V6rifier que le chapeau de brQleur est correctement plac6 sur la base du brQleur R6p6ter le processus de mise en marche Si ce point un breleur ne s allume pas tourner les boutons de commande Off arr6t et contacte...

Page 34: ... four et contacter un 61ectricien qualifi Prise de courant correctement aliment6e Consulter la section Depannage dans le Guide d utilisation et d entretien 1 Verifier que toutes les pi_ces sont maintenant install6es S il reste une pi6ce passer en revue les differentes etapes pour decouvrir laquelle aurait 6te oubliee 2 V6rifier la presence de tousles outils Apr6s 5 minutes de fonctionnement de la ...

Page 35: ...de 7 mm pour retenir le gicleur dans le tourne ecrou durant I op ation Appuyer pour engager le tourne ecrou sur le gicleur faire tourner le gicleur dans le sens antihoraire puis soulever pour I enlever conserver le gicleur A Electrode d allumage B Ouverture du tube de gaz C Chapeau de brOleur D Base de brQleur 4 Chaque gicleur est marque d un chiffre grave et d un point colore et comporte une rain...

Page 36: ...r01eurs a flamme TripleTier e Position du brOleur Capacite Couleur Taille thermique du br01eur C6te avant gauche 11 800 BTU h Marron 1 mm brQleur externe TripleTier _ C6t6 avant gauche 2 200 BTU h Orange 0 42 mm brQleur interne TripleTier _ 7 Reinstaller les composants du brQleur plaque tete et chapeau 8 Placer les gicleurs pour gaz naturel dans le sachet de plastique pour reutilisation ulterieure...

Page 37: ...u de I ouverture d acc6s faire tourner le chapeau dans le sens antihoraire 6 Oter la but6e de ressort qui se trouve sous le chapeau pousser contre le c6t6 plat de la but6e de ressort Examiner la but6e de ressort pour identifier la position LP ou NAT 7 Orienter correctement la but6e de ressort pour que la mention NAT soit au fond 8 R6installer la but6e de ressort dans le chapeau 9 R6installer le ch...

Page 38: ...te d un tourne ecrou de 7 mm pour retenir le gicleur interne dans le tourne ecrou durant I op6ration Appuyer pour engager le tourne ecrou sur le gicleur faire tourner le gicleur dans le sens antihoraire puis soulever pour I enlever conserver le gicleur part 5 Utiliser une cle mixte de 7 mm pour enlever le gicleur externe Faire tourner le gicleur dans le sens antihoraire conserver le gicleur part 6...

Page 39: ...t edge against rear wall Couper ici et placer le rebord superieur contre le c6te gauche du placard et le rebord droit contre la paroi arri_re F Use this template to anchor the left rear leg of range Utlliser ce gabarit pour ancrer le pied arribre gauche de la cuisinibre ANTFTOP BRACKET Holes in bracket _ rous dans la bride Q 39 ...

Page 40: ...stered Trademark TM Trademark of KitchenAid U S A KitchenAid Canada licensee ill Canada Printed in U S A Tous droits reserves Marque depos_eFrMMarque de commerce de KitchenAid U S A Emploisous licence par KitchenAid Canadaau Canada Imprime aux E U ...

Reviews: